Monte Carlo methods for medical imaging research

被引:6
作者
Lee, Hoyeon [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Diagnost Radiol, Hong Kong, Peoples R China
[2] Univ Hong Kong, Ctr Canc Med, Hong Kong, Peoples R China
关键词
Monte Carlo; Medical imaging; Computational modeling; DIGITAL BREAST TOMOSYNTHESIS; CONE-BEAM CT; SCATTER CORRECTION; SIMULATION TOOL; CONVOLUTION SUPERPOSITION; EXPERIMENTAL-VERIFICATION; COMPUTATIONAL MODEL; COMPUTED-TOMOGRAPHY; GEANT4; SIMULATION; DOSE CALCULATIONS;
D O I
10.1007/s13534-024-00423-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In radiation-based medical imaging research, computational modeling methods are used to design and validate imaging systems and post-processing algorithms. Monte Carlo methods are widely used for the computational modeling as they can model the systems accurately and intuitively by sampling interactions between particles and imaging subject with known probability distributions. This article reviews the physics behind Monte Carlo methods, their applications in medical imaging, and available MC codes for medical imaging research. Additionally, potential research areas related to Monte Carlo for medical imaging are discussed.
引用
收藏
页码:1195 / 1205
页数:11
相关论文
共 179 条
[1]   Virtual clinical trials in medical imaging: a review [J].
Abadi, Ehsan ;
Segars, William P. ;
Tsui, Benjamin M. W. ;
Kinahan, Paul E. ;
Bottenus, Nick ;
Frangi, Alejandro F. ;
Maidment, Andrew ;
Lo, Joseph ;
Samei, Ehsan .
JOURNAL OF MEDICAL IMAGING, 2020, 7 (04)
[2]  
Abdul Haneefa K., 2014, Journal of Radiotherapy, V2014
[3]   Algebraic reconstruction technique combined with Monte Carlo method for weight matrix calculation in gamma ray transmission tomography [J].
Agarwal, Chhavi ;
Mhatre, Amol ;
Patra, Sabyasachi ;
Chaudhury, Sanhita ;
Goswami, A. .
SN APPLIED SCIENCES, 2019, 1 (10)
[4]   A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors [J].
Ahmed, Abdella M. ;
Chacon, Andrew ;
Rutherford, Harley ;
Akamatsu, Go ;
Mohammadi, Akram ;
Nishikido, Fumihiko ;
Tashima, Hideaki ;
Yoshida, Eiji ;
Yamaya, Taiga ;
Franklin, Daniel R. ;
Rosenfeld, Anatoly ;
Guatelli, Susanna ;
Safavi-Naeini, Mitra .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
[5]   Generation and use of photon energy deposition kernels for diagnostic quality x rays [J].
Alaei, P ;
Gerbi, BJ ;
Geise, RA .
MEDICAL PHYSICS, 1999, 26 (08) :1687-1697
[6]   Investigation of SPECT/CT cardiac imaging using Geant4 [J].
Alfuraih, A. ;
Kadri, O. ;
Alzimami, K. .
NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (07)
[7]   Computational scatter correction in near real-time with a fast Monte Carlo photon transport model for high-resolution flat-panel CT [J].
Alsaffar, Ammar ;
Kiess, Steffen ;
Sun, Kaicong ;
Simon, Sven .
JOURNAL OF REAL-TIME IMAGE PROCESSING, 2022, 19 (06) :1063-1079
[8]   Experimental verification of convolution /superposition photon dose calculations for radiotherapy treatment planning [J].
Aspradakis, MM ;
Morrison, RH ;
Richmond, ND ;
Steele, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17) :2873-2893
[9]   Monte Carlo simulation in PET and SPECT instrumentation using GATE [J].
Assié, K ;
Breton, V ;
Buvat, I ;
Comtat, C ;
Jan, S ;
Krieguer, M ;
Lazaro, D ;
Morel, C ;
Rey, M ;
Santin, G ;
Simon, L ;
Staelens, S ;
Strul, D ;
Vieira, JM ;
Van de Walle, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) :180-189
[10]   An overview of recent developments in FLUKA PET TOOLS [J].
Augusto, R. S. ;
Bauer, J. ;
Bouhali, O. ;
Cuccagna, C. ;
Gianoli, C. ;
Kozlowska, W. S. ;
Ortega, P. G. ;
Tessonnier, T. ;
Toufique, Y. ;
Vlachoudis, V. ;
Parodi, K. ;
Ferrari, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 :189-199