Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review

被引:3
作者
Dassen, Sophie [1 ]
Monen, Loes [1 ]
Oei, Guid [2 ]
Mischi, Massimo
van Laar, Judith [1 ]
机构
[1] Maxima Med Ctr, Obstet & Gynecol, Run 4600, NL-5500 MB Veldhoven, Netherlands
[2] Tech Univ Eindhoven, Fundamental Perinatol, Eindhoven, Netherlands
来源
ULTRASCHALL IN DER MEDIZIN | 2025年 / 46卷 / 03期
关键词
ultrasonography; contrast-enhanced ultrasound; microbubbles; safety; pregnancy; FETAL-GROWTH RESTRICTION; PLACENTAL BLOOD-FLOW; AGENT; ULTRASONOGRAPHY; PERFUSION; INSIGHTS; PRINCIPLES; DOPPLER; BARRIER; MODEL;
D O I
10.1055/a-2351-0747
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Introduction Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date. Material and Methods A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes. Results A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described. Conclusion Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 51 条
[1]  
[Anonymous], Study Quality Assessment Tools | NHLBI
[2]   Comparative determination of placental perfusion by magnetic resonance imaging and contrast-enhanced ultrasound in a murine model of intrauterine growth restriction [J].
Arthuis, C. -J. ;
Mendes, V. ;
Meme, S. ;
Meme, W. ;
Rousselot, C. ;
Winer, N. ;
Novell, A. ;
Perrotin, F. .
PLACENTA, 2018, 69 :74-81
[3]   New insights into uteroplacental perfusion: Quantitative analysis using Doppler and contrast-enhanced ultrasound imaging [J].
Arthuis, C. J. ;
Novell, A. ;
Escoffre, J. -M. ;
Patat, F. ;
Bouakaz, A. ;
Perrotin, F. .
PLACENTA, 2013, 34 (05) :424-431
[4]   IMAGING METHODS FOR ULTRASOUND CONTRAST AGENTS [J].
Averkiou, Michalakis A. ;
Bruce, Matthew F. ;
Powers, Jeffry E. ;
Sheeran, Paul S. ;
Burns, Peter N. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (03) :498-517
[5]  
Baumfeld Y, 2017, TAIWAN J OBSTET GYNE, V56, P331, DOI [10.1016/j.tjog.2017.04.012, 10.1016/j.tjog.2017.05.012]
[6]   Contrast-enhanced ultrasonography of the placental barrier; the protective umbrella of the fetus during pregnancy [J].
Chen, Qingzi ;
Zhang, Lishao ;
Li, Tianti ;
Chen, Shaoqi .
MEDICAL ULTRASONOGRAPHY, 2022, 24 (04) :427-433
[7]  
CHMP, SONOVUE INN SULPHUR
[8]   Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts [J].
Correas, JM ;
Bridal, L ;
Lesavre, A ;
Méjean, A ;
Claudon, M ;
Hélénon, O .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1316-1328
[9]   Ultrasound microbubble contrast angiography in monochorionic twin fetuses [J].
Denbow, ML ;
Blomley, MJK ;
Cosgrove, DO ;
Fisk, NM .
LANCET, 1997, 349 (9054) :773-773
[10]   Twin fetuses: Intravascular microbubble US contrast agent administration - Early experience [J].
Denbow, ML ;
Welsh, AW ;
Taylor, MJ ;
Blomley, MJK ;
Cosgrove, DO ;
Fisk, NM .
RADIOLOGY, 2000, 214 (03) :724-728