Pulmonary vein isolation using pulsed field ablation vs. high-power short-duration radiofrequency ablation in paroxysmal atrial fibrillation: efficacy, safety, and long-term follow-up (PRIORI study)

被引:3
|
作者
Reinsch, Nico [1 ,2 ]
Fueting, Anna [1 ,2 ]
Hartl, Stefan [1 ,2 ]
Hoewel, Dennis [2 ,3 ]
Rausch, Eva [1 ,2 ]
Lin, Yali [1 ,2 ]
Kasparian, Karampet [1 ,2 ,4 ]
Neven, Kars [1 ,2 ]
机构
[1] Alfried Krupp Hosp, Dept Electrophysiol, Alfried Krupp Str 21, D-45131 Essen, Germany
[2] Witten Herdecke Univ, Dept Med, Alfred Herrhausen Str 50, D-58448 Witten, Germany
[3] St Marienhosp Vechta, Dept Cardiol, Vechta, Germany
[4] Alfried Krupp Hosp, Dept Oncol Gastroenterol & Hematol, Essen, Germany
来源
EUROPACE | 2024年 / 26卷 / 07期
关键词
Pulsed field ablation; Pulmonary vein isolation; Atrial fibrillation; High-power short-duration ablation; Ablation index; CATHETER ABLATION; THERAPY;
D O I
10.1093/europace/euae194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pulsed field ablation (PFA) is a novel, non-thermal, cardiac tissue-selective ablation modality. To date, radiofrequency (RF)-guided high-power short-duration (HPSD) ablation represents the gold standard besides cryo-ablation for pulmonary vein isolation (PVI). This single-centre, retrospective study investigated the efficacy of PFA-PVI vs. HPSD-RF PVI in terms of single-procedure arrhythmia-free outcome and safety in a real-world setting. Methods and results Consecutive, paroxysmal atrial fibrillation (AF) patients who underwent PVI using PFA or HPSD-RF were enrolled. In group PFA, PVI was performed using a pentaspline PFA catheter. The ablation procedure in group HPSD-RF was performed with RF energy (45 W, ablation index). A total of 410 patients (group PFA, 201; group HPSD-RF, 209) were included. There was no difference between both groups regarding age, gender, and CHA(2)DS(2)-VASc score. The procedure time was significantly shorter in group PFA [61 (44-103) vs. 125 (105-143) min; P < 0.001]; fluoroscopy time and dose area product were significantly higher in group PFA [16 (13-20) vs. 4 (2-5) min; P < 0.01 and 412 (270-739) vs. 129 (58-265) mu Gym(2); P < 0.01]. The overall complication rates were 2.9% in group PFA and 6.2% in group HPSD (P = 0.158). There was one fatal stroke in the PFA group. The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 85% with PFA and 79% with HPSD-RF (log-rank P = 0.160). In 56 repeat ablation procedures, the PV reconnection rate was 30% after PFA and 38% after HPSD-RF (P = 0.372). Conclusion Both PFA and HPSD-RF were highly efficient and effective in achieving PVI in paroxysmal AF patients. The arrhythmia-free survival is comparable. The PV reconnection rate was not different.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Multicenter prospective comparison of conventional and high-power short duration radiofrequency application for pulmonary vein isolation: the high-power short-duration radiofrequency application for faster and safer pulmonary vein ablation (POWER FAST III) trial
    Castrejon-Castrejon, Sergio
    Cossiani, Marcel Martinez
    Jauregui-Abularach, Miguel
    Sola, Nuria Basterra
    Criado, Jose Luis Ibanez
    Asensi, Joaquin Osca
    Luque, Ivo Roca
    Mitjans, Angel Moya
    Dorador, Aurelio Quesada
    Olivares, Victor Manuel Hidalgo
    Castellano, Nicasio Perez
    Gomez, Juan Manuel Fernandez
    Macias-Ruiz, Maria Rosa
    Villanueva, Bruno Bochard
    Bada, Nerea Gonzalo
    Prieto, Andres Fernandez
    Lopez, Leonardo Elias Guido
    Maldonado, Maria Eugenia Martinez
    Merino, Daniel
    Cervantes, Carlos Escobar
    Merino, Jose Luis
    OWER FAST III trial invest
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1889 - 1899
  • [42] High-power short-duration ablation index–guided pulmonary vein isolation protocol using a single catheter
    Patrick Badertscher
    Sven Knecht
    Florian Spies
    Gian Völlmin
    Beat Schaer
    Nicolas Schärli
    Flurina Bosshard
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 633 - 642
  • [43] Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study
    Castrejon-Castrejon, Sergio
    Martinez Cossiani, Marcel
    Ortega Molina, Marta
    Escobar, Carlos
    Froilan Torres, Consuelo
    Gonzalo Bada, Nerea
    Diaz de la Torre, Marta
    Suarez Parga, Jose Manuel
    Lopez Sendon, Jose Luis
    Luis Merino, Jose
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (01) : 57 - 65
  • [44] Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study
    Sergio Castrejón-Castrejón
    Marcel Martínez Cossiani
    Marta Ortega Molina
    Carlos Escobar
    Consuelo Froilán Torres
    Nerea Gonzalo Bada
    Marta Díaz de la Torre
    José Manuel Suárez Parga
    José Luis López Sendón
    José Luis Merino
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 57 - 65
  • [45] Impact of High-Power and Very High-Power Short-Duration Radiofrequency Ablation on Procedure Characteristics and First-Pass Isolation During Pulmonary Vein Isolation
    Sallo, Zoltan
    Perge, Peter
    Balogi, Bernadett
    Orban, Gabor
    Piros, Katalin
    Herczeg, Szilvia
    Nagy, Klaudia Vivien
    Osztheimer, Istvan
    abraham, Pal
    Merkely, Bela
    Geller, Laszlo
    Szegedi, Nandor
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [46] Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials
    Amin, Ahmed Mazen
    Ghaly, Ramy
    Ibrahim, Ahmed A.
    Ali, Mohamed Ahmed
    Almaadawy, Omar
    Elzahaby, Amr
    Abuelazm, Mohamed
    Abdelazeem, Basel
    Munir, Muhammad Bilal
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (06) : 1445 - 1461
  • [47] Efficacy and Safety of High-power Short-duration Radio Frequency Ablation in the Treatment of Atrial Fibrillation: A Meta-analysis of Prospective Study
    Ma, Guohua
    Zhang, Weijiang
    HEART SURGERY FORUM, 2024, 27 (02) : E188 - E198
  • [48] Safety of very high-power short-duration radiofrequency ablation for pulmonary vein isolation: a two-centre report with emphasis on silent oesophageal injury
    Halbfass, Philipp
    Wielandts, Jean-Yves
    Knecht, Sebastien
    de Waroux, Jean-Benoit Le Polain
    Tavernier, Rene
    De Wilde, Vincent
    Sonne, Kai
    Nentwich, Karin
    Ene, Elena
    Berkovitz, Artur
    Mueller, Julian
    Lehmkuhl, Lukas
    Reichart, Amelie
    Lusebrink, Ulrich
    Duytschaever, Mattias
    Deneke, Thomas
    EUROPACE, 2022, 24 (03): : 400 - 405
  • [49] High-power short-duration ablation index-guided pulmonary vein isolation protocol using a single catheter
    Badertscher, Patrick
    Knecht, Sven
    Spies, Florian
    Vollmin, Gian
    Schaer, Beat
    Scharli, Nicolas
    Bosshard, Flurina
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (03) : 633 - 642
  • [50] Sex differences in overweight and obese patients undergoing high-power short-duration pulmonary vein isolation for atrial fibrillation: an observational cohort study
    Weyand, Sebastian
    Adam, Viola
    Biehler, Paloma
    Haegele, Patricia
    Hanger, Simon
    Loebig, Stephanie
    Pinchuk, Andrei
    Ausbuettel, Felix
    Waechter, Christian
    Seizer, Peter
    SCIENTIFIC REPORTS, 2024, 14 (01):