Aerosol Delivery Efficiency With High-Flow Nasal Cannula Therapy in Neonatal, Pediatric, and Adult Nasal Upper-Airway and Lung Models

被引:0
作者
DiBlasi, Robert M. [1 ,2 ,3 ]
Engberg, Rebecca J. [2 ]
Poli, Jonathan [2 ]
Carlin, Kristen E. [4 ]
Kontoudios, Niko [1 ,2 ]
Longest, Worth [5 ]
Kajimoto, Masaki [2 ]
机构
[1] Seattle Childrens Hosp, Resp Therapy Dept, Seattle, WA 98105 USA
[2] Seattle Childrens Res Inst, Ctr Resp Biol & Therapeut, Seattle, WA 98105 USA
[3] Seattle Childrens Hosp, Pediat Intens Care Unit, Seattle, WA 98105 USA
[4] Seattle Childrens Res Inst, Ctr Clin & Translat Res, Seattle, WA USA
[5] Virginia Commonwealth Univ, Dept Mech & Nucl Engn, Richmond, VA USA
关键词
system. high-flow nasal cannula; bronchodilator; aerosol delivery; lung dose; scintigraphy; vibrating mesh nebulizer; DRUG-DELIVERY; DEAD SPACE; DEPOSITION; PRESSURE; INFANT; VENTILATION; SIZE; JET;
D O I
10.4187/respcare.11286
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: High-flow nasal cannula (HFNC) systems employ different methods to provide aerosol to patients. This study compared delivery efficiency, particle size, and regional deposition of aerosolized bronchodilators during HFNC in neonatal, pediatric, and adult upper-airway and lung models between a proximal aerosol adapter and distal aerosol circuit chamber. METHODS: A filter was connected to the upper airway to a spontaneously breathing lung model. Albuterol was nebulized using the aerosol adapter and circuit at different clinical flow settings. The aerosol mass deposited in the upper airway and lung was quantified. Particle size was measured with a laser diffractometer. Regional deposition was assessed with a gamma camera at each nebulizer location and patient model with minimum flow settings. RESULTS: Inhaled lung doses ranged from 0.2-0.8% for neonates, 0.2-2.2% for the small child, and 0.5-5.2% for the adult models. Neonatal inhaled lung doses were not different between the aerosol circuit and adapter, but the aerosol circuit showed marginally greater lung doses in the pediatric and adult patient models. Impacted aerosols and condensation in the non-heated HFNC and aerosol delivery components contributed to the dispersion of coarse liquid droplets, high deposition (11-44%), and occlusion of the supine neonatal upper airway. In contrast, the upright pediatric and adult upper-airway models had minimal deposition (0.3-7.0%) and high fugitive losses ('24%) ' 24%) from liquid droplets leaking out of the nose. The high impactive losses in the aerosol adapter (56%) were better contained than in the aerosol circuit, resulting in less cannula sputter (5% vs 22%), fewer fugitive losses (18% vs 24%), and smaller inhaled aerosols (5 l m vs 13 l m). CONCLUSIONS: The inhaled lung dose was low (1-5%) during HFNC. Approaches that streamline aerosol delivery are needed to provide safe and effective therapy to patients receiving aerosolized medications with this HFNC system
引用
收藏
页码:1146 / 1160
页数:15
相关论文
共 50 条
  • [41] Noise Levels of Neonatal High-Flow Nasal Cannula Devices - An in-vitro Study
    Koenig, Kai
    Stock, Ellen L.
    Jarvis, Melanie
    NEONATOLOGY, 2013, 103 (04) : 264 - 267
  • [42] Comparison of a high-flow humidified nasal cannula to nasal continuous positive airway pressure in children with acute bronchiolitis: experience in a pediatric intensive care unit
    Metge, Prune
    Grimaldi, Celine
    Hassid, Sophie
    Thomachot, Laurent
    Loundou, Anderson
    Martin, Claude
    Michel, Fabrice
    EUROPEAN JOURNAL OF PEDIATRICS, 2014, 173 (07) : 953 - 958
  • [44] The Clinical Impact of Heated Humidified High-Flow Nasal Cannula on Pediatric Respiratory Distress
    Kawaguchi, Atsushi
    Yasui, Yutaka
    deCaen, Allan
    Garros, Daniel
    PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (02) : 112 - 119
  • [45] High-Flow Nasal Cannula and Aerosolized β Agonists for Rescue Therapy in Children With Bronchiolitis: A Case Series
    Morgan, Sherwin E.
    Mosakowski, Steve
    Solano, Patti
    Hall, Jesse B.
    Tung, Avery
    RESPIRATORY CARE, 2015, 60 (09) : E161 - E165
  • [46] High-flow nasal cannula therapy: clinical practice in intensive care units
    Besnier, Emmanuel
    Hobeika, Sinad
    NSeir, Saad
    Lambiotte, Fabien
    Du Cheyron, Damien
    Sauneuf, Bertrand
    Misset, Benoit
    Tamion, Fabienne
    Schne, Guillaume
    Richecoeur, Jack
    Maizel, Julien
    Girault, Christophe
    ANNALS OF INTENSIVE CARE, 2019, 9 (01)
  • [47] Humidification in Very-High-Flow Nasal-Cannula Therapy in an Adult Lung Model
    Chikata, Yusuke
    Morinishi, Keisuke
    Nishimura, Masaji
    RESPIRATORY CARE, 2019, 64 (07) : 809 - 817
  • [48] Comparison of aerosol delivery across combinations of drug delivery interfaces with and without concurrent high-flow nasal therapy
    Gavin Bennett
    Mary Joyce
    Elena Fernández Fernández
    Ronan MacLoughlin
    Intensive Care Medicine Experimental, 7
  • [49] Modalities and Complications Associated With the Use of High-Flow Nasal Cannula: Experience in a Pediatric ICU
    Baudin, Florent
    Gagnon, Sebastien
    Crulli, Benjamin
    Proulx, Francois
    Jouvet, Philippe
    Emeriaud, Guillaume
    RESPIRATORY CARE, 2016, 61 (10) : 1305 - 1310
  • [50] High-flow nasal cannula compared with continuous positive airway pressure: a bench and physiological study
    Vieira, Fernando
    Bezerra, Frank Silva
    Coudroy, Remi
    Schreiber, Annia
    Telias, Irene
    Dubo, Sebastian
    Cavalot, Giulia
    Pereira, Sergio Martins
    Piraino, Thomas
    Brochard, Laurent Jean