Stem Alignment With the Tapered Wedge Cementless Stem "Accolade II" Does Not Affect Bone Mineral Density Over 5 Years After Total Hip Arthroplasty

被引:1
作者
Tsujino, Masashi [1 ]
Iwakiri, Kentaro [1 ]
Ohta, Yoichi [2 ]
Minoda, Yukihide [2 ]
Kobayashi, Akio [1 ]
Nakamura, Hiroaki [2 ]
机构
[1] Shiraniwa Hosp Joint Arthroplasty Ctr, Dept Orthopaed Surg, Ikoma, Nara, Japan
[2] Osaka City Univ, Dept Orthopaed Surg, Grad Sch Med, Osaka, Japan
来源
ARTHROPLASTY TODAY | 2024年 / 27卷
关键词
Bone mineral density; Total hip arthroplasty; Stem alignment; Tapered wedge cementless stem; FOLLOW-UP; PERFORMANCE; FIT;
D O I
10.1016/j.artd.2024.101433
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty. Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems. Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years. Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics. (c) 2024 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:5
相关论文
共 23 条
[1]   Favorable Results of a Short, Tapered, Highly Porous, Proximally Coated Cementless Femoral Stem at a Minimum 4-Year Follow-Up [J].
Albers, Anthony ;
Aoude, Ahmed A. ;
Zukor, David J. ;
Huk, Olga L. ;
Antoniou, John ;
Tanzer, Michael .
JOURNAL OF ARTHROPLASTY, 2016, 31 (04) :824-829
[2]   Efficient computational method for assessing the effects of implant positioning in cementless total hip replacements [J].
Bah, Mamadou T. ;
Nair, Prasanth B. ;
Taylor, Mark ;
Browne, Martin .
JOURNAL OF BIOMECHANICS, 2011, 44 (07) :1417-1422
[3]   The Short and "Shorter" of It: >1750 Tapered Titanium Stems at 6-to 88-Month Follow-Up [J].
Barrington, John W. ;
Emerson, Roger H., Jr. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :38-40
[4]   Biomechanics of a short stem: In vitro primary stability and stress shielding of a conservative cementless hip stem [J].
Bieger, Ralf ;
Ignatius, Anita ;
Reichel, Heiko ;
Duerselen, Lutz .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) :1180-1186
[5]   Short-term success of proximal bone stock preservation in short hip stems: a systematic review of the literature [J].
de Waard, Sheryl ;
van der Vis, Jacqueline ;
Venema, Pascale A. H. T. ;
Sierevelt, Inger N. ;
Kerkhoffs, Gino M. M. J. ;
Haverkamp, Daniel .
EFORT OPEN REVIEWS, 2021, 6 (11) :1040-1051
[6]   Hip and knee replacement 1 Hip replacement [J].
Ferguson, Rory J. ;
Palmer, Antony J. R. ;
Taylor, Adrian ;
Porter, Martyn L. ;
Malchau, Henrik ;
Glyn-Jones, Sion .
LANCET, 2018, 392 (10158) :1662-1671
[7]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[8]   Stem anteversion mismatch to the anatomical anteversion causes loss of periprosthetic bone density after THA [J].
Hayashi, Shinya ;
Hashimoto, Shingo ;
Matsumoto, Tomoyuki ;
Takayama, Koji ;
Nishida, Kotaro ;
Ishida, Kazunari ;
Kuroda, Ryosuke .
JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (03)
[9]   Early performance-based and patientreported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty [J].
Hossain, F. ;
Konan, S. ;
Volpin, A. ;
Haddad, F. S. .
BONE & JOINT JOURNAL, 2017, 99B (04) :49-55
[10]   Difference in Postoperative Periprosthetic Bone Mineral Density Changes Between 3 Major Designs of Uncemented Stems: A 3-Year Follow-Up Study [J].
Inaba, Yutaka ;
Kobayashi, Naomi ;
Oba, Masatoshi ;
Ike, Hiroyuki ;
Kubota, So ;
Saito, Tomoyuki .
JOURNAL OF ARTHROPLASTY, 2016, 31 (08) :1836-1841