Highly Sensitive Sensor for the Determination of Riboflavin Using Thionine Coated Cadmium Selenide Quantum Dots Modified Graphite Electrode

被引:3
|
作者
Kalaivani, Arumugam [1 ]
Suresh Babu, Rajendran [2 ]
Sriman Narayanan, Sangilimuthu [3 ]
机构
[1] Saveetha Engn Coll, Dept Chem, Chennai 602105, Tamil Nadu, India
[2] Ctr Fed Educ Tecnol Celso Suckow Fonseca, Lab Expt & Appl Phys, Ave Maracana Campus 229, BR-20271110 Rio De Janeiro, Brazil
[3] Univ Madras, Sch Chem Sci, Dept Analyt Chem, Guindy Campus, Chennai 600025, Tamil Nadu, India
来源
MICRO-SWITZERLAND | 2023年 / 3卷 / 03期
关键词
amperometry; CdSe QDs; cyclic voltammetry; modified electrode; riboflavin; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL-BEHAVIOR; GOLD NANOPARTICLES; FLUORESCENCE; FILM; FABRICATION; REDUCTION; BIOSENSOR; SAMPLES;
D O I
10.3390/micro3030048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the electrochemical non-enzymatic detection of Riboflavin (RF) was proposed based on its catalytic reduction in a Thionine-coated Cadmium Selenide Quantum dots (TH@CdSe QDs)-modified paraffin wax-impregnated graphite electrode (PIGE) that was prepared using a novel approach. The synthesized TH@CdSe QDs were confirmed by UV-Vis spectroscopy, Confocal Raman Microscopy and High Resolution Transmission Electron Microscopy (HRTEM) studies. The electrochemical response of the TH@CdSe QDs-modified PIGE was studied by cyclic voltammetry. The voltammetric response of RF at the TH@CdSe QDs-modified PIGE showed higher current than the bare PIGE. Under optimum conditions, the electrocatalytic reduction currents of RF was found to be linearly related to its concentration over the range of 1.6 x 10-7 M to 1.4 x 10-4 M with a detection limit of 53 x 10-9 M (S/N = 3). The TH@CdSe QDs-modified PIGE was utilized as an amperometric sensor for the detection of RF in flow systems was performed by carrying out hydrodynamic and chronoamperometric experiments. The TH@CdSe QDs-modified PIGE showed very good stability and a longer shelf life. The applicability of the fabricated electrode was justified by the quantification of RF in commercial tablets.
引用
收藏
页码:686 / 698
页数:13
相关论文
共 50 条
  • [1] A Highly Sensitive Dopamine Sensor Based on Graphene Quantum Dots Modified Glassy Carbon Electrode
    Zheng, Shengbiao
    Huang, Rong
    Ma, Xiaoqing
    Tang, Jing
    Li, Zirong
    Wang, Xuchuan
    Wei, Jumeng
    Wang, Jianfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (06): : 5723 - 5735
  • [2] Highly Sensitive Determination of Theophylline Based on Graphene Quantum Dots Modified Electrode
    Ganjali, Mohammad Reza
    Dourandish, Zahra
    Beitollahi, Hadi
    Tajik, Somayeh
    Hajiaghababaei, Leila
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (03): : 2448 - 2461
  • [3] Polymer Modified Carbon Paste Electrode as a Sensitive Sensor for the Electrochemical Determination of Riboflavin and Its Application in Pharmaceutical and Biological Samples
    D'Souza, Edwin S.
    Manjunatha, J. G.
    Raril, C.
    Tigari, Girish
    Pushpanjali, P. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 461 - 472
  • [4] Determination of Epinephrine using a Novel Sensitive Electrochemiluminescence Sensor based on ZnO Nanoparticles Modified Pencil Graphite Electrode
    Zheng, Ruijuan
    Zhao, Chenhao
    Zhong, Jianhai
    Qiu, Zehai
    Hu, Zhibiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9380 - 9390
  • [5] Sensitive electrochemical determination of riboflavin at simple and low-cost poly (valine) modified graphite paste electrode
    Kamath, K. Abhayashri
    Manjunatha, J. G.
    Girish, T.
    Sillanpaa, Mika
    Ammar, M.
    Albaqami, Munirah D.
    INORGANIC CHEMISTRY COMMUNICATIONS, 2022, 143
  • [6] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [7] Highly sensitive electrochemical determination of azathioprine using a glassy carbon electrode modified with Au neuronal-like nanostructures
    Mei, Li-Ping
    Feng, Jiu-Ju
    Huang, Su-Su
    Shi, Ya-Cheng
    Wang, Ai-Jun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 996 - 1002
  • [8] Highly sensitive and simultaneous electrochemical determination of lead and cadmium ions by poly(thionine)/MWCNTs-modified glassy carbon electrode in the presence of bismuth ions
    Seifi, Afsaneh
    Afkhami, Abbas
    Madrakian, Tayyebeh
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (10) : 1513 - 1523
  • [9] Fabrication of Poly (Evans blue) Modified Graphite Paste Electrode as an Electrochemical Sensor for Sensitive and Instant Riboflavin Detection
    Charithra, M. M.
    Manjunatha, J. G.
    MOROCCAN JOURNAL OF CHEMISTRY, 2021, 9 (01): : 7 - 17
  • [10] A bimetallic nanoparticle/graphene oxide/thionine composite-modified glassy carbon electrode used as a facile ratiometric electrochemical sensor for sensitive uric acid determination
    Gao, Xiaohui
    Gui, Rijun
    Xu, Kendrick Qizhou
    Guo, Huijun
    Jin, Hui
    Wang, Zonghua
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (18) : 14796 - 14804