Effect of electrical discharge machining (EDM) bath composition on long-term corrosion of Ti-6Al-4V in simulated body fluid

被引:1
|
作者
Ahuir-Torres, J. I. [1 ]
Chadwick, J. [2 ]
West, G. [3 ]
Kotadia, H. R. [2 ,3 ]
Opoz, T. T. [1 ]
机构
[1] Liverpool John Moores Univ, Gen Engn Res Inst, Fac Engn & Technol, Sch Engn, Byrom St, Liverpool L3 3AF, England
[2] Liverpool John Moores Univ, Fac Engn & Technol, Sch Engn, Byrom St, Liverpool L3 3AF, England
[3] Univ Warwick, WMG, Coventry CV4 7AL, England
关键词
Ti-6Al-4V; Electrical discharge machining; Corrosion; Simulated body fluid; Electrochemical impedance spectroscopy; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; SURFACE MODIFICATION; TI6AL4V; BEHAVIOR; IMPLANT; POWDER; ALLOY; RESISTANCE; TI; POLARIZATION;
D O I
10.1016/j.electacta.2024.144865
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ti-6Al-4V (Ti64) alloy is a widely used bioimplant material due to its excellent properties. However, long-term exposure to body fluids can lead to corrosion, a concern given increasing lifespans. Electrical discharge machining (EDM) can improve Ti64 corrosion resistance at long term. This study investigates the long-term corrosion behaviour of Ti64 in simulated body fluid (SBF) after EDM treatment using different bath compositions (oil, water, and hydroxyapatite dissolution (HA)). Electrochemical and microscopy techniques were used to analyse corrosion mechanisms over immersion periods ranging from 2 h to 3 months. Results show that EDMtreated samples in water exhibited the highest corrosion resistance, while those processed in oil possessed the lowest. Especially, the corrosion resistance of samples treated in water and HA remained constant over time, unlike the non-EDMed and oil-treated samples. Furthermore, all samples exhibited evolving corrosion mechanisms over time, with faster deposition of SBF elements observed on oil and HA-treated samples, suggesting enhanced biointegration potential. The thicker deposited SBF layer on these samples further supports the potential of these EDM treatments to improve the biointegration of Ti64 implants.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of the electrical discharge machining on Ti6Al4V corrosion behaviour in simulated body fluid
    Ahuir-Torres, J. I.
    Kotadia, H. R.
    Opoz, T. T.
    SURFACE & COATINGS TECHNOLOGY, 2023, 470
  • [2] Corrosion of anodic TiO coatings on Ti-6Al-4V in simulated body fluid
    Narayanan, R.
    Seshadri, S. K.
    Kwon, Tae-Yub
    Kim, Kyo-Han
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 86A (02) : 502 - 509
  • [3] Effect of laser power on corrosion behavior of GO/Ti-6Al-4V coating in simulated body fluid solution
    Gong, Yuling
    Wu, Meiping
    Miao, Xiaojin
    Cui, Chen
    JOURNAL OF LASER APPLICATIONS, 2022, 34 (02)
  • [4] Fretting corrosion behaviour of Ti-6Al-4V/PMMA contact in simulated body fluid
    Mischler, S.
    Barril, S.
    Landolt, D.
    TRIBOLOGY-MATERIALS SURFACES & INTERFACES, 2009, 3 (01) : 16 - 23
  • [5] In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti-6Al-4V in simulated body fluid at 25 °C and 37 °C
    Alves, V. A.
    Reis, R. Q.
    Santos, I. C. B.
    Souza, D. G.
    Goncalves, T. de F.
    Pereira-da-Silva, M. A.
    Rossi, A.
    da Silva, L. A.
    CORROSION SCIENCE, 2009, 51 (10) : 2473 - 2482
  • [6] Surface integrity of Ti-6Al-4V alloy in hybrid electrical discharge machining processes
    Khosrozadeh, Behnam
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024, 238 (05) : 2258 - 2267
  • [7] Surface Finishing and Shape Effects on Corrosion Resistance of Ti-6Al-4V Alloy in the Simulated Body Fluid
    Souza, R. C.
    Maestro, C. A. R.
    Ribeiro Filho, S. L. M.
    Clemasco, S.
    Santos, B. A. F.
    Serenario, M. E. D.
    De Sousa Malafaia, A. M.
    Bastos, I. N.
    Brandao, L. C.
    Bueno, A. H. S.
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2022, 25
  • [8] Long-term corrosion performances and cytocompatibility of nitrided Ti and Ti-6Al-4V alloy in severe functional conditions
    Ion, R.
    Vasilescu, C.
    Drob, P.
    Vasilescu, E.
    Cimpean, A.
    Drob, S. I.
    Gordin, D. M.
    Gloriant, T.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2014, 65 (06): : 593 - 604
  • [9] Effect of replacement of V by Fe and Nb on passive film behavior of Ti-6Al-4V in simulated body fluid conditions
    Shukla, AK
    Balasubramaniam, R
    Bhargava, S
    JOURNAL OF ALLOYS AND COMPOUNDS, 2005, 389 (1-2) : 144 - 152
  • [10] Apatite formation on anodized Ti-6Al-4V alloy in simulated body fluid
    Cui, Xinyu
    Kim, Hyun-Min
    Kawashita, Masakazu
    Wang, Longbao
    Xiong, Tianying
    Kokubo, Tadashi
    Nakamura, Takashi
    METALS AND MATERIALS INTERNATIONAL, 2010, 16 (03) : 407 - 412