Sensitivity of Chitosan Film Based Electrode Modified with Reduced Graphene Oxide (rGO) for Formaldehyte Detection Using Cyclic Voltammetry

被引:4
作者
Nainggolan, Irwana [1 ]
Saisa [1 ,2 ]
Agusnar, Harry [1 ]
Alfian, Zul [1 ]
Alva, Sagir [3 ]
Nasution, Tulus Ikhsan [4 ]
Rahman, Rozyanty [5 ]
Sembiring, Ardiansyah [1 ]
机构
[1] Univ Sumatera Utara, Fac Math & Nat Sci, Dept Chem, Medan 20155, Sumatera Utara, Indonesia
[2] Univ Serambi Mekkah, Fac Engn, Dept Chem Engn, Banda Aceh 23245, Aceh, Indonesia
[3] Univ Mercu Buana, Fac Engn, Dept Mech Engn, West Jakarta, Indonesia
[4] Univ Sumatera Utara, Fac Math & Nat Sci, Dept Phys, Medan 20155, Sumatera Utara, Indonesia
[5] Univ Malaysia Perlis, Ctr Excellence Geopolymer & Green Technol, Sch Mat Engn, Jejawi 02600, Perlis, Malaysia
关键词
Chitosan; Cyclic voltammetry; Electrochemistry; Reduced graphene oxide; Working electrode; GAS SENSOR; NANOPARTICLES; SONICATION;
D O I
10.1016/j.sajce.2024.02.001
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper reports the ability of chitosan-reduced graphene oxide (rGO) modified electrode as a sensitive layer of working electrode in detecting formaldehyde. The electrode substrate is in the form of copper-SPE which has been shaped into 5 mm of sensitive area. On top of the working electrode, a number of chitosan and chitosanreduced graphene oxide (rGO) matrices were placed in the form of a thin film layer that works as a working electrode. Characterization of chitosan and chitosan-reduced graphene oxide (rGO) thin films was done using SEM, TEM, AFM and FTIR. The test for electrochemical sensing ability of working electrode was observed using cyclic voltammetry (CV), whereas chitosan and chitosan-rGO films were deposited onto the surface of working electrodes. The novelty of this research is the utilization of chitosan-rGO thin film based working electrode for detecting formaldehyde. The testing results showed sensitivity and response of working electrode increased when chitosan-reduced graphene oxide modified electrode was used for formaldehyde detection compared to chitosan film based working electrode. It was proven from the sensitivity value of chitosan-rGO based working electrode at the lowest value of 4.6 x 10-4 mu A/mu M and linear range at 1-12 x 10-4 mu M/L, as well as the ability of chitosanrGO based working electrode which worked at limit of detection (LoD) 0.36 mu M/L and limit of quantification (LoQ) 1.21 mu M/L.
引用
收藏
页码:184 / 193
页数:10
相关论文
共 50 条
[21]   Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection [J].
Szoke, A. ;
Turdean, G. ;
Muresan, L. .
BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 :147-154
[22]   An electrochemical sensor based on MnO2 nanostructures modified reduced graphene oxide (rGO) for detection of dopamine [J].
Lu, Meng ;
Luo, Wenzhao ;
Zhou, Yuhui ;
Wu, Mishan .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (10) :1-13
[23]   A sensitive biosensor for cyanide detection using modified glassy carbon electrode with reduced graphene oxide and immobilization of horseradish peroxidase [J].
Ghanavati, Mahdi ;
Moraveji, Mostafa Keshavarz ;
Iranshahi, Davood .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 102 (03) :1031-1038
[24]   Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide (ERGO) Modified Electrode [J].
Jeyapragasam, Tharini ;
Saraswathi, Ramiah ;
Chen, Shen-Ming ;
Lou, Bih-Show .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (11) :12353-12366
[25]   Study on the specific capacitance of an activated carbon cloth modified with reduced graphene oxide and polyaniline by cyclic voltammetry [J].
Fernandez, J. ;
Bonastre, J. ;
Molina, J. ;
del Rio, A. I. ;
Cases, F. .
EUROPEAN POLYMER JOURNAL, 2017, 92 :194-203
[26]   Graphene electrode modified with electrochemically reduced graphene oxide for label-free DNA detection [J].
Li, Bing ;
Pan, Genhua ;
Avent, Neil D. ;
Lowry, Roy B. ;
Madgett, Tracey E. ;
Waines, Paul L. .
BIOSENSORS & BIOELECTRONICS, 2015, 72 :313-319
[27]   Comparative Study on Electroanalysis of Fenthion Using Silver Amalgam Film Electrode and Glassy Carbon Electrode Modified with Reduced Graphene Oxide [J].
Smarzewska, Sylwia ;
Metelka, Radovan ;
Festinger, Natalia ;
Guziejewski, Dariusz ;
Ciesielski, Witold .
ELECTROANALYSIS, 2017, 29 (04) :1154-1160
[28]   Effect and investigating of oxygen / nitrogen on modified glassy carbon electrode chitosan/carbon nanotube and best detection of nicotine using Cyclic voltammetry measurement technique [J].
Mirani, Abolfazl ;
Rheima, Ahmed Mahdi ;
Turki, Zainab talib ;
Jawad, Sabrean Farhan ;
Athair, Duaa Mohammed ;
Al-Sharify, Zainab T. ;
Esmaili, Mohammadreza ;
Sayadi, Hamidreza ;
Kianfar, Ehsan .
RESULTS IN CHEMISTRY, 2024, 10
[29]   A Reusable Nickel Oxide Reduced Graphene Oxide Modified Platinum Electrode for the Detection of Linezolid Drug [J].
Buledi, Jamil A. ;
Solangi, Amber R. ;
Mallah, Arfana ;
Hassan, Syeda Sara ;
Ameen, Sidra ;
Karaman, Ceren ;
Karimi-Maleh, Hassan .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (11) :4665-4675
[30]   Smartphone-based cyclic voltammetry system with graphene modified screen printed electrodes for glucose detection [J].
Ji, Daizong ;
Liu, Lei ;
Li, Shuang ;
Chen, Chen ;
Lu, Yanli ;
Wu, Jiajia ;
Liu, Qingjun .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :449-456