Anterior segment optical coherence tomography for the detection of silicone oil emulsification on the iris surface

被引:0
作者
Karsten, Mona [1 ]
Morello, Matteo [2 ]
Lau, Imke [1 ]
Druchkiv, Vasyl [1 ]
Lopes, Ines Valente [1 ]
Dulz, Simon [1 ]
Skevas, Christos [1 ]
Spitzer, Martin Stephan [1 ]
Mautone, Luca [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Ophthalmol, Hamburg, Germany
[2] Univ Brescia, Cardiol Sch, Brescia, Italy
关键词
ULTRASOUND BIOMICROSCOPY; INTRAOCULAR-PRESSURE; CHAMBER; VITRECTOMY;
D O I
10.1038/s41433-024-03261-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo investigate the presence of silicone oil (SO)-emulsification on the anterior iris surface with anterior segment optical coherence tomography (AS-OCT).MethodsIn this single-center cross-sectional study, vitrectomized eyes with SO tamponade that underwent AS-OCT imaging and gonioscopy examination during the postoperative follow-up visits, were reviewed.Results45 eyes of 42 consecutive patients were included. In 35.6% of the eyes (n = 16) emulsified SO droplets were detected in the anterior chamber (AC) angle by gonioscopy and in 55.6% (n = 25) on the anterior iris surface by AS-OCT imaging. The presence of SO emulsifications in the AC-angle correlated with the presence of SO emulsifications on the anterior iris surface (OR = 13.4, 95% CI [2.179-82.130]; p = 0.005). The accuracy of the AS-OCT predicting the presence of SO in the AC-angle was 71.0% and the sensitivity was 87.5%. No significant association between SO droplets in the AC and other clinical parameters including endotamponade-duration or type of silicone oil were found. The presence of emulsified SO droplets on the anterior iris surface detected by AS-OCT was significantly correlated to postoperative IOP rise (p = 0.027).ConclusionAS-OCT is a suitable method for the detection of SO on the anterior iris surface. SO droplets on the iris surface correlate with elevated postoperative IOP and with the presence of SO in the AC detected by gonioscopy, therefore AS-OCT might be used as a screening method for the detection of SO migration into the AC.Trial registration numberInstitutional Review Board of the Hamburg Medical Chamber (Ethik-Kommission der & Auml;rztekammer Hamburg): 2023-300372-WF.
引用
收藏
页码:3175 / 3179
页数:5
相关论文
共 32 条
[1]   Characteristics, fates and complications of long-term silicone oil tamponade after pars plana vitrectomy [J].
Abu-Yaghi, Nakhleh E. ;
Abu Gharbieh, Yazan A. ;
Al-Amer, Ahmad M. ;
AlRyalat, Saif Aldeen S. ;
Nawaiseh, Mohammed B. ;
Darweesh, Mohammad J. ;
Alkukhun, Leen R. ;
Abed, Alaa M. ;
Saleh, Omar A. ;
Ababneh, Osama H. .
BMC OPHTHALMOLOGY, 2020, 20 (01)
[2]  
Al-Habsi Shihab Hilal, 2023, Oman J Ophthalmol, V16, P110, DOI 10.4103/ojo.ojo_92_22
[3]   Correlation between quantity of silicone oil emulsified in the anterior chamber and high pressure in vitrectomized eyes [J].
Avitabile, T ;
Bonfiglio, V ;
Cicero, A ;
Torrisi, B ;
Reibaldi, A .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (04) :443-448
[4]  
Azzolini C, 1995, INT OPHTHALMOL, V19, P191
[5]  
BARR CC, 1993, OPHTHALMOLOGY, V100, P1629
[6]  
Baskaran Prabu, 2020, Oman J Ophthalmol, V13, P173, DOI 10.4103/ojo.OJO_196_2019
[7]   Intraocular pressure changes during and after silicone oil endotamponade (Review) [J].
Branisteanu, Daniel Constantin ;
Moraru, Andreea Dana ;
Maranduca, Minela Aida ;
Branisteanu, Daciana Elena ;
Stoleriu, Gabriela ;
Branisteanu, Catalina Ioana ;
Balta, Florian .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (06)
[8]  
BROURMAN ND, 1989, OPHTHALMOLOGY, V96, P759
[9]   Evaluation of anterior segment parameters using pentacam in silicone oil-injected patients after pars plana vitrectomy [J].
Calik, Burcu ;
Ozturk, Muzaffer ;
Serdarogullari, Huseyin ;
Elcioglu, Mustafa .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (11) :621-625
[10]   In vitro emulsification assessment of new silicone oils [J].
Caramoy, Albert ;
Schroeder, Sabine ;
Fauser, Sascha ;
Kirchhof, Bernd .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (04) :509-512