A novel dual-band defected ground structure wearable microstrip patch antenna for breast tumor detection in biomedical applications

被引:0
作者
Gour, Sonam [1 ,2 ]
Rathi, Amit [1 ]
Rawal, Pallav [3 ]
机构
[1] Manipal Univ Jaipur, Dept Elect & Commun Engn, Jaipur 303007, Rajasthan, India
[2] Poornima Coll Engn, Dept Elect & Commun Engn, Jaipur, Rajasthan, India
[3] Swami Keshvanand Inst Technol Management & Gramoth, Dept EC Engn, Jaipur, Rajasthan, India
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 03期
关键词
defected ground structure; dual band design; microstrip patch antenna; resonance frequency; DESIGN; COMPACT; SYSTEM; MODULE;
D O I
10.1088/2631-8695/ad766a
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a dual-band, low-profile wearable antenna for detecting breast tumors in biomedical applications. The antenna is designed on the FR4 substrate with an optimized dimension of 32 x 27.5 x 0.61 mm3. The compact rectangular patch is miniaturized by cutting the rectangular slots on the front side. The partial ground structure is used for moving the resonance frequency in the ISM band region and for giving the tripping result of the return loss. A breast phantom is created between the transmitter and receiver for detecting the tumor in the phantom model. The different sizes and positions of the tumor in the breast phantom provide different values of the return loss. The final optimized design of the antenna is operated at 2.43 GHz and 3.32 GHz with -35 and -24 return losses respectively. It has been observed from the simulated and measured results that the antenna has a negligible difference between the reflected coefficient, radiation pattern and gain. Afterward, the antenna is also checked for biocompatibility, which represents its good performance. The on-body analysis of the antenna represents a minor variation in the results. The Specific Absorption Ratio (SAR) value of the antenna is in the acceptable range as defined for the wearable device. It is a promising compact wearable antenna that can be used in biomedical applications.
引用
收藏
页数:11
相关论文
共 61 条
  • [21] Gour S., 2022, INT C COMM DEV NETW, P235
  • [22] Gour S., 2022, INT C INT COMP COMM, P21
  • [23] Fast 3-D Tomographic Microwave Imaging for Breast Cancer Detection
    Grzegorczyk, Tomasz M.
    Meaney, Paul M.
    Kaufman, Peter A.
    diFlorio-Alexander, Roberta M.
    Paulsen, Keith D.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) : 1584 - 1592
  • [24] Three-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: Design of an antenna-array element
    Hagness, SC
    Taflove, A
    Bridges, JE
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1999, 47 (05) : 783 - 791
  • [25] IEEE-C95, 2006, C9512005 IEEE, P1, DOI [10.1109/IEEESTD.2006.99501, DOI 10.1109/IEEESTD.2006.99501]
  • [26] Design and Analysis of Dual Polarized Broadband Microstrip Patch Antenna for 5G mmWave Antenna Module on FR4 Substrate
    Kim, Gyoungdeuk
    Kim, Sangkil
    [J]. IEEE ACCESS, 2021, 9 : 64306 - 64316
  • [27] A Review of Implantable Patch Antennas for Biomedical Telemetry: Challenges and Solutions
    Kiourti, Asimina
    Nikita, Konstantina S.
    [J]. IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2012, 54 (03) : 210 - 228
  • [28] Klemm M., 2004, Conference Proceedings. 7th European Conference on Wireless Technology (IEEE Cat. No.04EX964), P285
  • [29] Patch-antenna miniaturization using recently available ceramic substrates
    Kula, J. S.
    Psychoudakis, D.
    Liao, W-J.
    Chen, C-C.
    Volakis, J. L.
    Halloran, J. W.
    [J]. IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2006, 48 (06) : 13 - 20
  • [30] Capacitively Loaded Circularly Polarized Implantable Patch Antenna for ISM Band Biomedical Applications
    Liu, Changrong
    Guo, Yong-Xin
    Xiao, Shaoqiu