On the Role and Evolution of Local Grain Size Heterogeneity During Confined Compression of Boise Sandstone as Seen by X-ray Micro-CT Imaging

被引:0
|
作者
Louis, Laurent [1 ]
Boyd, Peter [2 ]
Hofmann, Ronny [3 ]
Saxena, Nishank [3 ]
机构
[1] Houston Res Ctr, Aramco Amer, 16300 Pk Row, Houston, TX 77084 USA
[2] New England Res Inc, 331 Olcott Dr,Ste L1, White River Jct, VT 05001 USA
[3] Shell Int Explorat & Prod, 3333 S Texas 6, Houston, TX 77082 USA
关键词
X-ray CT imaging; Mechanical compaction; Image segmentation; Grain size distribution; STRAIN LOCALIZATION; COMPACTION BANDS; ACOUSTIC-EMISSION; POROUS SANDSTONES; CATACLASTIC FLOW; ROCK; MICROMECHANICS; DEFORMATION; PRESSURE; MICROTOMOGRAPHY;
D O I
10.1007/s00603-024-04152-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
MicroCT imaging is performed before and after confined compression testing of a minicore of Boise sandstone to extract quantitative information on the microstructural controls on compaction initiation and distribution, and to test whether grain size distributions tend to conform to a power law through comminution. In contrast with traditional compaction studies, this analysis focuses on local statistics among regions of a given sample as opposed to global statistics in a sample set. The original workflow includes a segmentation strategy and the definition of a series of metrics that are evaluated throughout the entire image volumes before and after testing. The results suggest that local porosity and sorting are the main controls on local strength, whereas neighborhoods with larger mean grain size do not appear to be more prone to yielding. Furthermore, our observations appear to confirm the tendency of grain size distributions to become self-similar through the elimination of same size neighbors at all scales, consistent with the concept of fractal compression. The relationship between grain size statistics and the compaction process is studied by contrasting image-derived metrics among many sub-regions of a sandstone CT scan.Despite a large influence of the macroscopic stress distribution associated with the testing conditions, local metrics statistically provide meaningful insight.Porosity and sorting emerge as the main controls on local strength, whereas neighborhoods with larger mean grain size are not more prone to yielding.Upon grain microcracking and crushing, grain size distributions conform to power laws, consistent with geological observations and numerical simulations.This work provides a possible path to image-based prediction of compaction initiation and development in high porosity aggregates.
引用
收藏
页数:22
相关论文
共 15 条
  • [1] Fracture evolution mechanism of hollow sandstone under conventional triaxial compression by X-ray micro-CT observations and three-dimensional numerical simulations
    Yang, Sheng-Qi
    Yang, Zhen
    Jing, Hong-Wen
    Xu, Tao
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2020, 190 : 156 - 180
  • [2] Imaging of metallic foams using X-ray micro-CT
    Saadatfar, M.
    Garcia-Moreno, F.
    Hutzler, S.
    Sheppard, A. P.
    Knackstedt, M. A.
    Banhart, J.
    Weaire, D.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 344 (1-3) : 107 - 112
  • [3] Fracturing Mechanism of Compressed Hollow-Cylinder Sandstone Evaluated by X-ray Micro-CT Scanning
    Yang, Sheng-Qi
    ROCK MECHANICS AND ROCK ENGINEERING, 2018, 51 (07) : 2033 - 2053
  • [4] Probing the Pore Structure of the Berea Sandstone by Using X-ray Micro-CT in Combination with ImageJ Software
    Hu, Zhazha
    Zhang, Rui
    Zhu, Kai
    Li, Dongyin
    Jin, Yi
    Guo, Wenbing
    Liu, Xiao
    Zhang, Xiaodong
    Zhang, Qian
    MINERALS, 2023, 13 (03)
  • [5] Techniques in helical scanning, dynamic imaging and image segmentation for improved quantitative analysis with X-ray micro-CT
    Sheppard, Adrian
    Latham, Shane
    Middleton, Jill
    Kingston, Andrew
    Myers, Glenn
    Varslot, Trond
    Fogden, Andrew
    Sawkins, Tim
    Cruikshank, Ron
    Saadatfar, Mohammad
    Francois, Nicolas
    Arns, Christoph
    Senden, Tim
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 324 : 49 - 56
  • [6] Environmental cell for in situ X-ray synchrotron micro-CT imaging with simultaneous acoustic measurements
    Drobchik, Arkady N.
    Nikitin, Viktor V.
    Fokin, Mikhail, I
    Dugarov, Geser A.
    Shevchenko, Pavel D.
    Deriy, Alex L.
    Manakov, Andrey Yu
    Kuper, Konstantin E.
    Duchkov, Anton A.
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 515 - 521
  • [7] X-ray micro-CT scanner for small animal imaging based on Timepix detector technology
    Dudak, Jan
    Zemlicka, Jan
    Krejci, Frantisek
    Polansky, Stepan
    Jakubek, Jan
    Mrzilkova, Jana
    Patzelt, Matej
    Trnka, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 773 : 81 - 86
  • [8] In-situ X-ray micro-CT quantitative analysis and modelling the damage evolution in granite rock
    Hu, Qinxin
    Yang, Shangtong
    Xi, Xun
    Shipton, Zoe K.
    Minto, James
    Hu, Xiaofei
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2024, 133
  • [9] Experimental Study of Mechanical Behavior and X-Ray Micro CT Observations of Sandstone Under Conventional Triaxial Compression
    Yang, Sheng-Qi
    Ranjith, P. G.
    Gui, Yi-Lin
    GEOTECHNICAL TESTING JOURNAL, 2015, 38 (02): : 179 - 197
  • [10] Three dimensional imaging of porosity and tracer concentration distributions in a dolostone sample during diffusion experiments using X-ray micro-CT
    Agbogun, H. M. D.
    Al, Tom A.
    Hussein, Esam M. A.
    JOURNAL OF CONTAMINANT HYDROLOGY, 2013, 145 : 44 - 53