Comparison of forearm and intra-arterial blood pressure measurements according to body and arm positions in obese patients

被引:0
|
作者
Ismailoglu, Elif Gunay [1 ]
Aygun, Hakan [2 ]
Sahan, Seda [1 ]
Ergin, Eda [1 ]
Gectan, Eliz [3 ]
机构
[1] Izmir Bakircay Univ, Nursing Dept, Hlth Sci Fac, Izmir, Turkiye
[2] Izmir Bakircay Univ, Med Fac, Dept Anesthesiol, Izmir, Turkiye
[3] Izmir Bakircay Univ Cigli Training & Res Hosp, Dept Anesthesiol, Izmir, Turkiye
关键词
blood pressure; forearm blood pressure; intensive care; obese patients; upper arm blood pressure; MANAGEMENT; READINGS; CUFF;
D O I
10.1111/jep.14093
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
RationaleNoninvasive blood pressure (BP) monitoring is very important also difficult for accurate diagnosis and monitor of obese patients.AimsThe study aimed to assess the agreement between forearm arm BP and intra-arterial BP values in a different body and arm positions in obese patients.MethodsThe descriptive study was carried out on 60 intensive care patients with a body mass index above 30 kg/m2 who were monitored with invasive radial BP in the general and surgical intensive care units. BP values obtained from the upper arm and forearm with different arm and body positions were compared with intra-arterial BP results. Bland-Altman analysis and correlation coefficient were used for the accuracy of upper and forearm noninvasive BP reading in different positions.ResultsThe best agreement was found between the forearm systolic BP in the supine and half-sitting position with the arm down and intra-arterial BP values. Also, the best agreement in diastolic BP was found between the half-sitting and half-sitting position with the arm down and intra-arterial BP.ConclusionsForearm systolic BP measurement, especially in the supine and half-sitting position with the arm below the heart level position, was best agreement with intra-arterial measurement, regarded as the gold standard. For this reason, it is more appropriate to use forearm BP measurement in obese patients monitored in intensive care to obtain accurate results.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The accuracy of radial artery applanation tonometry and intra-arterial blood pressure monitoring in critically ill patients: An evidence-based review
    Borg, Amber Leigh
    Trapani, Josef
    NURSING IN CRITICAL CARE, 2024, 29 (06) : 1751 - 1757
  • [32] Influence of Left Ventricular Morphology and Functions in The Accuracy of Non-Invasive Blood Pressure NIBP Recording Compared to Intra-Arterial Pressure IAP - A Correlative Study
    Sobana, R.
    Ganesh, Amrita
    Jaiganesh, K.
    Parthasarathy, S.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 : L34 - L40
  • [33] Agreement between noninvasive oscillometric and invasive intra-arterial blood pressure in children with ruptured brain arteriovenous malformations
    Chang, Nathan
    Poon, Diana
    Casazza, May
    Medrano, Amanda
    Basnett, Kaitlyn
    Koilparampil, Lesley
    Rasmussen, Lindsey
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2024, 243
  • [34] Timeline of blood pressure changes after intra-arterial therapy for acute ischemic stroke based on recanalization status
    John, Seby
    Hazaa, Walaa
    Uchino, Ken
    Hussain, Muhammad S.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (05) : 455 - 458
  • [35] Intra-arterial blood pressure and heart rate reactivity to behavioral stress in normotensive, borderline, and mild hypertensive men
    Tuomisto, MT
    HEALTH PSYCHOLOGY, 1997, 16 (06) : 554 - 565
  • [36] Continuous Non-Invasive Arterial Pressure Monitoring (ClearSight System) and Ankle Blood Pressure Measurements as Alternatives to Conventional Arm Blood Pressure
    Lee, Seohee
    Chung, Jaeyeon
    Bae, Jinyoung
    Cho, Youn Joung
    Nam, Karam
    Jeon, Yunseok
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 11
  • [37] Comparison between Continuous Ambulatory Arterial Blood Pressure Monitoring and Standard Blood Pressure Measurements among Patients of Younger and Older Age Group
    Babic, Betty Korljan
    Bagatin, Jugoslav
    Kokic, Slaven
    Ostojic, Sanja Barsic
    Carevic, Vedran
    Berovic, Nina
    COLLEGIUM ANTROPOLOGICUM, 2009, 33 (01) : 65 - 70
  • [38] Patterns of intra-arterial blood pressure monitoring for patients undergoing total shoulder arthroplasty under general anesthesia: a retrospective analysis of 23,073 patients
    Gabriel, Rodney A.
    Beverly, Anair
    Dutton, Richard P.
    Urman, Richard D.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 877 - 884
  • [39] Comparison of ambulatory blood pressure measurement with home, office and pharmacy measurements: is arterial blood pressure measured at pharmacy reliable?
    Mutlu, Sinan
    Sari, Oktay
    Arslan, Erol
    Aydogan, Umit
    Doganer, Yusuf C.
    Koc, Bayram
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2016, 22 (01) : 40 - 45
  • [40] Increased ambulatory arterial stiffness index and blood pressure load in normotensive obese patients
    Efe, Fatma Kaplan
    Tek, Mujgan
    AFRICAN HEALTH SCIENCES, 2021, 21 (03) : 1185 - 1190