Clot in the Blood Bag: A Case Report

被引:0
作者
Rajkumar, Arthi [1 ]
Vetriveeran, Soundharya [1 ]
Iyyapan, Suresh Kumar [1 ]
Annadurai, Hari Haran [1 ]
James, Sahayaraj [1 ]
机构
[1] Saveetha Inst Med & Tech Sci, Saveetha Med Coll & Hosp, Transfus Med, Chennai, India
关键词
capa; fish bone diagram; root cause analysis; blood bag; blood clot;
D O I
10.7759/cureus.69452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Clot formation within a blood bag is a rare but significant issue, posing risks to the safety and quality of transfused blood products. We report the root cause analysis of a large clot found in a blood bag during routine component preparation. The analysis identified three potential contributing factors: improper vein selection leading to low flow rates, delays in tube stripping, and the use of a faulty blood collection monitor. These factors together facilitated the activation of coagulation, resulting in clot formation. To address these issues, corrective actions were implemented, including enhanced staff training on vein selection and phlebotomy techniques, timely and proper tube stripping procedures, and the replacement of faulty blood collection monitors with regularly calibrated equipment. Additionally, standard operating procedures (SOPs) were updated to incorporate these corrective measures. The implementation of these actions aims to prevent the recurrence of such incidents, ensuring the integrity of blood products and the safety of transfusion practices. This case highlights the importance of continuous monitoring and adherence to established protocols in blood collection and processing.
引用
收藏
页数:5
相关论文
共 8 条
[1]  
Acker J, 2023, Technical Manual, P141
[2]  
Dara Ravi C, 2015, Asian J Transfus Sci, V9, P217, DOI 10.4103/0973-6247.162732
[3]   Automated blood-mixing devices still fail to mix at low bleeding rates [J].
de Korte, D ;
Veldman, HA .
VOX SANGUINIS, 2001, 80 (01) :34-39
[4]  
Harmening D, 2019, Modern Blood Banking and Transfusion Practices, P1
[5]  
Hoque A, 2019, J Med Sci Clin Res, V7, P327, DOI [10.18535/jmscr/v7i6.56, DOI 10.18535/JMSCR/V7I6.56]
[6]   Ichthyosis in blood donors [J].
Maheshwari, Ashish ;
Gupta, Somesh ;
Bajpai, Meenu .
TRANSFUSION, 2022, 62 (02) :265-266
[7]   Zeroing in on the root cause of the clots in a blood bag: Reinforcing improvement in blood collection practices [J].
Raturi, Manish ;
Kediya, Ayushi ;
Kala, Mansi ;
Sahrawat, Adityaveer .
TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2021, 28 (03) :303-305
[8]  
Shastry Shamee, 2016, Asian J Transfus Sci, V10, P3, DOI 10.4103/0973-6247.175385