Redundant Induced Bracing Failures in Transmission Line Towers

被引:1
|
作者
Rao, N. Prasad [1 ]
Balagopal, R. [1 ]
Rokade, R. P. [1 ]
Palani, G. S. [1 ]
机构
[1] CSIR Struct Engn Res Ctr, CSIR Rd, Chennai 600113, Tamil Nadu, India
关键词
Transmission line tower; Redundant; Primary bracing; Failure; Connection detail; Tower testing; BEHAVIOR;
D O I
10.1007/s13296-024-00897-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Transmission line towers designed based on the provisions of different standards may fail during mandatory testing for many reasons. Two different types of premature failures observed during full-scale testing at Tower Testing and Research Station, Structural Engineering Research Centre, Chennai (CSIR-SERC), are studied in this paper. These towers failed prematurely due to improper design assumptions secondary to the primary bracing connection. The failures are modelled using general-purpose finite element software. The test and analytical results are compared with various codal provisions. Hip bracing connected to primary bracing with a single bolt acts as a hinge and fails to provide adequate restraint. The assumption that hip bracing provides restraint to the primary bracing against the in-plane deformation is invalid, and it can only prevent the primary member's displacement along the hip's axis due to its axial stiffness. This study recommends a double bolt connection for redundant members.
引用
收藏
页码:1154 / 1164
页数:11
相关论文
共 50 条
  • [41] Assessment of the backflashover occurrence rate on HV transmission line towers
    Sarajcev, Petar
    Goic, Ranko
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2012, 22 (02): : 152 - 169
  • [42] Online monitoring system of the grounding status of transmission line towers
    Li, Wei
    Lu, Hailiang
    He, Zhiqiang
    Zhu, Changcheng
    Quan, Jiangtao
    Wen, Xishan
    Lecture Notes in Electrical Engineering, 2015, 334 : 449 - 457
  • [43] RELIABILITY-BASED OPTIMIZATION OF TRANSMISSION-LINE TOWERS
    NATARAJAN, K
    SANTHAKUMAR, AR
    COMPUTERS & STRUCTURES, 1995, 55 (03) : 387 - 403
  • [44] RELIABILITY ASSESSMENT OF OVERHEAD TRANSMISSION LINE TOWERS IN THE REPUBLIC OF CROATIA
    Komorski, Ana
    Skejic, Davor
    Dujmovic, Darko
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2013, 20 (03): : 381 - 390
  • [45] Joint stress based deflection limits for transmission line towers
    Gayathri, B.
    Ramalingam, Raghavan
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (01): : 45 - 53
  • [46] Behaviour of cold formed lipped angles in transmission line towers
    Mohan, S. J.
    Shabeen, S. Rahima
    Knight, G. M. Samuel
    THIN-WALLED STRUCTURES, 2006, 44 (09) : 1017 - 1030
  • [48] Software based on heuristic technique for optimization of transmission line towers
    Structural Engineering Research Centre, CSIR Campus, Taramani, Chennai - 600 113, India
    不详
    J Struct Eng, 2006, 2 (157-166):
  • [49] Reliability assessment of overhead transmission line towers in the Republic of Croatia
    Procjena pouzdanosti dalekovodnih stupova u Republici Hrvatskoj
    2013, Strojarski Facultet (20):
  • [50] Optimum designs for transmission line towers based on failure modes
    Zheng, Min
    Xiong, Tiehua
    Liang, Shuguo
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2014, 45 (05): : 1672 - 1679