Monte Carlo methods for medical imaging research

被引:6
作者
Lee, Hoyeon [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Peoples R China
[2] Univ Hong Kong, Ctr Canc Med, Hong Kong, Peoples R China
关键词
Monte Carlo; Medical imaging; Computational modeling; DIGITAL BREAST TOMOSYNTHESIS; CONE-BEAM CT; SCATTER CORRECTION; SIMULATION TOOL; CONVOLUTION SUPERPOSITION; EXPERIMENTAL-VERIFICATION; COMPUTATIONAL MODEL; COMPUTED-TOMOGRAPHY; GEANT4; SIMULATION; DOSE CALCULATIONS;
D O I
10.1007/s13534-024-00423-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In radiation-based medical imaging research, computational modeling methods are used to design and validate imaging systems and post-processing algorithms. Monte Carlo methods are widely used for the computational modeling as they can model the systems accurately and intuitively by sampling interactions between particles and imaging subject with known probability distributions. This article reviews the physics behind Monte Carlo methods, their applications in medical imaging, and available MC codes for medical imaging research. Additionally, potential research areas related to Monte Carlo for medical imaging are discussed.
引用
收藏
页码:1195 / 1205
页数:11
相关论文
共 179 条
[151]   Investigation of prompt γ ray emission for online monitoring in ion therapy [J].
Steinschaden, D. ;
Brunner, S. E. ;
Dichtl, H. ;
Fuchs, H. ;
Georg, D. ;
Hirtl, A. ;
Marton, J. ;
Pichler, A. .
FAIRNESS 2014: FAIR NEXT GENERATION SCIENTISTS 2014, 2015, 599
[152]   Improved scatter correction using adaptive scatter kernel superposition [J].
Sun, M. ;
Star-Lack, J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6695-6720
[153]   Convolution-based estimation of organ dose in tube current modulated CT [J].
Tian, Xiaoyu ;
Segars, W. Paul ;
Dixon, Robert L. ;
Samei, Ehsan .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (10) :3935-3954
[154]  
Tiwari A, 2019, J NUCL MED, V60
[155]   The AAPM/RSNA physics tutorial for residents - Internal radiation dosimetry: Principles and applications [J].
Toohey, RE ;
Stabin, MG ;
Watson, EE .
RADIOGRAPHICS, 2000, 20 (02) :533-546
[156]  
Torres-Tramon P, 2010, IEEE NUCL SCI CONF R, P3015, DOI 10.1109/NSSMIC.2010.5874351
[157]  
Toussaint M, 2021, IEEE T RADIAT PLASMA, V5, P729, DOI [10.1109/trpms.2020.3033561, 10.1109/TRPMS.2020.3033561]
[158]   Accuracy of weighted CTDI in estimating average dose delivered to CTDI phantoms: An experimental study [J].
Treb, Kevin ;
Li, Ke .
MEDICAL PHYSICS, 2020, 47 (12) :6484-6499
[159]   Geant4 simulations on medical Linac operation at 18 MV: Experimental validation based on activation foils [J].
Vagena, E. ;
Stoulos, S. ;
Manolopoulou, M. .
RADIATION PHYSICS AND CHEMISTRY, 2016, 120 :89-97
[160]   Experimental validation of Monte Carlo dosimetry for therapeutic beta emitters with radiochromic film in a 3D-printed phantom [J].
Van, Benjamin ;
Dewaraja, Yuni K. ;
Niedbala, Jeremy T. ;
Rosebush, Gerrid ;
Kazmierski, Matthew ;
Hubers, David ;
Mikell, Justin K. ;
Wilderman, Scott J. .
MEDICAL PHYSICS, 2023, 50 (01) :540-556