Operating Room Air May Harbor Pathogens: The Role of an Ultraviolet Air Filtration Unit

被引:0
|
作者
Fernandez-Rodriguez, Diana [1 ,2 ]
Tarabichi, Saad [3 ]
Golankiewicz, Krystal [1 ]
Zappley, Nicolina [1 ]
Parvizi, Javad [4 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Dept Orthoped Surg, Philadelphia, PA USA
[2] Univ Nacl Autonoma Mexico, Fac Med, Mexico City, Mexico
[3] Mayo Clin Arizona, Dept Orthopaed Surg, Phoenix, AZ USA
[4] Acibadem Univ Hosp, Int Joint Ctr, Istanbul, Turkiye
来源
JOURNAL OF ARTHROPLASTY | 2024年 / 39卷 / 11期
关键词
surgical site infection; arthroplasty; operating room; sterilization; contamination; SURGICAL SITE INFECTIONS; CONTAMINATION; JOINT; SURGERY; HIP; VENTILATION; REPLACEMENT; RADIATION; QUALITY; CARE;
D O I
10.1016/j.arth.2024.05.072
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: One important factor for the prevention of surgical site infections is ultraclean air in the operating room (OR). Still, the direct sterilization potential of most technologies, especially in a dynamic clinical setting, is not well understood. We aimed to determine and compare the microbial presence from the inlet and outlet flow of a filtration unit with crystalline ultraviolet-C (C-UVC) light. Methods: A prospective study was conducted at a single institution, where primary total joint arthroplasty and spine surgeries were performed. The OR was fitted with a positive ventilation system. In addition, a filtration unit with a C-UVC sterilizing light was placed in the OR. The inlet and outlet air flows were swabbed simultaneously and compared. Swabs were processed for culture and next-generation sequencing. Results: The mean length of the surgical procedures sampled was 68 +/- 13 minutes. Overall, 19 out of 200 (9.5%) swabs isolated microorganisms. Inlet air swabs were positive at a higher rate (16 versus 3%; P < .01) compared to the outlet air swabs. A wide variety of Gram-positive, Gram-negative, and anaerobic bacteria were isolated, but fungi were only recovered from inlet air swabs. The detection of microorganisms was also higher when more door openings were performed (32.5 +/- 7.1 versus 27.9 +/- 5.6; P < .01). Conclusions: Air swabs mainly isolated microorganisms from the inlet flow to the filtration unit with a CUVC light. The sterilizing unit counteracted factors affecting the air quality in the OR, namely door openings, surgical personnel, and tissue combustion. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:2857 / 2862
页数:6
相关论文
共 50 条
  • [1] Impact of Filtration Conditions on Air Quality in an Operating Room
    Pereira, Marcelo Luiz
    Vilain, Rogerio
    Kawase, Patricia Rocha
    Tribess, Arlindo
    Morawska, Lidia
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2020, 14 (06) : 685 - 692
  • [2] In-Room Ultraviolet Air Filtration Units Reduce Airborne Particles During Total Joint Arthroplasty
    Anis, Hiba K.
    Curtis, Gannon L.
    Klika, Alison K.
    Piuzzi, Nicolas S.
    Otiso, Joshua
    Richter, Sandra S.
    Barsoum, Wael K.
    Higuera, Carlos A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (02) : 431 - 437
  • [3] The Effect of Laminar Air Flow and Door Openings on Operating Room Contamination
    Smith, Eric B.
    Raphael, Ibrahim J.
    Maltenfort, Mitchell G.
    Honsawek, Sittisak
    Dolan, Kyle
    Younkins, Elizabeth A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1482 - 1485
  • [4] Reduction in Operating Room Airborne Particle Burden and Time- Dependent Contamination of Sterile Instrument Trays With the Use of a Novel Air Filtration System
    Hijji, Fady Y.
    Schneider, Andrew D.
    Reeves, Jeffrey T.
    Wilson, Michael L.
    Nye, Logan
    Lyons, Joseph G.
    Prayson, Michael J.
    Rubino, Louis J.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (07)
  • [5] Role of Operating Room Size on Air Quality in Primary Total Hip Arthroplasty
    Derry, Kendall H.
    Sicat, Chelsea S.
    Shen, Michelle
    Davidovitch, Roy I.
    Schwarzkopf, Ran
    Rozell, Joshua C.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (05): : 935 - 938
  • [6] Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units
    Curtis, Gannon L.
    Faour, Mhamad
    Jawad, Michael
    Klika, Alison K.
    Barsoum, Wael K.
    Higuera, Carlos A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : S196 - S200
  • [7] Many Common Pathogens are Present in the Operative Room Air During Surgery
    Chisari, Emanuele
    Largoza, Garrett
    Clarkson, Samuel
    Krueger, Chad A.
    Kirschman, David
    Parvizi, Javad
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2427 - 2430
  • [8] Impact of Filtration Conditions on Air Quality in an Operating Room
    Marcelo Luiz Pereira
    Rogério Vilain
    Patricia Rocha Kawase
    Arlindo Tribess
    Lidia Morawska
    International Journal of Environmental Research, 2020, 14 : 685 - 692
  • [9] Laminar Air Flow Handling Systems in the Operating Room
    Jain, Sameer
    Reed, Mike
    SURGICAL INFECTIONS, 2019, 20 (02) : 151 - 158
  • [10] Operating Room Traffic Increases Aerosolized Particles and Compromises the Air Quality: A Simulated Study
    Rezapoor, Maryam
    Alvand, Abtin
    Jacek, Elzbieta
    Paziuk, Taylor
    Maltenfort, Mitchell G.
    Parvizi, Javad
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 851 - 855