Application of a Novel UPLC-MS/MS Method for Analysis of Rivaroxaban Concentrations in Dried Blood Spot and Plasma Samples Collected from Patients with Venous Thrombosis

被引:0
|
作者
Pawlak, Kornel [1 ,2 ]
Kruszyna, Lukasz [3 ]
Miecznikowska, Marta [1 ]
Karazniewicz-Lada, Marta [1 ]
机构
[1] Poznan Univ Med Sci, Dept Phys Pharm & Pharmacokinet, Rokietnicka 3, PL-60806 Poznan, Poland
[2] Poznan Univ Med Sci, Doctoral Sch, PL-60812 Poznan, Poland
[3] Poznan Univ Med Sci, Dept Vasc & Endovascular Surg Angiol & Phlebol, Dluga St 1-2, PL-61848 Poznan, Poland
来源
MOLECULES | 2024年 / 29卷 / 17期
关键词
UPLC-MS/MS; rivaroxaban; plasma; DBS; venous thrombosis; DIRECT ORAL ANTICOAGULANTS; WHOLE-BLOOD; QUANTIFICATION;
D O I
10.3390/molecules29174140
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Despite a higher safety profile compared to vitamin K antagonists, rivaroxaban therapy is still connected with multiple adverse effects, such as a high risk of bleeding. Thus, therapeutic drug monitoring (TDM) of rivaroxaban concentrations is suggested. An alternative to plasma samples can be dried blood spots (DBS), which minimize the cost of sample storage and transport. In this study, we developed a UPLC-MS/MS method for the analysis of rivaroxaban in DBS and plasma samples. Chromatographic separation was achieved on a Zorbax Eclipse Plus C18 column (2.1 x 100 mm; 3.5 mu m, Agilent Technologies Inc., Santa Clara, CA, USA) with a mobile phase consisting of water and acetonitrile, both containing 0.1% formic acid. The analytes were detected using a positive ionization mode by multiple reaction monitoring. We validated the method according to ICH guidelines. The precision and accuracy were satisfactory. Extraction recovery was approximately 57% and 66% for DBS and plasma samples, respectively. A high correlation between rivaroxaban concentrations in plasma and DBS samples collected from patients was confirmed with Deming regression. The suitability of both sampling techniques for the rivaroxaban TDM was also verified by Bland-Altman plots based on DBS-predicted and observed plasma concentrations. In addition, we found a significant relationship between rivaroxaban concentrations and coagulation parameters, including prothrombin time (PT) and international normalized ratio (INR).
引用
收藏
页数:17
相关论文
共 42 条
  • [1] Development, validation, and application of an UPLC-MS/MS method for norvancomycin analysis in human blood plasma
    Mei, Shenghui
    Wang, Jiaqing
    Cheng, Qing
    Zhu, Leting
    Yang, Li
    Chen, Ruiling
    Zhao, Zhigang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1072 : 199 - 204
  • [2] Novel determination of sofosbuvir and velpatasvir in human plasma by UPLC-MS/MS method: Application to a bioequivalence study
    Rezk, Mamdouh R.
    Basalious, Emad B.
    Badr, Kamal A.
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [3] Validation of an UPLC-MS/MS Method for Quantitative Analysis of Raltegravir in Human Plasma Samples
    Fortuna, Serena
    Ragazzoni, Enzo
    Lisi, Lucia
    Di Giambenedetto, Simona
    Fabbiani, Massimiliano
    Navarra, Pierluigi
    THERAPEUTIC DRUG MONITORING, 2013, 35 (02) : 258 - 263
  • [4] UPLC-MS/MS-Based Analysis of Trastuzumab in Plasma Samples: Application in Breast Cancer Patients Sample Monitoring
    Sheikh, Aadil Ahmad
    Alam, Ozair
    Rub, Rehan Abdur
    Iqbal, Muzaffar
    Medhi, Kunjahari
    Alsalman, Abdulkhaliq J.
    Imran, Mohd
    Alshehri, Sultan
    Ghoneim, Mohammed M.
    Shakeel, Faiyaz
    PROCESSES, 2022, 10 (03)
  • [5] Development of an UPLC-MS/MS Method for Quantitative Analysis of Clotrimazole in Human Plasma Samples
    Lisi, Lucia
    Ciotti, Gabriella Maria Pia
    Navarra, Pierluigi
    SEPARATIONS, 2020, 7 (04) : 1 - 9
  • [6] A novel, rapid and simple UPLC-MS/MS method for quantification of favipiravir in human plasma: Application to a bioequivalence study
    Rezk, Mamdouh R.
    Badr, Kamal A.
    Abdel-Naby, Naglaa S.
    Ayyad, Magy M.
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (07)
  • [7] UPLC-MS/MS Method Applied for the Analysis of 4 Primary Immunosuppressive Agents in Patients' Samples
    Kunicki, P. K.
    Was, J.
    Boczek, A.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 731 - 731
  • [8] UPLC-MS/MS method for fluconazole determination in plasma and its application in Mexican patients with candidaemia
    Rivera, Karla Paulina Valero
    Aquino, Martin Magana
    Azua, Julia Sagahon
    Mendez, Maria del Carmen Romero
    Garibay, Susanna Edith Medellin
    Segovia, Rosa del Carmen Milan
    Gutierrez, Fidel Martinez
    Moreno, Silvia Romano
    BIOANALYSIS, 2024, 16 (19-20) : 1045 - 1053
  • [9] Vertical Transfer of Metabolites Detectable from Newborn's Dried Blood Spot Samples Using UPLC-MS: A Chemometric Study
    Olarini, Alessandra
    Ernst, Madeleine
    Gurdeniz, Gozde
    Kim, Min
    Brustad, Nicklas
    Bonnelykke, Klaus
    Cohen, Arieh
    Hougaard, David
    Lasky-Su, Jessica
    Bisgaard, Hans
    Chawes, Bo
    Rasmussen, Morten Arendt
    METABOLITES, 2022, 12 (02)
  • [10] Validation and application of an UPLC-MS/MS method for the quantification of synthetic cannabinoids in urine samples and analysis of seized materials from the Portuguese market
    Simoes, Susana Sadler
    Silva, Ines
    Ajenjo, Antonio Castanera
    Dias, Mario Joao
    FORENSIC SCIENCE INTERNATIONAL, 2014, 243 : 117 - 125