Relationship between OSA pathophysiological phenotypes and treatment response to mandibular advancement devices: a pilot study

被引:0
|
作者
Manetta, Izabella P. [1 ,2 ]
Duarte, Bruno B. [2 ]
Nucci, Luciana B. [1 ]
Enes, Carla C. [1 ]
机构
[1] Pontificia Univ Catolica Campinas, Postgrad Program Hlth Sci, Campinas, SP, Brazil
[2] Pontificia Univ Catolica Campinas, Dept Otolaryngol Head & Neck Surg, Av John Boyd Dunlop,S-N Jardim Londres, BR-13034685 Campinas, SP, Brazil
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2024年 / 20卷 / 08期
关键词
sleep apnea; phenotype; mandibular advancement device; polysomnography; OBSTRUCTIVE SLEEP-APNEA; ORAL APPLIANCE TREATMENT; ELECTROMYOGRAPHIC ACTIVITY; PREDICTORS; POPULATION; EFFICACY; THERAPY; SPLINT;
D O I
10.5664/jcsm.11138
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: We assessed whether critical pathophysiological phenotypes predict treatment response in patients with obstructive sleep apnea using a mandibular advancement device (MAD). Methods: Thirty-one patients with obstructive sleep apnea were treated with a MAD. Individuals were categorized and graded into 4 pathophysiological phenotypes based on polysomnographic features (anatomical, ventilatory control, arousal threshold, and muscle responsiveness). Morpho-anthropometric data were additionally assessed. Patients were classified as responders or nonresponders. Associations between polysomnographic phenotypes and treatment response were documented, as were morpho-anthropometric data and their impact on therapeutic success. Results: There was a male predominance (64.5%), with a median age of 49 years (25th percentile: 40; 75th percentile: 55), body mass index = 27.4 kg/m(2) (25th percentile: 26; 75th percentile: 28.8), and apnea-hypopnea index of 18.2 events/h (25th percentile: 11.7; 75th percentile: 27.6). The majority of patients treated with a MAD (58%) were good responders (68.0% mild and moderate vs 16.7% severe). Treatment response was associated with shorter intermolar and interpremolar distances in the lower arch (P = .0092 and .0129). Rapid eye movement sleep apnea-hypopnea index and MAD-related treatment response were inversely correlated (P = .0013). Favorable anatomical (P = .0339) and low muscle response (P = .0447) phenotypes were correlated with outcomes. Conclusions: According to our results, a favorable response occurred in a better "anatomical phenotype" and in the worse "muscular responsiveness phenotype" according to polysomnographic data. Furthermore, other favorable predictors, such as a rapid eye movement sleep apnea-hypopnea index < 16 events/h and a smaller distance between lower molars and premolars, were found. These findings indicate that clinical and polysomnographic aspects can discriminate phenotypes that may guide decisions on MAD treatment for obstructive sleep apnea.
引用
收藏
页码:1321 / 1330
页数:10
相关论文
共 50 条
  • [21] Predictive factors of therapeutic response according to craniofacial skeletal biotype in patients with sleep apnea syndrome using mandibular advancement devices: a pilot study
    Navarro, Rafael Ecija
    Karadede, Bersan
    Unal, Beyza Karadede
    Salvador, Domingo Martin
    ANGLE ORTHODONTIST, 2024, 94 (02) : 216 - 223
  • [22] Self-reported improvement in obstructive sleep apnea symptoms compared to treatment response with mandibular advancement device therapy: a retrospective study
    Sangalli, Linda
    Yanez-Regonesi, Fernanda
    Fernandez-Vial, Diego
    Moreno-Hay, Isabel
    SLEEP AND BREATHING, 2023, 27 (04) : 1577 - 1588
  • [23] Preliminary simulation model toward the study of the effects caused by different mandibular advancement devices in OSAS treatment
    Brunzini, Agnese
    Gracco, Antonio
    Mazzoli, Alida
    Mandolini, Marco
    Manieri, Steve
    Germani, Michele
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (13) : 693 - 702
  • [24] Can treatment with statins have a negative influence on the tolerance of mandibular advancement devices?
    Gonzalez, Monica
    Macias-Escalada, Emilio
    Cobo, Juan
    Fernandez Mondragon, Maria Pilar
    Gomez-Moreno, Gerardo
    Martinez-Martinez, Marian
    de Carlos, Felix
    SLEEP AND BREATHING, 2016, 20 (04) : 1363 - 1366
  • [25] Use of mandibular advancement devices for the treatment of primary snoring with or without obstructive sleep apnea (OSA): A systematic review
    De Meyer, Micheline M. D.
    Vanderveken, Olivier M.
    De Weerdt, Sonia
    Marks, Luc A. M.
    Carcamo, Bernadita A.
    Chavez, Andres M.
    Matamoros, Felipe A.
    Jacquet, Wolfgang
    SLEEP MEDICINE REVIEWS, 2021, 56
  • [26] The treatment of mild OSA with CPAP or mandibular advancement device and the effect on blood pressure and endothelial function after one year of treatment
    Guimaraes, Thais Moura
    Poyares, Dalva
    e Silva, Luciana Oliveira
    Luz, Gabriela
    Coelho, Glaury
    Dal Fabbro, Cibele
    Tufik, Sergio
    Bittencourt, Lia
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (02): : 149 - 158
  • [27] Cephalometric predictors of treatment outcome with mandibular advancement devices in adult patients with obstructive sleep apnea: a systematic review
    Alessandri-Bonetti, Giulio
    Ippolito, Daniela Rita
    Bartolucci, Maria Lavinia
    D'Anto, Vincenzo
    Incerti-Parenti, Serena
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (06) : 308 - 321
  • [28] Current Perspectives in Treatment of Obstructive Sleep Apnea with Mandibular Advancement Devices: A Narrative Review
    Gunel, Elvin
    Kurtulmus, Huseyin
    Bursa, Muhammet Caglar
    Peker, Yuksel
    CURRENT PULMONOLOGY REPORTS, 2025, 14 (01)
  • [29] Mandibular advancement devices in the treatment of obstructive sleep apnea. A necessary and effective option
    Sampol Rubio, Gabriel
    Macias Escalada, Emilio
    Montserrat Canal, Josep Maria
    Teran Santos, Joaquin
    MEDICINA CLINICA, 2018, 151 (01): : 34 - 38
  • [30] Forces created by mandibular advancement devices in OSAS patientsA pilot study during sleep
    J. Cohen-Levy
    B. Pételle
    J. Pinguet
    E. Limerat
    B. Fleury
    Sleep and Breathing, 2013, 17 : 781 - 789