Novel Quantitative Liver Steatosis Assessment Method With Ultrasound Harmonic Imaging

被引:0
作者
Gong, Ping [1 ]
Zhang, Jingke [1 ]
Huang, Chengwu [1 ]
Lok, U-Wai [1 ]
Tang, Shanshan [1 ]
Liu, Hui [1 ,2 ]
Deruiter, Ryan [1 ]
Peterson, Kendra [1 ]
Knoll, Kate [1 ]
Robinson, Kathryn [1 ]
Watt, Kymberly [3 ]
Callstrom, Matthew [1 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clinic, Dept Radiol, Rochester, MN 55905 USA
[2] Fujian Med Univ, Affiliated Hosp 1, Dept Ultrasound, Fuzhou, Peoples R China
[3] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN USA
关键词
quantitative evaluation of liver steatosis; ultrasound attenuation coefficient estimation; ultrasound harmonic imaging; HEPATIC STEATOSIS; DISEASE; DIAGNOSIS; AREAS;
D O I
10.1002/jum.16582
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Metabolic dysfunction-associated steatotic liver disease (MASLD) isthe most prevalent liver disorder in Western countries, with approximately 20%-30% of the MASLD patients progressing to severe stages. There is an urgentneed for noninvasive, cost-effective, widely accessible, and precise biomarkers toevaluate liver steatosis. This study aims to assess and compare the diagnostic per-formance of a novel reference frequency method-based ultrasound attenuationcoefficient estimation (ACE) in both fundamental (RFM-ACE-FI) and harmonic(RFM-ACE-HI) imaging for detecting and grading liver steatosis. Methods-An Institutional Review Board-approved prospective study was car-ried out between December 2018 and October 2022. A total number of 130 sub-jects were enrolled in the study. The correlation between RFM-ACE-HI valuesand magnetic resonance imaging proton density fat fraction (MRI-PDFF), aswell as between RFM-ACE-FI values and MRI-PDFF were calculated. The diag-nostic performance of RFM-ACE-FI and RFM-ACE-HI was evaluated usingreceiver operating characteristic (ROC) curve analysis, as compared to MRI-PDFF. The reproducibility of RFM-ACE-HI was assessed by interobserveragreement between two sonographers. Results-A strong correlation was observed between RFM-ACE-HI and MRI-PDFF, withR=0.88 (95% confidence interval [CI]: 0.83-0.92;P< .001),while the correlation between RFM-ACE-FI and MRI-PDFF wasR=0.65(95% CI: 0.50-0.76;P< .001). The area under the ROC (AUROC) curve forRFM-ACE-HI in staging liver steatosis grades of S >= 1 and S >= 2 was 0.97 (95%CI: 0.91-0.99;P< .001) and 0.98 (95% CI: 0.93-1.00;P< .001), respectively,and 0.76 (95% CI: 0.65-0.85) and 0.80 (95% CI: 0.70-0.88) for RFM-ACE-FI,respectively. Great reproducibility was achieved for RFM-ACE-HI, with an inter-observer agreement ofR=0.97 (95% CI: 0.94-0.99;P< .001). Conclusions-The novel RFM-ACE-HI method offered high liver steatosis diag-nostic accuracy and reproducibility, which has important clinical implications forearly disease intervention and treatment evaluation
引用
收藏
页码:77 / 85
页数:9
相关论文
共 27 条
[1]   Validity of real time ultrasound in the diagnosis of hepatic steatosis: A prospective study [J].
Dasarathy, Srinivasan ;
Dasarathy, Jaividhya ;
Khiyami, Amer ;
Joseph, Rajesh ;
Lopez, Rocio ;
McCullough, Arthur J. .
JOURNAL OF HEPATOLOGY, 2009, 51 (06) :1061-1067
[2]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[3]  
EASL, 2016, OBESITY FACTS, V9, P65, DOI [10.1159/000443344, 10.1016/j.jhep.2015.11.004, 10.1007/s00125-016-3902-y]
[4]   WFUMB Guidelines/Guidance on Liver Multiparametric Ultrasound. Part 2: Guidance on Liver Fat Quantification [J].
Ferraioli, Giovanna ;
Barr, Richard Gary ;
Berzigotti, Annalisa ;
Sporea, Ioan ;
Wong, Vincent Wai-Sun ;
Reiberger, Thomas ;
Karlas, Thomas ;
Thiele, Maja ;
Cardoso, Ana Carolina ;
Ayonrinde, Oyekoya Taiwo ;
Castera, Laurent ;
Dietrich, Christoph Frank ;
Iijima, Hiroko ;
Lee, Dong Ho ;
Kemp, William ;
Oliveira, Claudia P. ;
Sarin, Shiv Kumar .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (08) :1088-1098
[5]   US Attenuation for Liver Fat Quantification: An AIUM-RSNA QIBA Pulse-Echo Quantitative Ultrasound Initiative [J].
Ferraioli, Giovanna ;
Kumar, Viksit ;
Ozturk, Arinc ;
Nam, Kibo ;
de Korte, Chris L. ;
Barr, Richard G. .
RADIOLOGY, 2022, 302 (03) :495-506
[6]   QUANTIFICATION OF LIVER FAT CONTENT WITH ULTRASOUND: A WFUMB POSITION PAPER [J].
Ferraioli, Giovanna ;
Berzigotti, Annalisa ;
Barr, Richard G. ;
Choi, Byung I. ;
Cui, Xin Wu ;
Dong, Yi ;
Gilja, Odd Helge ;
Lee, Jae Young ;
Lee, Dong Ho ;
Moriyasu, Fuminori ;
Piscaglia, Fabio ;
Sugimoto, Katsutoshi ;
Wong, Grace Lai-Hung ;
Wong, Vincent Wai-Sun ;
Dietrich, Christoph F. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (10) :2803-2820
[7]   Detection of Liver Steatosis With a Novel Ultrasound- Based Technique: A Pilot Study Using MRI-Derived Proton Density Fat Fraction as the Gold Standard [J].
Ferraioli, Giovanna ;
Maiocchi, Laura ;
Raciti, Maria Vittoria ;
Tinelli, Carmine ;
De Silvestri, Annalisa ;
Nichetti, Mara ;
De Cata, Pasquale ;
Rondanelli, Mariangela ;
Chiovato, Luca ;
Calliada, Fabrizio ;
Filice, Carlo ;
Above, Elisabetta ;
Bruno, Raffaele ;
Dellafiore, Carolina ;
Gulminetti, Roberto ;
Lissandrin, Raffaella ;
Lombardi, Andrea ;
Maserati, Renato ;
Michelone, Giuseppe ;
Mondelli, Mario Umberto ;
Novati, Stefano ;
Parisi, Aldo ;
Poma, Gianluigi ;
Sacchi, Paolo ;
Seminari, Elena ;
Zanaboni, Domenico ;
Callea, Giovanni ;
Ciacchini, Benedetti ;
Muzic, Shaun Ivan ;
Savietto, Giovanni ;
Vagni, Domenico .
CLINICAL AND TRANSLATIONAL GASTROENTEROLOGY, 2019, 10 (10)
[8]   QUANTITATIVE ULTRASOUND IN EX VIVO FIBROTIC RABBIT LIVERS [J].
Franceschini, Emilie ;
Escoffre, Jean-Michel ;
Novell, Anthony ;
Auboire, Laurent ;
Mendes, Vanda ;
Benane, Yanis M. ;
Bouakaz, Ayache ;
Basset, Olivier .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (07) :1777-1786
[9]   ULTRASOUND ATTENUATION ESTIMATION IN HARMONIC IMAGING FOR ROBUST FATTY LIVER DETECTION [J].
Gong, Ping ;
Zhou, Chenyun ;
Song, Pengfei ;
Huang, Chengwu ;
Lok, U-Wai ;
Tang, Shanshan ;
Watt, Kymberly ;
Callstrom, Matthew ;
Chen, Shigao .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11) :3080-3087
[10]   System-Independent Ultrasound Attenuation Coefficient Estimation Using Spectra Normalization [J].
Gong, Ping ;
Song, Pengfei ;
Huang, Chengwu ;
Trzasko, Joshua ;
Chen, Shigao .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (05) :867-875