Hemodynamic Performance of Self-Expandable Transcatheter Aortic Valve Replacement Systems During Valve Deployment

被引:1
|
作者
Alperi, Alberto [1 ,2 ]
Moris, Cesar [1 ,2 ]
del Valle, Raquel [1 ]
Pascual, Isaac [2 ]
Antuna, Paula [1 ]
Almendarez, Marcel [1 ]
Hernandez-Vaquero, Daniel [2 ]
Betanzos, Jose Luis [1 ]
Rodes-Cabau, Josep [4 ]
Avanzas, Pablo [1 ,2 ,3 ,5 ]
机构
[1] Univ Hosp Asturias, Ave Roma S-N, Oviedo 33011, Asturias, Spain
[2] Inst Invest Sanitaria Principado Asturias, Oviedo, Spain
[3] Univ Oviedo, Asturias, Spain
[4] Laval Univ, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[5] Ctr Invest Red Enfermedades Cardiovasc CIBERCV, Madrid, Spain
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2024年 / 36卷 / 08期
关键词
Self-Expandable; Transcatheter; Aortic stenosis; Transcatheter Aortic Valve Replacement (TAVR); Heart Valve; Valve Hemodynamic Performance; Transcatheter Heart valve; EARLY OUTCOMES; IMPLANTATION; REGISTRY; EVOLUT;
D O I
10.25270/jic/23.00286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Little is known about valve hemodynamic performance during the Evolut and ACURATE Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and ACURATE Neo (Boston Scientific) systems. Methods This was a single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or ACURATE Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. Results Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P < .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P < .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). Conclusions Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Anatomical Predictors of Valve Malposition During Self-Expandable Transcatheter Aortic Valve Replacement
    Li, Jie
    Sun, Yinghao
    Zheng, Shengneng
    Li, Guang
    Dong, Haojian
    Fu, Ming
    Mo, Yujing
    Li, Yi
    Liu, Huadong
    Xu, Zhaoyan
    Zhang, Liting
    Cao, Yong
    Fan, Ruixin
    Lim, D. Scott
    Luo, Jianfang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [2] Comparison of Hemodynamic Performance of Self-Expandable and Balloon-Expandable Valve in Relation to Aortic Annulus Area in Patients Underwent Transcatheter Aortic Valve Replacement
    Horita, Ryo
    Ota, Mitsuhiko
    Kitai, Takeshi
    Sasaki, Yasuhiro
    Kim, Kitae
    Yamane, Takafumi
    Kobori, Atsushi
    Kinoshita, Makoto
    Kaji, Shuichiro
    Ehara, Natsuhiko
    Koyama, Tadaaki
    Furukawa, Yutaka
    CIRCULATION, 2018, 138
  • [3] Aortic Angulation and Self-Expandable Transcatheter Aortic Valve Replacement Outcomes
    Abramowitz, Yigal
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (11) : 1216 - 1217
  • [4] Transcatheter Self-Expandable Aortic Valve Implantation in the Expandable Surgical Aortic Valve
    Hirota, Masataka
    Domoto, Satoru
    Inagaki, Yusuke
    Yoshikawa, Masafumi
    Yamaguchi, Junichi
    Niinami, Hiroshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (11) : 1397 - 1399
  • [5] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [6] Prosthesis valve dislocation and acute ascending aortic dissection during transcatheter self-expandable aortic valve replacement
    Yamashiro, Satoshi
    Kise, Yuya
    Inafuku, Hitoshi
    Nagano, Takaaki
    Kuniyoshi, Yukio
    CHIRURGIA-ITALY, 2021, 34 (01): : 41 - 43
  • [7] Impact of Repositioning on Outcomes Following Transcatheter Aortic Valve Replacement With a Self-Expandable Valve
    Attizzani, Guilherme F.
    Dallan, Luis Augusto P.
    Markowitz, Alan
    Yakubov, Steven J.
    Deeb, G. Michael
    Reardon, Michael J.
    Forrest, John K.
    Mangi, Abeel A.
    Huang, Jian
    Popma, Jeffrey J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1816 - 1824
  • [8] Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A NationWide Study
    Sa, Young Kyoung
    Choi, Ik Jun
    Chang, Kiyuk
    Hwang, Byung-Hee
    Chung, Woo-Baek
    Lee, Kwan Yong
    Choo, Eun-Ho
    Kim, Chan Joon
    Park, Mahn Won
    Choi, Yoon Seok
    Park, Chul Soo
    Yoo, Ki Dong
    Jeon, Doo Soo
    Oak, Min -Ho
    Lee, Jungkuk
    Kang, Dongwoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 119 - 125
  • [9] Echocardiographic Imaging of Procedural Complications During Self-Expandable Transcatheter Aortic Valve Replacement
    Hahn, Rebecca T.
    Gillam, Linda D.
    Little, Stephen H.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 319 - 336
  • [10] Aortic valve morphology and paravalvular leak regression after a self-expandable transcatheter aortic valve replacement
    Jin, Qinchun
    Li, Wei
    Chen, Shasha
    Li, Mingfei
    Zhou, Daxin
    Zhang, Xiaochun
    Ge, Junbo
    FRONTIERS IN PHYSIOLOGY, 2023, 13