Experimental study on concrete-filled L-shaped steel tubular columns and beam-columns

被引:0
|
作者
Lei, Min [1 ]
Li, Ying-Lei [2 ]
Li, Yuan-Qi [3 ]
Zhang, Jicheng [4 ]
Lin, Zhenyu [3 ]
Zhou, Tong [5 ]
Luan, Wei [6 ]
机构
[1] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[3] Tongji Univ, Dept Bldg Engn, Shanghai 200092, Peoples R China
[4] Yangtze Univ, Sch Urban Construct, Jingzhou 434023, Peoples R China
[5] China MCC5 Grp Co Ltd, Chengdu 610031, Sichuan, Peoples R China
[6] China Construct Eighth Engn Div Co Ltd, Shanghai 200135, Peoples R China
来源
关键词
Concrete-filled L-shaped steel tube; Axial and eccentric compression; Buckling behavior; Ultimate capacity; Interaction relationship; REINFORCED-CONCRETE; BEHAVIOR; TESTS; TUBES;
D O I
10.1016/j.jobe.2024.110626
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled L-shaped steel tube (CFLST) is an efficient structural form for corner columns in high-rise buildings, which avoids column protrusion. This paper presents an experimental and theoretical study on the structural behavior of CFLST columns and beam-columns. A total of nine full-scale specimens (i.e., three stub columns, two slender columns, and four slender beamcolumns) was tested under compressive loads and the specimen ends were free to rotate about a geometric axis. Plastic local buckling was observed for the stub columns and the confinement effect was not obvious. Flexural buckling occurred for the slender columns and beam-columns. With the increase in the applied load, the neutral axis shifted to the compressive side of the beam-column. Performance of current design codes, which apply for rectangular CFSTs, on predicting the ultimate capacities of CFLSTs was assessed. The prediction for section capacity was conservative and it was likely caused by the reduction in the design strength of concrete. The buckling curve in design codes for rectangular CFSTs was applicable for CFLST columns whereas the interaction relationship specified in design codes underestimates the ultimate capacities of CFLST beam-columns. Based on fiber element analysis, out-of-plane bending moment was found in the tested CFLST slender members and the values were quantified. A new interaction relationship was proposed for CFLST beam-columns, which exhibited good agreement with experimental and numerical results. Finally, design methods were recommended for CFLST columns and beam-columns.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Experimental investigation into axial compressive behavior of L-shaped concrete-filled steel tubular stub columns with binding bars
    Long, Yue-Ling
    Cai, Jian
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2006, 34 (11): : 87 - 92
  • [22] Experimental analysis on circular concrete-filled steel tubular beam-columns under unequal load eccentricities
    Albero, V
    Ibanez, C.
    Hernandez-Figueirido, D.
    Piquer, A.
    ENGINEERING STRUCTURES, 2022, 259
  • [23] Hysteretic behaviors of concrete-filled steel SHS beam-columns
    Tao, Z
    Han, LH
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 591 - 598
  • [24] Behavior of concrete-filled T-shaped steel tubular beam-columns under biaxial compressive loads
    Lei, Min
    Li, Ying-Lei
    Li, Yuan-Qi
    Zhang, Jicheng
    Liu, Dewen
    ENGINEERING STRUCTURES, 2023, 277
  • [25] An experimental behaviour of concrete-filled steel tubular columns
    Zeghiche, J
    Chaoui, K
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (01) : 53 - 66
  • [26] Design of L-shaped and T-shaped concrete-filled steel tubular stub columns under axial compression
    Zheng, Yongqian
    Zeng, Shaoxi
    ENGINEERING STRUCTURES, 2020, 207
  • [27] Simplified numerical modelling of rectangular concrete-filled steel columns, beams and beam-columns
    Tao, Z.
    Katwal, U.
    Hassan, M. K.
    Wang, W. D.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 19 - 27
  • [28] Research study on the structural performance of concrete filled steel tubular beam-columns
    Fujimoto, T
    Demizu, T
    Ueda, H
    Tanaka, H
    Nishiuchi, K
    Fukumoto, T
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 849 - 855
  • [29] Behaviour of concrete-filled double skin (CHS inner and CHS outer) steel tubular stub columns and beam-columns
    Tao, Z
    Han, LH
    Zhao, XL
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (08) : 1129 - 1158
  • [30] Dynamic behavior of CFRP-reinforced square concrete-filled steel tubular beam-columns
    Wang, Zhi-Bin, 1600, Editorial Department of Journal of Chang'an University (Natural Science Edition) (34):