Optimizing intubation technique using a single-use video laryngoscope: A comparative study in a simulation model

被引:0
作者
Chen, Hui-Chin [1 ,2 ]
Liu, Jui-Fang [1 ,2 ]
Chi, Miao-Ching [1 ,2 ,3 ]
Cheng, Hsiu-Lan [1 ,4 ]
机构
[1] Chang Gung Univ Sci & Technol, Dept Resp Care, Puzi City 613, Chiayi County, Taiwan
[2] Chang Gung Univ Sci & Technol, Chron Dis & Hlth Promot Res Ctr, Puzi City, Taiwan
[3] Chiayi Chang Gung Mem Hosp, Div Pulm & Crit Care Med, Puzi City, Taiwan
[4] Natl Chung Cheng Univ, Dept Adult & Continuing Educ, Puzi City, Taiwan
关键词
conventional laryngoscope; COVID-19; intubation techniques; video laryngoscope; TRACHEAL INTUBATION; STYLET ANGULATION; DIFFICULT AIRWAY; MACINTOSH; TIME;
D O I
10.1097/MD.0000000000038946
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tracheal intubation poses a high risk of infection to medical staff due to Coronavirus disease 2019 (COVID-19) highly infectious nature. To mitigate this risk, various medical devices, including video laryngoscopy, have been developed to assist intubation. This study compared conventional laryngoscopy (Macintosh) and disposable video laryngoscopes (Medcaptain VS-10s and Honestmc Laryngoscope_LA10000) in terms of their use and operation processes. We designed a questionnaire to assess the operator perception of performing intubation with the devices, and statistical analysis was performed on 50 clinical staff members from 2 hospitals who had performed intubation or had learned intubation techniques. The primary outcomes were time to glottic visualization, intubation time, intubation success rate, distance between the operator and training model, and time from glottic visualization to tube insertion. The secondary outcomes were as follows: overall laryngoscope quality, operative feel, maneuverability, ease of use, and video quality. This study showed that video laryngoscopes were superior to conventional laryngoscopes in terms of quality, operative feel, and ease of use. When LA10000 was employed, the intubation success rate was higher, and the operator risk of infection was lower because of the greater distance from the training model. However, the use of video laryngoscopes requires appropriate education and training use of the devices. This study also demonstrated that when participants viewed a simple operation video prior to using video laryngoscopes, tube insertion time was shorter. Overall, video laryngoscopy can provide a safer and more convenient option for clinical medical personnel during pandemics.
引用
收藏
页数:6
相关论文
共 19 条
  • [1] Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway
    Aziz, Michael F.
    Dillman, Dawn
    Fu, Rongwei
    Brambrink, Ansgar M.
    [J]. ANESTHESIOLOGY, 2012, 116 (03) : 629 - 636
  • [2] Measurement of forces applied using a Macintosh direct laryngoscope compared with a Glidescope video laryngoscope in patients with predictors of difficult laryngoscopy A randomised controlled trial
    Cordovani, Daniel
    Russell, Twain
    Wee, Wallace
    Suen, Andrew
    Cooper, Richard M.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (03) : 221 - 226
  • [3] Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study
    Enomoto, Y.
    Asai, T.
    Arai, T.
    Kamishima, K.
    Okuda, Y.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) : 544 - 548
  • [4] Gómez-Ríos MA, 2024, REV ESP ANEST REANIM, V71, P171, DOI [10.1016/j.redare.2024.02.001, 10.1016/j.redar.2023.08.002]
  • [5] Videolaryngoscopy increases 'mouth-to-mouth' distance compared with direct laryngoscopy
    Hall, D.
    Steel, A.
    Heij, R.
    Eley, A.
    Young, P.
    [J]. ANAESTHESIA, 2020, 75 (06) : 822 - 823
  • [6] Henderson J., 2010, Miller's Anesthesia, V2, P1573
  • [7] Jones PM, 2007, CAN J ANAESTH, V54, P21, DOI 10.1007/BF03021895
  • [8] Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients
    Jungbauer, A.
    Schumann, M.
    Brunkhorst, V.
    Boergers, A.
    Groeben, H.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) : 546 - 550
  • [9] Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: a multicentre randomized controlled trial
    Kleine-Brueggeney, M.
    Greif, R.
    Schoettker, P.
    Savoldelli, G. L.
    Nabecker, S.
    Theiler, L. G.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (05) : 670 - 679
  • [10] Stylet angulation of 70 degrees reduces the time to intubation with the GlideScope®: A prospective randomised trial
    Lee, Yong-Cheol
    Lee, Jiwon
    Son, Je-Do
    Lee, Jae-Yoon
    Kim, Hyun-Chang
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (04) : 1428 - 1438