A hemodynamic study of blood flow models on various stent graft configurations during aorto-iliac reconstruction

被引:1
|
作者
Tzirakis, Konstantinos [1 ]
Kontopodis, Nikolaos [2 ]
Ioannou, Christos V. [2 ]
机构
[1] Hellen Mediterranean Univ, Sch Engn, Mech Engn Dept, Iraklion 71410, Greece
[2] Univ Crete, Sch Med, Vasc Surg Dept, Iraklion, Greece
关键词
Non-Newtonian blood flow; idealized stent graft; computational fluid dynamics; finite volume method; hemodynamic; parameters; ABDOMINAL AORTIC-ANEURYSM; WALL SHEAR-STRESS; ENDOGRAFT CONFIGURATION; ENDOVASCULAR REPAIR; DISPLACEMENT FORCE; SURGICAL REPAIR; NECK ANGULATION; METAANALYSIS; BIFURCATION; MIGRATION;
D O I
10.3233/CH-232058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: To compare the hemodynamic performance of three (Bottom Up non-ballet, Top-Down non-ballet, Top Down ballet) idealized stent graft configurations used during endovascular repair of abdominal aortic aneurysms, under the influence of various rheological models. METHODS: Ten rheological models are assumed and a commercial finite volume solver is employed for the simulation of blood flow under realistic boundary conditions. An appropriate mesh convergence study is performed and five hemodynamic variables are computed: the time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), endothelial cell activation potential (ECAP) and displacement force (DF) for all three configurations. RESULTS: The choice of blood flow model may affect results, but does not constitute a significant determinant on the overall performance of the assumed stent grafts. On the contrary, stent graft geometry has a major effect. Specifically, the Bottom Up non-ballet type is characterized by the least favorable performance presenting the lowest TAWSS and the highest OSI, RRT and ECAP values. On the other hand, the Top Down ballet type presents hemodynamic advantages yielding the highest TAWSS and lowest OSI, RRT and ECAP average values. Furthermore, the ballet type is characterized by the lowest DF, although differences observed are small and their clinical relevance uncertain. CONCLUSIONS: The effect of the assumed rheological model on the overall performance of the grafts is not significant. It is thus relatively safe to claim that it is the type of stent graft that determines its overall performance rather than the adopted blood flow model.
引用
收藏
页码:199 / 219
页数:21
相关论文
共 14 条
  • [1] Selection of Bifurcated Grafts' Dimensions during Aorto-Iliac Vascular Reconstruction Based on Their Hemodynamic Performance
    Tzirakis, Konstantinos
    Kamarianakis, Yiannis
    Kontopodis, Nikolaos
    Ioannou, Christos V.
    BIOENGINEERING-BASEL, 2023, 10 (07):
  • [2] Endovascular Stent Graft Repair for Mycotic Aorto-Iliac Aneurysm Due to Brucella
    Jiang, Jianjun
    Shao, Wenchong
    Shen, Shuohao
    Li, Guangzhen
    Liu, Yang
    Ding, Xiangjiu
    Su, Qingbo
    JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (06) : 1098 - 1106
  • [3] Blood flow velocity prediction in aorto-iliac stent grafts using computational fluid dynamics and Taguchi method
    Chong, Albert Y.
    Doyle, Barry J.
    Jansen, Shirley
    Ponoshi, Stefan
    Cisonni, Julien
    Sun, Zhonghua
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 84 : 235 - 246
  • [4] Numerical study of blood flow in an anatomically realistic aorto-iliac bifurcation generated from MRI data
    Long, Q
    Xu, XY
    Bourne, M
    Griffith, TM
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (04) : 565 - 576
  • [5] Aorto-Iliac Stent Graft Infection Complicated by Endotension and Consequent Rupture of the Aneurysmal Sac: a Case Report
    Van den Eynde, W.
    van Riel, W.
    Nevelsteen, A.
    Daenen, G.
    ACTA CHIRURGICA BELGICA, 2011, 111 (04) : 246 - 249
  • [6] Novel-Designed Iliac Branch Stent Graft for Internal Iliac Artery Reconstruction during Aneurysm Repair
    Zhang, Tao
    Guo, Wei
    Ma, Xiaohui
    Jia, Xin
    Liu, Xiaoping
    Dong, Yanfen
    Xiong, Jiang
    Jia, Senhao
    ANNALS OF VASCULAR SURGERY, 2015, 29 (02) : 189 - 196
  • [7] Prevention of Buttock Claudication by Preserving Antegrade Bilateral Superior Gluteal Arterial Blood Flow in EVAR for Aorto-Iliac Aneurysm Accompanied by Bilateral Internal Iliac Artery Aneurysms
    Tajima, Yuta
    Goto, Hitoshi
    Akamatsu, Daijiro
    Serizawa, Fukashi
    Suzuki, Shunya
    Horii, Shinichiro
    Ogasawara, Norinobu
    Takahashi, Hirokazu
    Nagaoka, Yohei
    Kamei, Takashi
    ANNALS OF VASCULAR DISEASES, 2022, 15 (01) : 53 - 57
  • [8] Hemodynamic variations due to spiral blood flow through four patient-specific bifurcated stent graft configurations for the treatment of abdominal aortic aneurysms
    Stefanov, Florian
    McGloughlin, Tim
    Delassus, Patrick
    Morris, Liam
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (02) : 179 - 196
  • [9] Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
    Yeow, Siang Lin
    Leo, Hwa Liang
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [10] Influence of Iliac Stenotic Lesions on Blood Flow Patterns Near a Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Stent Configuration
    Jebbink, Erik Groot
    Engelhard, Stefan
    Lajoinie, Guillaume
    de Vries, Jean-Paul P. M.
    Versluis, Michel
    Reijnen, Michel M. P. J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (06) : 800 - 808