Pulmonary vein isolation using pulsed field ablation vs. high-power short-duration radiofrequency ablation in paroxysmal atrial fibrillation: efficacy, safety, and long-term follow-up (PRIORI study)

被引:3
|
作者
Reinsch, Nico [1 ,2 ]
Fueting, Anna [1 ,2 ]
Hartl, Stefan [1 ,2 ]
Hoewel, Dennis [2 ,3 ]
Rausch, Eva [1 ,2 ]
Lin, Yali [1 ,2 ]
Kasparian, Karampet [1 ,2 ,4 ]
Neven, Kars [1 ,2 ]
机构
[1] Alfried Krupp Hosp, Dept Electrophysiol, Alfried Krupp Str 21, D-45131 Essen, Germany
[2] Witten Herdecke Univ, Dept Med, Alfred Herrhausen Str 50, D-58448 Witten, Germany
[3] St Marienhosp Vechta, Dept Cardiol, Vechta, Germany
[4] Alfried Krupp Hosp, Dept Oncol Gastroenterol & Hematol, Essen, Germany
来源
EUROPACE | 2024年 / 26卷 / 07期
关键词
Pulsed field ablation; Pulmonary vein isolation; Atrial fibrillation; High-power short-duration ablation; Ablation index; CATHETER ABLATION; THERAPY;
D O I
10.1093/europace/euae194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pulsed field ablation (PFA) is a novel, non-thermal, cardiac tissue-selective ablation modality. To date, radiofrequency (RF)-guided high-power short-duration (HPSD) ablation represents the gold standard besides cryo-ablation for pulmonary vein isolation (PVI). This single-centre, retrospective study investigated the efficacy of PFA-PVI vs. HPSD-RF PVI in terms of single-procedure arrhythmia-free outcome and safety in a real-world setting. Methods and results Consecutive, paroxysmal atrial fibrillation (AF) patients who underwent PVI using PFA or HPSD-RF were enrolled. In group PFA, PVI was performed using a pentaspline PFA catheter. The ablation procedure in group HPSD-RF was performed with RF energy (45 W, ablation index). A total of 410 patients (group PFA, 201; group HPSD-RF, 209) were included. There was no difference between both groups regarding age, gender, and CHA(2)DS(2)-VASc score. The procedure time was significantly shorter in group PFA [61 (44-103) vs. 125 (105-143) min; P < 0.001]; fluoroscopy time and dose area product were significantly higher in group PFA [16 (13-20) vs. 4 (2-5) min; P < 0.01 and 412 (270-739) vs. 129 (58-265) mu Gym(2); P < 0.01]. The overall complication rates were 2.9% in group PFA and 6.2% in group HPSD (P = 0.158). There was one fatal stroke in the PFA group. The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 85% with PFA and 79% with HPSD-RF (log-rank P = 0.160). In 56 repeat ablation procedures, the PV reconnection rate was 30% after PFA and 38% after HPSD-RF (P = 0.372). Conclusion Both PFA and HPSD-RF were highly efficient and effective in achieving PVI in paroxysmal AF patients. The arrhythmia-free survival is comparable. The PV reconnection rate was not different.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Leshem, Eran
    Buxton, Alfred E.
    Nakagawa, Hiroshi
    Anter, Elad
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) : 1287 - 1296
  • [2] Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation
    Park, Je-Wook
    Yang, Song-Yi
    Kim, Min
    Yu, Hee Tae
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [3] Impact of High-Power Short-Duration Radiofrequency Ablation on Long-Term Lesion Durability for Atrial Fibrillation Ablation
    Yavin, Hagai D.
    Leshem, Eran
    Shapira-Daniels, Ayelet
    Sroubek, Jakub
    Barkagan, Michael
    Haffajee, Charles, I
    Cooper, Joshua M.
    Anter, Elad
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (08) : 973 - 985
  • [4] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Jonas Wörmann
    Jakob Lüker
    Jan-Hendrik van den Bruck
    Karlo Filipovic
    Susanne Erlhöfer
    Cornelia Scheurlen
    Sebastian Dittrich
    Jan-Hendrik Schipper
    Daniel Steven
    Arian Sultan
    Clinical Research in Cardiology, 2023, 112 : 846 - 852
  • [5] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Woermann, Jonas
    Lueker, Jakob
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Erlhoefer, Susanne
    Scheurlen, Cornelia
    Dittrich, Sebastian
    Schipper, Jan-Hendrik
    Steven, Daniel
    Sultan, Arian
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (06) : 846 - 852
  • [6] Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kottmaier, Marc
    Popa, Miruna
    Bourier, Felix
    Reents, Tilko
    Cifuentes, Jairo
    Semmler, Verena
    Telishevska, Martha
    Otgonbayar, Ulamnemekh
    Koch-Buettner, Katharina
    Lennerz, Carsten
    Bartkowiak, Marcin
    Kornmayer, Marielouise
    Rousseva, Elena
    Brkic, Amir
    Grebmer, Christian
    Kolb, Christoph
    Hessling, Gabriele
    Deisenhofer, Isabel
    EUROPACE, 2020, 22 (03): : 388 - 393
  • [7] Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation
    Mueller, Julian
    Nentwich, Karin
    Berkovitz, Artur
    Ene, Elena
    Sonne, Kai
    Zhuravlev, Vitaly
    Chakarov, Ivaylo
    Barth, Sebastian
    Waechter, Christian
    Behnes, Michael
    Halbfass, Philipp
    Deneke, Thomas
    EUROPACE, 2023, 25 (04): : 1379 - 1391
  • [8] Efficacy and safety of pulmonary vein isolation with pulsed field ablation vs. novel cryoballoon ablation system for atrial fibrillation
    Badertscher, Patrick
    Weidlich, Simon
    Knecht, Sven
    Stauffer, Niklas
    Krisai, Philipp
    Voellmin, Gian
    Osswald, Stefan
    Sticherling, Christian
    Kuhne, Michael
    EUROPACE, 2023, 25 (12):
  • [9] Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience
    Dello Russo, Antonio
    Compagnucci, Paolo
    Anselmino, Matteo
    Schillaci, Vincenzo
    Campanelli, Francesca
    Ascione, Maria Rosaria
    Volpato, Giovanni
    Cipolletta, Laura
    Parisi, Quintino
    Valeri, Yari
    D'Angelo, Leonardo
    Chiariello, Paola
    Casella, Michela
    Solimene, Francesco
    HEART RHYTHM, 2024, 21 (09) : 1526 - 1536
  • [10] Effect of Left Atrial Pulmonary Vein Angiography on Safety and Efficacy for High-Power, Short-Duration Pulmonary Vein Isolation in Patients with Atrial Fibrillation
    Weyand, Sebastian
    Adam, Viola
    Beuter, Matthias
    Hanger, Simon
    Heinzmann, David
    Schrezenmeier, Willibald
    Seizer, Peter
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)