Sensitivity of Chitosan Film Based Electrode Modified with Reduced Graphene Oxide (rGO) for Formaldehyte Detection Using Cyclic Voltammetry

被引:3
|
作者
Nainggolan, Irwana [1 ]
Saisa [1 ,2 ]
Agusnar, Harry [1 ]
Alfian, Zul [1 ]
Alva, Sagir [3 ]
Nasution, Tulus Ikhsan [4 ]
Rahman, Rozyanty [5 ]
Sembiring, Ardiansyah [1 ]
机构
[1] Univ Sumatera Utara, Fac Math & Nat Sci, Dept Chem, Medan 20155, Sumatera Utara, Indonesia
[2] Univ Serambi Mekkah, Fac Engn, Dept Chem Engn, Banda Aceh 23245, Aceh, Indonesia
[3] Univ Mercu Buana, Fac Engn, Dept Mech Engn, West Jakarta, Indonesia
[4] Univ Sumatera Utara, Fac Math & Nat Sci, Dept Phys, Medan 20155, Sumatera Utara, Indonesia
[5] Univ Malaysia Perlis, Ctr Excellence Geopolymer & Green Technol, Sch Mat Engn, Jejawi 02600, Perlis, Malaysia
关键词
Chitosan; Cyclic voltammetry; Electrochemistry; Reduced graphene oxide; Working electrode; GAS SENSOR; NANOPARTICLES; SONICATION;
D O I
10.1016/j.sajce.2024.02.001
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper reports the ability of chitosan-reduced graphene oxide (rGO) modified electrode as a sensitive layer of working electrode in detecting formaldehyde. The electrode substrate is in the form of copper-SPE which has been shaped into 5 mm of sensitive area. On top of the working electrode, a number of chitosan and chitosanreduced graphene oxide (rGO) matrices were placed in the form of a thin film layer that works as a working electrode. Characterization of chitosan and chitosan-reduced graphene oxide (rGO) thin films was done using SEM, TEM, AFM and FTIR. The test for electrochemical sensing ability of working electrode was observed using cyclic voltammetry (CV), whereas chitosan and chitosan-rGO films were deposited onto the surface of working electrodes. The novelty of this research is the utilization of chitosan-rGO thin film based working electrode for detecting formaldehyde. The testing results showed sensitivity and response of working electrode increased when chitosan-reduced graphene oxide modified electrode was used for formaldehyde detection compared to chitosan film based working electrode. It was proven from the sensitivity value of chitosan-rGO based working electrode at the lowest value of 4.6 x 10-4 mu A/mu M and linear range at 1-12 x 10-4 mu M/L, as well as the ability of chitosanrGO based working electrode which worked at limit of detection (LoD) 0.36 mu M/L and limit of quantification (LoQ) 1.21 mu M/L.
引用
收藏
页码:184 / 193
页数:10
相关论文
共 50 条
  • [1] Sensitivity of chitosan/reduced graphene oxide/manganese dioxide modified electrodes for cholesterol detection using cyclic voltammetry
    Nainggolan, Irwana
    Martina, Sake Juli
    Alva, Sagir
    Li, Bing
    Nasution, Tulus Ikhsan
    Sembiring, Ardiansyah
    Duha, Athaya Samira
    Saisa, Saisa
    Rahman, Rozyanty
    Asrosa, Rica
    SOUTH AFRICAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 48 : 329 - 336
  • [2] Electrochemical Detection of Xanthine and Study for the Inhibition of Uric Acid Based on Chitosan/Nitrogen Doped Reduced Graphene Oxide Modified Electrode
    Song, Guangjie
    Wu, Tiaodi
    Liu, Fuxin
    Zhang, Binyan
    Liu, Xiuhui
    ACTA CHIMICA SINICA, 2020, 78 (01) : 82 - 88
  • [3] Improved Electrochemical Detection of Zinc Ions Using Electrode Modified with Electrochemically Reduced Graphene Oxide
    Kudr, Jiri
    Richtera, Lukas
    Nejdl, Lukas
    Xhaxhiu, Kledi
    Vitek, Petr
    Rutkay-Nedecky, Branislav
    Hynek, David
    Kopel, Pavel
    Adam, Vojtech
    Kizek, Rene
    MATERIALS, 2016, 9 (01):
  • [4] Synthesizing Graphene Oxide as a Working Electrode Using Cyclic Voltammetry
    Amireza, Aldwin
    Setiarso, Pirim
    PROCEEDINGS OF THE SEMINAR NASIONAL KIMIA - NATIONAL SEMINAR ON CHEMISTRY (SNK 2018), 2018, 171 : 106 - 110
  • [5] Impedance immunosensor for bovine interleukin-4 using an electrode modified with reduced graphene oxide and chitosan
    Chen, Xiang
    Qin, Piya
    Li, Juan
    Yang, Zhanjun
    Wen, Zhifa
    Jian, Zhiqin
    Zhao, Jie
    Hu, Xiaoya
    Jiao, Xin'an
    MICROCHIMICA ACTA, 2015, 182 (1-2) : 369 - 376
  • [6] Detection of formaldehyde by cyclic voltammetry using a PANI/GO composite film-modified electrode
    Wang, Yan-Fang
    Liu, De-Li
    Han, Jia-Jun
    Guo, Ao-Ran
    IONICS, 2022, 28 (05) : 2457 - 2468
  • [7] Tyrosinase/Chitosan/Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for Sensitive and Interference-Free Detection of Dopamine
    Liu, Cheng-You
    Chou, Yi-Chieh
    Tsai, Jui-Hsuan
    Huang, Tzu-Ming
    Chen, Jian-Zhang
    Yeh, Yi-Chun
    APPLIED SCIENCES-BASEL, 2019, 9 (04):
  • [8] A Novel Biosensor Based on Acetylecholinesterase/Chitosan-Graphene Oxide Modified Electrode for Detection of Carbaryl Pesticides
    Li, Pengcheng
    Song, Yonghai
    Chen, Souhui
    Zhang, Mei
    Wang, Li
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (08) : 4444 - 4448
  • [9] Electrochemical Detection of Alloxan on Reduced Graphene oxide Modified Glassy Carbon Electrode
    Paramasivam, Selvaraj
    Raju, Chikkili Venkateswara
    Hemalatha, Sandu
    Mathiyarasu, Jayaraman
    Kumar, Shanmugam Senthil
    ELECTROANALYSIS, 2020, 32 (06) : 1273 - 1279
  • [10] Enhancing the sensitivity and selectivity of salbutamol detection using reduced graphene oxide combined with molecularly imprinted polymers (RGO/MIP)
    Limthin, Dalawan
    Leepheng, Piyawan
    Onlaor, Korakot
    Tunhoo, Benchapol
    Klamchuen, Annop
    Thiwawong, Thutiyaporn
    Phromyothin, Darinee
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SD)