Occupational Radiation Dose Trends in US Radiologic Technologists Assisting with Fluoroscopically Guided Interventional Procedures, 1980-2020

被引:0
作者
Milder, Cato M. [1 ]
Borrego, David [2 ]
Preston, Dale L. [3 ]
Villoing, Daphnee [4 ]
Kwon, Tae-Eun [1 ]
Miller, Donald L. [5 ]
Alexander, Bruce H. [6 ]
Linet, Martha S. [1 ]
Lee, Choonsik [1 ]
Kitahara, Cari M. [1 ]
机构
[1] NCI, Radiat Epidemiol Branch, Div Canc Epidemiol & Genet, NIH, 9609 Med Ctr Dr Ste 7E528, Rockville, MD 20850 USA
[2] US EPA, Ctr Sci & Technol, Radiat Protect Div, Off Radiat & Indoor Air, Washington, DC USA
[3] Hirosoft Int, Eureka, CA USA
[4] Medpace Core Labs, Lyon, France
[5] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
[6] Univ Minnesota, Sch Publ Hlth, Div Environm Hlth Sci, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
(median; 0.70 mSv [IQR; 0.60-1.90 mSv; 95th percentile; 8.30); NUCLEAR-MEDICINE; SAFETY PRACTICES; CANCER-RISKS; PATTERNS; COHORT; HEALTH; STAFF; LENS;
D O I
10.1016/j.jvir.2024.03.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To summarize dose trends from 1980 to 2020 for 19,651 U.S. Radiologic Technologists who reported assisting with fluoroscopically guided interventional procedures (FGIPs), overall and by work history characteristics. Materials and Methods: A total of 762,310 annual personal dose equivalents at a 10-mm reference depth (doses) during 1980-2020 for 43,823 participants of the U.S. Radiologic Technologists (USRT) cohort who responded to work history questionnaires administered during 2012-2014 were summarized. This population included 19,651 technologists who reported assisting with FGIP (>= 1 time per month for >= 12 consecutive months) at any time during the study period. Doses corresponding to assistance with FGIP were estimated in terms of proximity to patients, monthly procedure frequency, and procedure type. Box plots and summary statistics (eg, medians and percentiles) were used to describe annual doses and dose trends. Results: Median annual dose corresponding to assistance with FGIP was 0.65 mSv (interquartile range [IQR], 0.60- 1.40 mSv; 95th percentile, 6.80). Higher occupational doses with wider variability were associated with close proximity to patients during assistance with FGIP (median, 1.20 mSv [IQR, 0.60-4.18 mSv]; 95th percentile, 12.66), performing >= 20 FGIPs per month (median, 0.75 mSv [IQR, 0.60-2.40 mSv]; 95th percentile, 9.44), and assisting with high-dose FGIP Conclusions: Occupational doses corresponding to assistance with FGIP were generally low but varied with exposure frequency, procedure type, and proximity to patients. These results highlight the need for vigilant dose monitoring, radiation safety training, and proper protective equipment.
引用
收藏
页码:1057 / 1065.e4
页数:13
相关论文
共 36 条
  • [1] [Anonymous], 2010, RES REPORT SERIES CO, P1
  • [2] [Anonymous], 2018, First generation ethanol blended petrol (EBP) Program, P1
  • [3] [Anonymous], 1993, Report 51
  • [4] [Anonymous], 2007, ANN ICRP, V37, P1
  • [5] RADIATION EXPOSURE TO OPERATOR PERFORMING CARDIAC ANGIOGRAPHY WITH U-ARM SYSTEMS
    BALTER, S
    SONES, FM
    BRANCATO, R
    [J]. CIRCULATION, 1978, 58 (05) : 925 - 932
  • [6] Interventional Radiology: A Half Century of Innovation
    Baum, Richard A.
    Baum, Stanley
    [J]. RADIOLOGY, 2014, 273 (2S) : S75 - S91
  • [7] OCCUPATIONAL EYE LENS DOSE OVER SIX YEARS IN THE STAFF OF A US HIGH-VOLUME CANCER CENTER
    Bellamy, M. B.
    Miodownik, D.
    Quinn, B.
    Dauer, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 321 - 327
  • [8] BOICE JD, 1992, CANCER, V69, P586, DOI 10.1002/1097-0142(19920115)69:2<586::AID-CNCR2820690251>3.0.CO
  • [9] 2-3
  • [10] Evolution of radiation protection for medical workers
    Boice, John, Jr.
    Dauer, Lawrence T.
    Kase, Kenneth R.
    Mettler, Fred A., Jr.
    Vetter, Richard J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1112)