Analytical Validation of a Volumetric Absorptive Microsampling Method for Therapeutic Drug Monitoring of the Oral Targeted Anticancer Agents, Abiraterone, Alectinib, Cabozantinib, Imatinib, Olaparib, and Sunitinib, and Metabolites

被引:2
作者
Meertens, Marinda [1 ]
de Vries, Niels [1 ]
Rosing, Hilde [1 ]
Steeghs, Neeltje [2 ]
Beijnen, Jos H. [1 ,3 ]
Huitema, Alwin D. R. [1 ,4 ,5 ]
机构
[1] Antoni Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Pharm & Pharmacol, Amsterdam, Netherlands
[2] Antoni Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Med Oncol, Amsterdam, Netherlands
[3] Univ Utrecht, Utrecht Inst Pharmaceut Sci, Div Pharmacoepidemiol & Clin Pharmacol, Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dept Clin Pharm, Utrecht, Netherlands
[5] Princess Maxima Ctr Pediat Oncol, Dept Pharmacol, Utrecht, Netherlands
关键词
volumetric absorptive microsampling; therapeutic drug monitoring; LC-MS/MS; oral targeted anticancer drugs; QUANTITATIVE BIOANALYSIS; KINASE INHIBITORS; HEMATOCRIT; EXTRACTION; BIAS;
D O I
10.1097/FTD.0000000000001175
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Supplemental Digital Content is Available in the Text. Background:Volumetric Absorptive Microsampling (VAMS) is a useful tool for therapeutic drug monitoring (TDM) of oral targeted anticancer agents. VAMS aims to improve safety and efficacy by enabling at-home blood sample collection by patients. This study aimed to develop and validate an ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitative determination of abiraterone, alectinib, cabozantinib, imatinib, olaparib, sunitinib, and the metabolites, Delta(4)-abiraterone (D4A), alectinib-M4, imatinib-M1, and N-desethyl sunitinib, in dried whole blood samples using VAMS to support TDM.Methods:After the collection of 10 mu L of whole blood sample using the VAMS device, the analytes were extracted from the tip using methanol with shaking, evaporated, and reconstituted in acetonitrile:0.1 mol/L ammonium hydroxide in water (1:1, vol/vol). The extracts were then analyzed using ultra-high performance liquid chromatography-tandem mass spectrometry. Validation experiments based on the ICH M10 guideline were carried out, and stability was evaluated under shipping and storage conditions. VAMS specimens were collected in the outpatient clinic to demonstrate the applicability of the assay.Results:The validated range of the method was considered accurate and precise for all analytes. Accordingly, the validation experiments met the relevant requirements, except for cross-analyte interference. Based on the stability data, shipment can be performed at room temperature within 14 days after sample collection and the VAMS specimen can be stored up to 9 months at -20 and -70 degrees C. Samples from 59 patients were collected at the hospital.Conclusions:The developed method could be used to successfully quantify the concentrations of abiraterone, D4A, alectinib, alectinib-M4, cabozantinib, imatinib, imatinib-M1, olaparib, sunitinib, and N-desethyl sunitinib within the validated range using VAMS. Therefore, the method can be used to estimate the dried whole blood-to-plasma ratios for TDM in the clinic.
引用
收藏
页码:494 / 502
页数:9
相关论文
共 34 条
  • [1] Analytical challenges in quantifying abiraterone with LC-MS/MS in human plasma
    Benoist, Guillemette E.
    van der Meulen, Eric
    Lubberman, Floor J. E.
    Gerritsen, Winald R.
    Smilde, Tineke J.
    Schalken, Jack A.
    Beumer, Jan H.
    Burger, David M.
    van Erp, Nielka P.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (11)
  • [2] Development and validation of an integrated LC-MS/MS assay for therapeutic drug monitoring of five PARP-inhibitors
    Bruin, M. A. C.
    de Vries, N.
    Lucas, L.
    Rosing, H.
    Huitema, A. D. R.
    Beijnen, J. H.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1138 (1138):
  • [3] Official International Association for Therapeutic Drug Monitoring and Clinical Toxicology Guideline: Development and Validation of Dried Blood Spot-Based Methods for Therapeutic Drug Monitoring
    Capiau, Sara
    Veenhof, Herman
    Koster, Remco A.
    Bergqvist, Yngve
    Boettcher, Michael
    Halmingh, Otto
    Keevil, Brian G.
    Koch, Birgit C. P.
    Linden, Rafael
    Pistos, Constantinos
    Stolk, Leo M.
    Touw, Daan J.
    Stove, Christophe P.
    Alffenaar, Jan-Willem C.
    [J]. THERAPEUTIC DRUG MONITORING, 2019, 41 (04) : 409 - 430
  • [4] Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study
    De Kesel, Pieter M. M.
    Lambert, Willy E.
    Stove, Christophe P.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 881 : 65 - 73
  • [5] Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis
    Denniff, Philip
    Spooner, Neil
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (16) : 8489 - 8495
  • [6] European Medicines Agency, ICH GUIDELINE M10 BI
  • [7] Therapeutic drug monitoring-based precision dosing of oral targeted therapies in oncology: a prospective multicenter study
    Groenland, S. L.
    van Eerden, R. A. G.
    Westerdijk, K.
    Meertens, M.
    Koolen, S. L. W.
    Moes, D. J. A. R.
    de Vries, N.
    Rosing, H.
    Otten, H.
    Vulink, A. J. E.
    Desar, I. M. E.
    Imholz, A. L. T.
    Gelderblom, H.
    van Erp, N. P.
    Beijnen, J. H.
    Mathijssen, R. H. J.
    Huitema, A. D. R.
    Steeghs, N.
    Dutch Pharmacology Oncology Grp DPOG
    [J]. ANNALS OF ONCOLOGY, 2022, 33 (10) : 1071 - 1082
  • [8] Efficacy and toxicity of vemurafenib and cobimetinib in relation to plasma concentrations, after administration via feeding tube in patients with BRAF-mutated thyroid cancer: a case series and review of literature
    Henegouwen, J. M. van Berge
    van der Wijngaart, H.
    Zeverijn, L. J.
    Hoes, L. R.
    Meertens, M.
    Huitema, A. D. R.
    Devriese, L. A.
    Labots, M.
    Verheul, H. M. W.
    Voest, E. E.
    Gelderblom, H.
    [J]. CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2022, 90 (01) : 97 - 104
  • [9] Quantification of 11 Therapeutic Kinase Inhibitors in Human Plasma for Therapeutic Drug Monitoring Using Liquid Chromatography Coupled With Tandem Mass Spectrometry
    Herbrink, Maikel
    de Vries, Niels
    Rosing, Hilde
    Huitema, Alwin D. R.
    Nuijen, Bastiaan
    Schellens, Jan H. M.
    Beijnen, Jos H.
    [J]. THERAPEUTIC DRUG MONITORING, 2016, 38 (06) : 649 - 656
  • [10] Clinically relevant drug interactions with multikinase inhibitors: a review
    Hussaarts, Koen G. A. M.
    Veerman, G. D. Marijn
    Jansman, Frank G. A.
    van Gelder, Teun
    Mathijssen, Ron H. J.
    van Leeuwen, Roelof W. F.
    [J]. THERAPEUTIC ADVANCES IN MEDICAL ONCOLOGY, 2019, 11