Evaluation of Lift-Off Effect on Metal Testing with Non-Conductive Coating by Using Eddy Current Testing Technique

被引:0
|
作者
Harun, Syafiqa Putri Adlina [1 ]
Sulaiman, Fauziah [1 ]
机构
[1] Univ Malaysia Sabah, Fac Sci & Nat Resources, Ind Phys Program, Jalan UMS, Kota Kinabalu 88400, Sabah, Malaysia
来源
JURNAL FIZIK MALAYSIA | 2024年 / 45卷 / 01期
关键词
Eddy current testing; defect detection; lift-off; non-conductive coated; aluminium; 6061; stainless steel 304; CONDUCTIVITY; THICKNESS; OPTIMIZATION; INSPECTION; CRACKS;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study aims to develop an Eddy current testing (ECT) probe that generates Eddy current signals when a coil is placed above each magnetic (stainless steel 304) and non-magnetic (aluminium 6061) metal testing, with nonconductive coating and the presence of lift-off height, i.e., 0, 2.5, 5.0, 7.5, and 10.0 +/- 0.5 mm. Then this test is conducted with varying thicknesses, i.e., 1.5, 3.0, and 5.0 +/- 0.5 mm, and an artificial defect, i.e., 10, 20, and 30 +/- 0.5 mm, engraved on the metal testing. The coil probe is a rod-shaped solenoid coil designed with an iron core with 65 mm length, 5 mm2 area, and 200 N turns. It demonstrates how the rod-shaped solenoid coil may be used to detect various surface defects in aluminium 6061 (Al 6061) and stainless steel 304 (SS304). The optimal frequencies for Al6061 were 7.838 MHz, and SS304 metal was 7.956 MHz. In conclusion, the output voltage signals for each coated metal testing decreases as the lift-off height increases with increasing the thickness of metal. Therefore, as compared the magnetic and non-magnetic materials it shows the differences in the output voltage. Hence, the ECT technique in this study can detect surface defects appropriately for magnetic and non-magnetic materials.
引用
收藏
页码:10028 / 10038
页数:11
相关论文
共 50 条
  • [11] Analysis of the Lift-Off Effect in Motion-Induced Eddy Current Testing Based on Semi-Analytical Model
    Feng, Bo
    Xie, Shuangnan
    Xie, Lian
    Deng, Kangxuan
    Wang, Shenghan
    Kang, Yihua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 8
  • [12] Lift-off effect in high-frequency eddy current conductivity spectroscopy
    Abu-Nabah, Bassam A.
    Nagy, Peter B.
    NDT & E INTERNATIONAL, 2007, 40 (08) : 555 - 565
  • [13] Lift-Off Effect of Koch and Circular Differential Pickup Eddy Current Probes
    Chen, Guolong
    Cao, Zheng
    Zhang, Shuaishuai
    Wei, Ji
    Gao, Wei
    Jin, Wuyin
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2024, 37 (01)
  • [14] A Novel Conductivity Classification Technique for Nonmagnetic Metal Immune to Tilt Variations Using Eddy Current Testing
    Liu, Yushan
    Zhang, Zhijie
    Yin, Wuliang
    Chen, Haoze
    Yu, Zhenghui
    Wang, Quan
    IEEE ACCESS, 2021, 9 : 135334 - 135342
  • [15] SVM Classification of Thickness and Lift-off Using Transient Eddy Current Oscillation Method
    Angani, Chandra S.
    Ramos, Helena G.
    Rocha, Tiago J.
    Ribeiro, Artur L.
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 579 - 584
  • [16] Simultaneous Detection of Defect and Lift-off Using a Modified Pulsed Eddy Current Probe
    Sreevatsan, S.
    George, Boby
    IEEE SENSORS JOURNAL, 2020, 20 (04) : 2156 - 2163
  • [17] Reduction of lift-off effect in high-frequency apparent eddy current conductivity spectroscopy
    Abu-Nabah, Bassam A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [18] A Novel Compensation Algorithm for Thickness Measurement Immune to Lift-Off Variations Using Eddy Current Method
    Lu, Mingyang
    Yin, Liyuan
    Peyton, Anthony J.
    Yin, Wuliang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (12) : 2773 - 2779
  • [19] Numerical evaluation of the depth of branched-off cracks using eddy current testing signals
    Cheng, Weiying
    Kanemoto, Shigeru
    Komura, Ichiro
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (06) : 1030 - 1033