Accuracy of deep learning in the differential diagnosis of coronary artery stenosis: a systematic review and meta-analysis

被引:0
|
作者
Tu, Li [1 ]
Deng, Ying [1 ]
Chen, Yun [1 ]
Luo, Yi [1 ]
机构
[1] Chongqing Med Univ, Dept Cardiovasc Dis, Branch 1, Affiliated Hosp 1, 191 Renmin Rd, Chongqing 400012, Peoples R China
来源
BMC MEDICAL IMAGING | 2024年 / 24卷 / 01期
关键词
Artificial intelligence; Deep learning; Coronary artery stenosis; FRACTIONAL FLOW RESERVE; ARTIFICIAL-INTELLIGENCE; ANGIOGRAPHY; PERFORMANCE; DISEASE;
D O I
10.1186/s12880-024-01403-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In recent years, as deep learning has received widespread attention in the field of heart disease, some studies have explored the potential of deep learning based on coronary angiography (CAG) or coronary CT angiography (CCTA) images in detecting the extent of coronary artery stenosis. However, there is still a lack of a systematic understanding of its diagnostic accuracy, impeding the advancement of intelligent diagnosis of coronary artery stenosis. Therefore, we conducted this study to review the accuracy of image-based deep learning in detecting coronary artery stenosis. Methods We retrieved PubMed, Cochrane, Embase, and Web of Science until April 11, 2023. The risk of bias in the included studies was appraised using the QUADAS-2 tool. We extracted the accuracy of deep learning in the test set and performed subgroup analyses by binary and multiclass classification scenarios. We performed a subgroup analysis based on different degrees of stenosis and applied a double arcsine transformation to process the data. The analysis was done by using R. Results Our systematic review finally included 18 studies, involving 3568 patients and 13,362 images. In the included studies, deep learning models were constructed based on CAG and CCTA. In binary classification tasks, the accuracy for detecting > 25%, > 50% and > 70% degrees of stenosis at the vessel level were 0.81 (95% CI: 0.71-0.85), 0.73 (95% CI: 0.58-0.88) and 0.61 (95% CI: 0.56-0.65), respectively. In multiclass classification tasks, the accuracy for detecting 0-25%, 25-50%, 50-70%, and 70-100% degrees of stenosis at the vessel level were 0.78 (95% CI: 0.73-0.84), 0.86 (95% CI: 0.78-0.93), 0.83 (95% CI: 0.70-0.97), and 0.70 (95% CI: 0.42-0.98), respectively. Conclusions Our study shows that deep learning models based on CAG and CCTA appear to be relatively accurate in diagnosing different degrees of coronary artery stenosis. However, for various degrees of stenosis, their accuracy still needs to be further improved.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Deep learning algorithms for melanoma detection using dermoscopic images: A systematic review and meta-analysis☆
    Ye, Zichen
    Zhang, Daqian
    Zhao, Yuankai
    Chen, Mingyang
    Wang, Huike
    Seery, Samuel
    Qu, Yimin
    Xue, Peng
    Jiang, Yu
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2024, 155
  • [22] Deep Learning in Glaucoma Detection and Progression Prediction: A Systematic Review and Meta-Analysis
    Ling, Xiao Chun
    Chen, Henry Shen-Lih
    Yeh, Po-Han
    Cheng, Yu-Chun
    Huang, Chu-Yen
    Shen, Su-Chin
    Lee, Yung-Sung
    BIOMEDICINES, 2025, 13 (02)
  • [23] Performance of deep learning in the detection of intracranial aneurysm: systematic review and meta-analysis
    Gu, Feng
    Wu, Xiaoxiao
    Wu, Wenxue
    Wang, Zilan
    Yang, Xingyu
    Chen, Zhouqing
    Wang, Zhong
    Chen, Gang
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [24] Deep Learning for Detecting Brain Metastases on MRI: A Systematic Review and Meta-Analysis
    Ozkara, Burak B. B.
    Chen, Melissa M. M.
    Federau, Christian
    Karabacak, Mert
    Briere, Tina M. M.
    Li, Jing
    Wintermark, Max
    CANCERS, 2023, 15 (02)
  • [25] Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis
    Panjer, Mariska
    Dobrolinska, Magdalena
    Wagenaar, Nils R. L.
    Slart, Riemer H. J. A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (04) : 1686 - 1697
  • [26] Vasodilator Myocardial Perfusion Cardiac Magnetic Resonance Imaging Is Superior to Dobutamine Stress Echocardiography in the Detection of Relevant Coronary Artery Stenosis: A Systematic Review and Meta-Analysis on Their Diagnostic Accuracy
    Haberkorn, Sebastian M.
    Haberkorn, Sandra I.
    Bonner, Florian
    Kelm, Malte
    Hopkin, Gareth
    Petersen, Steffen E.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [27] Accuracy of pulse wave velocity for screening coronary artery disease: a systematic review and meta-analysis
    Lever-Megina, Carla-Geovanna
    Cavero-Redondo, Ivan
    alvarez-Bueno, Celia
    Morales-Berenkova, Cristina
    Cabeza-Arrebola, German
    Saz-Lara, Alicia
    DIAGNOSIS, 2025,
  • [28] Diagnosis accuracy of machine learning for idiopathic pulmonary fibrosis: a systematic review and meta-analysis
    Li Cong
    Ying Chen
    Xiaolei He
    MaiLiKai KuErBan
    Chao Wu
    Liping Chen
    European Journal of Medical Research, 30 (1)
  • [29] Transradial Versus Transfemoral Access for Percutaneous Coronary Intervention of Unprotected Left Main Coronary Artery Stenosis: A Systematic Review and Meta-Analysis
    Bajaj, Anurag
    Pancholy, Samir
    Sothwal, Arpit
    Nawaz, Yassir
    Boruah, Pranjal
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (09) : 790 - 798
  • [30] Deep learning for age estimation from panoramic radiographs: A systematic review and meta-analysis
    Rokhshad, Rata
    Nasiri, Fateme
    Saberi, Naghme
    Shoorgashti, Reyhane
    Ehsani, Sarah Sadat
    Nasiri, Zahra
    Azadi, Ali
    Schwendicke, Falk
    JOURNAL OF DENTISTRY, 2025, 154