Development of a multiplex one-tube loop-mediated isothermal amplification method for rapidly simultaneous detection of the mecA and nuc genes in methicillin-resistant Staphylococcus aureus

被引:0
作者
Lee, Jeong-Eun [1 ]
Kim, Sol-A [2 ]
Mun, Hyoyoung [3 ]
Ha, Kwang-Soo [4 ]
Shim, Won-Bo [5 ,6 ]
机构
[1] Gyeongsang Natl Univ, Inst Smart Farm, Jinju 52828, Gyeongnam, South Korea
[2] Gyeongsang Natl Univ, Grad Sch, Div Appl Life Sci, Jinju 52828, Gyeongnam, South Korea
[3] Apteasy MJ inc, BI Ctr, 123 Cheomdangwagi Ro, Gwangju 61005, South Korea
[4] Natl Inst Fisheries Sci, Food Safety & Proc Res Div, Busan 46083, South Korea
[5] Gyeongsang Natl Univ, Inst Agr & Life Sci, Jinju 52828, Gyeongnam, South Korea
[6] Gyeongsang Natl Univ, Div Food Sci & Technol, Jinju 52828, Gyeongnam, South Korea
基金
新加坡国家研究基金会;
关键词
Methicillin-resistant Staphylococcus aureus; Multiplex detection; Colorimetric detection; Loop-mediated isothermal amplification; Graphene oxide; MRSA; LAMP; STRAINS;
D O I
10.1016/j.microc.2024.110712
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study developed a multiplex one-tube loop-mediated isothermal amplification method using fluorescent dye-labeled DNA probes (mfLAMP) for the rapid simultaneous detection of the nuc (S. S. aureus-specific marker) and mecA genes (PBP2a-specific marker) in methicillin-resistant Staphylococcus aureus (MRSA). In the mfLAMP method, a graphene oxide (GO) was used as an effective adsorbent to eliminate free fluorescent dye-labeled DNA probes (mecAf-probe: mecAf- probe: Cy5-ssDNA-Biotin and nucf- probe: FAM-ssDNA-Biotin) present in negative results. The samples were then measured using a developed program that enable simultaneous detection of fluorescein (FAM) and Cyanine5 (Cy5). Green fluorescence represents the detection of the nuc gene, red fluorescence indicates the detection of the mecA gene, and yellow fluorescence signifies the detection of MRSA. The mfLAMP was specific to MRSA and could detect 10 degrees CFU/mL degrees CFU/mL of MRSA in standard buffer and artificially inoculated irrigation water. The recovery rate from contaminated irrigation water ranged from 100.41 to 109.85 %. This study is the first to report the mfLAMP using GO, which could be point-of-care testing for the rapid and simultaneous detection of MRSA's nuc and mecA genes. The results demonstrate that the mfLAMP will be a novel tool for simultaneously detecting more than two target genes or bacteria within 1 h without an enrichment step.
引用
收藏
页数:12
相关论文
共 36 条
  • [1] A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoes
    Aonuma, Hiroka
    Yoshimura, Aya
    Kobayashi, Tomomi
    Okado, Kiyoshi
    Badolo, Athanase
    Nelson, Bryce
    Kanuka, Hirotaka
    Fukumoto, Shinya
    [J]. EXPERIMENTAL PARASITOLOGY, 2010, 125 (02) : 179 - 183
  • [2] Quenching of Unincorporated Amplification Signal Reporters in Reverse-Transcription Loop-Mediated Isothermal Amplification Enabling Bright, Single-Step, Closed-Tube, and Multiplexed Detection of RNA Viruses
    Ball, Cameron S.
    Light, Yooli K.
    Koh, Chung-Yan
    Wheeler, Sarah S.
    Coffey, Lark L.
    Meagher, Robert J.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (07) : 3562 - 3568
  • [3] Guidelines for the laboratory diagnosis and susceptibility testing of methicillin-resistant Staphylococcus aureus (MRSA)
    Brown, DFJ
    Edwards, DI
    Hawkey, PM
    Morrison, D
    Ridgway, GL
    Towner, KJ
    Wren, MWD
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 56 (06) : 1000 - 1018
  • [4] Simultaneous detection of multiple foodborne bacteria by loop-mediated isothermal amplification on a microfluidic chip through colorimetric and fluorescent assay
    Cao, Yanan
    Ye, Cheng
    Zhang, Cong
    Zhang, Guohao
    Hu, Haiming
    Zhang, Zhigang
    Fang, Haitian
    Zheng, Junping
    Liu, Hongtao
    [J]. FOOD CONTROL, 2022, 134
  • [5] Use of antibiotics as feed additives: a burning question
    Chattopadhyay, Madhab K.
    [J]. FRONTIERS IN MICROBIOLOGY, 2014, 5
  • [6] The rapid and visual detection of methicillin-susceptible and methicillin-resistantStaphylococcus aureususing multiplex loop-mediated isothermal amplification linked to a nanoparticle-based lateral flow biosensor
    Chen, Xu
    Ma, Kai
    Yi, Xu
    Xiong, Lijuan
    Wang, Yu
    Li, Shijun
    [J]. ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2020, 9 (01)
  • [7] Rapid detection of mecA and nuc genes in staphylococci by real-time multiplex polymerase chain reaction
    Costa, AM
    Kay, I
    Palladino, S
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2005, 51 (01) : 13 - 17
  • [8] Dashti AA, 2009, KUWAIT MED J, V41, P117
  • [9] The molecular evolution of methicillin-resistant Staphylococcus aureus
    Deurenberg, R. H.
    Vink, C.
    Kalenic, S.
    Friedrich, A. W.
    Bruggeman, C. A.
    Stobberingh, E. E.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2007, 13 (03) : 222 - 235
  • [10] A Loop-Mediated Isothermal Amplification (LAMP) Assay for Early Detection of Schistosoma mansoni in Stool Samples: A Diagnostic Approach in a Murine Model
    Fernandez-Soto, Pedro
    Gandasegui Arahuetes, Javier
    Sanchez Hernandez, Alicia
    Lopez Aban, Julio
    Vicente Santiago, Belen
    Muro, Antonio
    [J]. PLOS NEGLECTED TROPICAL DISEASES, 2014, 8 (09):