Fabrication of nanomolecular platform based immunosensor for non-invasive electrochemical detection of oral cancer: An in vitro study

被引:1
|
作者
Choudhary, Meenakshi [1 ,2 ,3 ]
Kumar, Vinay [4 ]
Parambath, Ashik Babu [5 ]
Caplash, Shruti [3 ]
Yadav, Birendra Kumar [6 ,7 ]
Kaur, Satbir [3 ]
Shah, Sapna Ratan [5 ]
Arora, Kavita [1 ,5 ]
机构
[1] Jawaharlal Nehru Univ JNU, Adv Instrumentat Res Facil, New Delhi 110067, India
[2] Indian Inst Technol Delhi IITD, Ctr Biomed Engn, New Delhi 110016, India
[3] Punjabi Univ Patiala, Dept Human Genet, Patiala 147002, Punjab, India
[4] Penn State Univ, Hershey Med Ctr, 500 Univ Dr, Hershey, PA 17033 USA
[5] Jawaharlal Nehru Univ JNU, Sch Computat & Integrat Sci, New Delhi 110067, India
[6] Bio Bank India Fdn BBIF, Virtual Biobank, New Delhi, India
[7] Inst Liver & Billiary Sci ILBS, Natl Liver Dis Biobank, New Delhi, India
来源
TALANTA OPEN | 2024年 / 10卷
关键词
Oral cancer; Immunosensor; S100; Silver nanoparticles; Chitosan; Metal-organic frameworks; Point-of-care diagnosis; DIAGNOSIS;
D O I
10.1016/j.talo.2024.100352
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver nanoparticles (AgNPs)-Chitosan (Chi) functionalized cysteine (cys)-SAM (self-assembled monolayer) based electrochemical, label free, ultrasensitive, non-invasive immunosensing nanomolecular platform has been fabricated for the detection of novel OC biomarker S-100. This has been achieved through bio-functionalization of AgNPs-Chi/cys/mini gold slides by covalent immobilization of anti-S100 antibodies. Cyclic voltammetric (CV) studies establish successful fabrication of anti-S100/AgNPs-Chi/Au nanomolecular platform. Differential pulse voltammetric (DPV) measurements reveal that anti-S100/Chi-AgNPs/Au is able to sense 50 fg mL(-1 )- 500 ng mL(-1) of S100 in buffer and in spiked saliva samples within 120 s interaction time having improved favorable shelf life and specificity. The fabricated platform is very selective and able to detect S100 in OC patient/s saliva samples warrants realization of simple non-invasive electrochemical immunosensor for in situ or on-site applications (especially for remote areas) for early diagnosis of OC while offering bio-compatibility at low cost.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Highly sensitive and non-invasive electrochemical immunosensor for salivary cortisol detection
    Dhull, Nidhi
    Kaur, Gurpreet
    Gupta, Vinay
    Tomar, Monika
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 293 : 281 - 288
  • [2] MoS2-ZnO Nanocomposite Mediated Immunosensor for Non-Invasive Electrochemical Detection of IL8 Oral Tumor Biomarker
    Vetrivel, Cittrarasu
    Sivarasan, Ganesan
    Durairaj, Kaliannan
    Ragavendran, Chinnasamy
    Kamaraj, Chinnaperumal
    Karthika, Sankar
    Lo, Huang-Mu
    DIAGNOSTICS, 2023, 13 (08)
  • [3] Nanostructured titania based electrochemical impedimetric biosensor for non-invasive cancer detection
    Kumar, Sumit
    Kumar, Jitendra
    Sharma, Shailesh Narayan
    MATERIALS RESEARCH EXPRESS, 2018, 5 (12):
  • [4] Nanostructured zirconia decorated reduced graphene oxide based efficient biosensing platform for non-invasive oral cancer detection
    Kumar, Suveen
    Sharma, Jai Gopal
    Maji, Sagar
    Malhotra, Bansi Dhar
    BIOSENSORS & BIOELECTRONICS, 2016, 78 : 497 - 504
  • [5] Highly sensitive protein functionalized nanostructured hafnium oxide based biosensing platform for non-invasive oral cancer detection
    Kumar, Suveen
    Kumar, Saurabh
    Tiwari, Sachchidanand
    Augustine, Shine
    Srivastava, Saurabh
    Yadav, Birendra Kumar
    Malhotra, Bansi Dhar
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 : 1 - 10
  • [6] Silver molybdate nanoparticles based immunosensor for the non-invasive detection of Interleukin-8 biomarker
    Pachauri, Namrata
    Lakshmi, G. B. V. S.
    Sri, Smriti
    Gupta, Pramod K.
    Solanki, Pratima R.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 113
  • [7] The role of nanoparticles in non-invasive electrochemical immunosensor technology and recent developments
    Sanko, Vildan
    Erkmen, Cem
    Kuralay, Filiz
    ELECTROANALYSIS, 2024, 36 (06)
  • [8] Non-invasive urine based tests for the detection of bladder cancer
    Wadhwa, Neha
    Jatawa, Suresh Kumar
    Tiwari, Archana
    POSTGRADUATE MEDICAL JOURNAL, 2013, 89 (1052) : 352 - 357
  • [9] Non-invasive urine based tests for the detection of bladder cancer
    Wadhwa, Neha
    Jatawa, Suresh Kumar
    Tiwari, Archana
    JOURNAL OF CLINICAL PATHOLOGY, 2012, 65 (11) : 970 - 975
  • [10] L-cysteine capped lanthanum hydroxide nanostructures for non-invasive detection of oral cancer biomarker
    Tiwari, Sachchidanand
    Gupta, Pramod K.
    Bagbi, Yana
    Sarkar, Tamal
    Solanki, Pratima R.
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 1042 - 1052