The Effect of Increasing Thread Depth on the Initial Stability of Dental Implants: An In Vitro Study

被引:1
|
作者
Cucinelli, Chiara [1 ]
Pereira, Miguel Silva [1 ,2 ]
Borges, Tiago [1 ,2 ]
Figueiredo, Rui [3 ,4 ]
Leitao-Almeida, Bruno [1 ,2 ]
机构
[1] Univ Catolica Portuguesa, Fac Dent, P-3510 Viseu, Portugal
[2] Univ Catolica Portuguesa, Ctr Interdisciplinary Res Hlth CIIS, P-3510 Viseu, Portugal
[3] Univ Barcelona, Fac Med & Hlth Sci, Barcelona 08907, Spain
[4] Inst Invest Biomed Bellvitge IDIBELL, Barcelona 08908, Spain
来源
SURGERIES | 2024年 / 5卷 / 03期
关键词
dental implants; osseointegration; torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; BONE-DENSITY; GEOMETRY; QUALITY;
D O I
10.3390/surgeries5030065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The long-term success of dental implants largely depends on achieving primary stability, previously described as crucial to obtaining osseointegration and immediate loading protocol requirements. Implant thread depths seem to be one of the key factors influencing primary stability, particularly in low-density bone. Insertion torque (IT) and resonance frequency analysis (RFA) are considered the most reliable tests to assess primary stability. The aim of this work was to evaluate how different thread depths of commercially available dental implants affect primary stability in low-density D3 bone. Materials and Methods: An in vitro study was carried out between February 2024 and March 2024. Twenty-four dental implants were divided into four groups (six implants each) according to their thread depths (Group A: 4 mm, Group B: 4.5 mm, Group C: 5 mm, Group D: 5.5 mm) and were inserted in D3-type artificial bone blocks. The main outcome variables were the IT and the Implant Stability Quotient (ISQ) measured in four different areas of the implant (buccal, lingual, mesial, and distal) with an Osstel (R) ISQ reader. Descriptive and inferential analyses of the data were performed, and the significance value was set at 5%. Results: A total of 24 implants were analyzed. The highest IT values were obtained in Group D, with a mean of 54.03 Ncm (standard deviation (SD) = 8.99), while the lowest measurements were observed in Group A (mean = 25.12; SD: 2.96 N.cm). The mean ISQ values were consistently higher in Group D for each analyzed area, with a mean of 70.13 N.cm (SD = 1.12). Conclusions: Taking into consideration the limitations of this in vitro study, greater thread depths seem to increase the primary stability of dental implants placed in soft bone. Furthermore, a positive correlation was observed between all IT and ISQ values, regardless of the thread depth.
引用
收藏
页码:817 / 825
页数:9
相关论文
共 50 条
  • [21] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333
  • [22] Effect of bone density on the damping behavior of dental implants: An in vitro method
    VanSchoiack, Lindsey R.
    Wu, Jean C.
    Sheets, Cherilyn G.
    Earthman, James C.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (08): : 1307 - 1311
  • [23] Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region
    Homma, Shinya
    Makabe, Yasushi
    Sakai, Takuya
    Morinaga, Kenzou
    Yokoue, Satoru
    Kido, Hirofumi
    Yajima, Yasutomo
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [24] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [25] Insertion Speed Affects the Initial Stability of Dental Implants
    Hsu, Yuan-Yang
    Tsai, Ming-Tzu
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Hsu, Jui-Ting
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 516 - 525
  • [26] The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study
    Pagliani, L.
    Sennerby, L.
    Petersson, A.
    Verrocchi, D.
    Volpe, S.
    Andersson, P.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (03) : 221 - 227
  • [27] Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study
    Tozum, T. F.
    Bal, B. T.
    Turkyilmaz, I.
    Gulay, G.
    Tulunoglu, I.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (03) : 217 - 224
  • [28] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [29] In-vitro evaluation of the primary stability of multiple condensing thread designed implants placed by novice and experienced clinicians
    Javed, Fawad
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Romanos, Georgios E.
    SURGERY IN PRACTICE AND SCIENCE, 2020, 2
  • [30] Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study
    Barbera-Millan, Javier
    Larrazabal-Moron, Carolina
    Jose Eneiso-Ripoll, Juan
    Perez-Pevida, Esteban
    Chavarri-Prado, David
    Dolores Gomez-Adrian, Maria
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (03): : E361 - E367