First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

被引:0
作者
Haak, V. [1 ]
Dhard, C. P. [1 ]
Boeyaert, D. [2 ]
Braeuer, T. [1 ]
Bykov, V. [1 ]
Day, C. [3 ]
Degenkolbe, S. [1 ]
Ehrke, G. [1 ]
Igitkhanov, J. [3 ]
Khokhlov, M. [1 ]
Kremeyer, T. [1 ]
Nagel, M. [1 ]
Naujoks, D. [1 ]
Pietsch, M. [1 ]
Pilopp, D. [1 ]
Schlisio, G. [1 ]
Strobel, H. [3 ]
Tantos, C. [3 ]
Varoutis, S. [3 ]
Viebke, H. [1 ]
Volzke, O. [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
[2] Univ Wisconsin Madison, Madison, WI USA
[3] Karlsruhe Inst Technol, D-76344 Eggenstein Leopoldshafen, Germany
关键词
Cryo-vacuum pumping; Particle exhaust; Divertor neutral gas pressure; Stellarator Wendelstein 7-X; DESIGN;
D O I
10.1016/j.fusengdes.2024.114671
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 +/- 1 m(3)/s was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 m(3)/s for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10(-4) mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.
引用
收藏
页数:7
相关论文
共 22 条
  • [21] First results from the implementation of the ITER diagnostic residual gas analyzer prototype at Wendelstein 7-X
    Schlisio, G.
    Klepper, C. C.
    Harris, J. H.
    Biewer, T. M.
    Winters, V. R.
    Wenzel, U.
    Kornejew, P.
    Laqua, H.
    Krychowiak, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (09)
  • [22] Plasma beta effects on the edge magnetic field structure and divertor heat loads in Wendelstein 7-X high-performance scenarios
    Knieps, A.
    Suzuki, Y.
    Geiger, J.
    Dinklage, A.
    Zhou, S.
    Rahbarnia, K.
    Schilling, J.
    Neuner, U.
    Thomsen, H.
    Jakubowski, M.
    Koenig, R.
    Endler, M.
    Gao, Y.
    Sitjes, A. Puig
    Niemann, H.
    Beurskens, M.
    Bozhenkov, S.
    Liang, Y.
    NUCLEAR FUSION, 2022, 62 (02)