A rotating beam-blocker method for cone beam CT scatter correction

被引:0
|
作者
Cui, Hehe [1 ,2 ,3 ,4 ]
Zhan, Haolin [1 ]
Yuan, Xiaogang [1 ]
Yang, Yidong [1 ,5 ,6 ]
机构
[1] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei, Anhui, Peoples R China
[2] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Canc Ctr, Wuhan, Peoples R China
[3] Huazhong Univ Sci & Technol, Union Hosp, Inst Radiat Oncol, Tongji Med Coll, Wuhan, Peoples R China
[4] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Hubei Key Lab Precis Radiat Oncol, Wuhan, Peoples R China
[5] Univ Sci & Technol China, Affiliated Hosp 1, Dept Radiat Oncol, Div Life Sci & Med,USTC, Hefei, Anhui, Peoples R China
[6] Univ Sci & Technol China, Ion Med Res Inst, Hefei, Anhui, Peoples R China
关键词
beam-blocker; cone beam CT; scatter correction; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION; GEOMETRY; DESIGN;
D O I
10.1002/mp.17274
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundCone beam CT (CBCT) is widely utilized in clinics. However, the scatter artifact degrades the CBCT image quality, hampering the expansion of CBCT applications. Recently, beam-blocker methods have been used for CBCT scatter correction and proved their high cost-effectiveness. PurposeA rotating beam-blocker (RBB) method for CBCT scatter correction was proposed to complete scatter correction and image reconstruction within a single scan in both full- and half-fan scan scenarios. MethodsThe RBB consisted of two open regions and two blocked regions, and was designed as a centrosymmetric structure. The open and blocked projections could be alternatively obtained within one single rotation. The open projections were corrected with the scatter signal calculated from the blocked projections, and then used to reconstruct the 3D image via the Feldkamp-Davis-Kress algorithm. The performance of the RBB method was evaluated on head and pelvis phantoms in scenarios with and without a bowtie filter. The images obtained from nine repeated scans in each scenario were used to calculate the evaluation metrics including the CT number error, spatial nonuniformity (SNU) and contrast-to-noise ratio (CNR). ResultsFor the head phantom, the CT number error was decreased to <5 after scatter correction from >200 HU before correction when scanned without a bowtie filter, and to <4 from >160 HU when scanned with a full bowtie filter. For the pelvis phantom, the CT number error was reduced to <12 after scatter correction from >250 HU before correction when scanned without a bowtie filter, and to <10 from >190 HU when scanned with a half bowtie filter. After scatter correction, the uniformity and contrast were both improved, resulting in an SNU of >79% decrease and CNR of >2 times increase, respectively. ConclusionsHigh-quality CBCT images could be obtained in a single scan after using the proposed RBB method for scatter correction, enabling more accurate image guidance for surgery and radiation therapy applications. With almost no time delay between the successive open and blocked projections, the RBB method could eliminate the motion-induced anatomical mismatches between the corresponding open and blocked projections and could find particular usefulness in thoracic and abdominal imaging.
引用
收藏
页码:7320 / 7331
页数:12
相关论文
共 50 条
  • [31] Optimization of a Moving Blocker System for Cone-Beam Computed Tomography Scatter Correction
    Ouyang, L.
    Yan, H.
    Zhang, H.
    Jia, X.
    Jiang, S.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 125 - 125
  • [32] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    Chinese Physics B, 2014, 23 (09) : 519 - 525
  • [33] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [34] A new X-ray scatter correction method based on BAG for cone beam CT
    Geng, Ping
    Teng, Fei
    Xiao, Dayu
    Kang, Yan
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 326 - 329
  • [35] Scatter correction method for cone-beam CT based on interlacing-slit scan
    Huang Kui-Dong
    Zhang Hua
    Shi Yi-Kai
    Zhang Liang
    Xu Zhe
    CHINESE PHYSICS B, 2014, 23 (09)
  • [36] A unified scatter rejection and correction method for cone beam computed tomography
    Altunbas, Cem
    Park, Yeonok
    Yu, Zhelin
    Gopal, Anant
    MEDICAL PHYSICS, 2021, 48 (03) : 1211 - 1225
  • [37] A Novel Scatter Correction Method for Cone-Beam Computed Tomography
    Zhou, Kun
    Tian, Jian
    Meng, Xiangxi
    Yang, Kun
    Xu, Baixuan
    Yang, Zhi
    Ren, Qiushi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) : 632 - 638
  • [38] A Rotating Blocker for Random-Ray Under-Sampling Cone Beam CT for Simultaneously Dose Reduction and Scatter Correction: A Proof-Of-Concept Study
    Xu, Y.
    Li, B.
    Shen, C.
    Male, J.
    Zhou, L.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E130 - E130
  • [39] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [40] The Effect of Off-Focus Radiation in Scatter Correction for Cone Beam CT
    Shi, L.
    Zhu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E459 - E459