Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study

被引:1
|
作者
Su, Shi [1 ,2 ]
Hu, Jiahao [1 ,2 ]
Ding, Ye [1 ,2 ]
Zhang, Junhao [1 ,2 ]
Lau, Vick [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
brain; magnetic resonance angiography; MRI; neck; noncontrast enhancement; time-of-flight; ultra-low-field; THIN SLAB ACQUISITION; MR-ANGIOGRAPHY; NOISE-RATIO; TOF-MRA; DISEASE; VOLUME;
D O I
10.1002/nbm.5213
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents. The preliminary feasibility of TOF MRA at 0.05 T was demonstrated for the first time despite the extremely low MR signal. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. image
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Quiescent interval low angle shot magnetic resonance angiography of the extracranial carotid arteries
    Koktzoglou, Ioannis
    Murphy, Ian G.
    Giri, Shivraman
    Edelman, Robert R.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 2072 - 2077
  • [22] Ultra-low noise graphene/copper/nylon fabric for electromagnetic interference shielding in ultra-low field magnetic resonance imaging
    Yu, Mengmeng
    Tao, Quan
    Dong, Hui
    Huang, Tao
    Li, Yongqiang
    Xiao, Yi
    Yang, Siwei
    Gao, Bo
    Ding, Guqiao
    Xie, Xiaoming
    JOURNAL OF MAGNETIC RESONANCE, 2020, 317
  • [23] Ultra-high field (7T) functional magnetic resonance imaging in amyotrophic lateral sclerosis: a pilot study
    Barry, Robert L.
    Babu, Suma
    Anteraper, Sheeba Arnold
    Triantafyllou, Christina
    Keil, Boris
    Rowe, Olivia E.
    Rangaprakash, D.
    Paganoni, Sabrina
    Lawson, Robert
    Dheel, Christina
    Cernasov, Paul M.
    Rosen, Bruce R.
    Ratai, Eva-Maria
    Atassi, Nazem
    NEUROIMAGE-CLINICAL, 2021, 30
  • [24] Moyamoya Vessel Pathology Imaged by Ultra-High-Field Magnetic Resonance Imaging at 7.0 T
    Dengler, Nora F.
    Madai, Vince I.
    Wuerfel, Jens
    von Samson-Himmelstjerna, Federico C.
    Dusek, Petr
    Niendorf, Thoralf
    Sobesky, Jan
    Vajkoczy, Peter
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2016, 25 (06) : 1544 - 1551
  • [25] Applications of Ultra-Low Field Magnetic Resonance for Imaging and Materials Studies
    Espy, Michelle
    Flynn, Mark
    Gomez, John
    Hanson, Christina
    Kraus, Robert
    Magnelind, Per
    Maskaly, Karlene
    Matlashov, Andrei
    Newman, Shaun
    Peters, Mark
    Sandin, Henrik
    Savukov, Igor
    Schultz, Larry
    Urbaitis, Algis
    Volegov, Petr
    Zotev, Vadim
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 835 - 838
  • [26] Quantitative magnetic resonance angiography as a potential predictor for cerebral hyperperfusion syndrome: a preliminary study
    Andereggen, Lukas
    Amin-Hanjani, Sepideh
    El-Koussy, Marwan
    Verma, Rajeev K.
    Yuki, Kenya
    Schoeni, Daniel
    Hsieh, Kety
    Gralla, Jan
    Schroth, Gerhard
    Beck, Juergen
    Raabe, Andreas
    Arnold, Marcel
    Reinert, Michael
    Andres, Robert H.
    JOURNAL OF NEUROSURGERY, 2018, 128 (04) : 1006 - 1014
  • [27] Automated detection of intracranial artery stenosis and occlusion in magnetic resonance angiography: A preliminary study based on deep learning
    Qiu, Jinming
    Tan, Guanru
    Lin, Yan
    Guan, Jitian
    Dai, Zhuozhi
    Wang, Fei
    Zhuang, Caiyu
    Wilman, Alan H.
    Huang, Huaidong
    Cao, Zhen
    Tang, Yanyan
    Jia, Yanlong
    Li, Yan
    Zhou, Teng
    Wu, Renhua
    MAGNETIC RESONANCE IMAGING, 2022, 94 : 105 - 111
  • [28] Non-enhanced versus low-dose contrast-enhanced renal magnetic resonance angiography at 7 T: a feasibility study
    Laader, Anja
    Beiderwellen, Karsten
    Kraff, Oliver
    Maderwald, Stefan
    Ladd, Mark E.
    Forsting, Michael
    Umutlu, Lale
    ACTA RADIOLOGICA, 2018, 59 (03) : 296 - 304
  • [29] Preliminary Study on the Application of Ultrahigh Field Magnetic Resonance in Moyamoya Disease
    Su, Jiabin
    Ni, Wei
    Yang, Baofeng
    Xiao, Weiping
    Gao, Xinjie
    Yang, Heng
    Li, Yanjiang
    Lei, Yu
    Jiang, Hanqiang
    Wang, He
    Gu, Yuxiang
    Mao, Ying
    OXIDATIVE MEDICINE AND CELLULAR LONGEVITY, 2021, 2021
  • [30] Feasibility of magnetic resonance redox imaging at low magnetic field: comparison at 1 T and 7 T
    Nakamura, Mizuki
    Shibata, Sayaka
    Yamasaki, Toshihide
    Ueno, Megumi
    Nakanishi, Ikuo
    Matsumoto, Ken-ichiro
    Kamada, Tadashi
    Yamada, Ken-ichi
    Aoki, Ichio
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2017, 9 (10): : 4481 - 4491