Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19

被引:1
作者
Yang, Philip [1 ]
Gregory, Ismail A. [1 ]
Robichaux, Chad [2 ]
Holder, Andre L. [1 ]
Martin, Greg S. [1 ]
Esper, Annette M. [1 ]
Kamaleswaran, Rishikesan [2 ,3 ]
Gichoya, Judy W. [4 ]
Bhavani, Sivasubramanium V. [1 ]
机构
[1] Emory Univ, Div Pulm Allergy Crit Care & Sleep Med, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Biomed Informat, Atlanta, GA USA
[3] Duke Univ, Sch Med, Dept Surg, Durham, NC USA
[4] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
基金
美国国家卫生研究院;
关键词
acute respiratory failure; COVID-19; high-flow nasal cannula; machine learning; HYPOXEMIC RESPIRATORY-FAILURE; PULSE OXIMETRY; OXYGEN-THERAPY; DATA QUALITY; VENTILATION; BIAS; CARE; RACE;
D O I
10.1097/CCE.0000000000001059
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
OBJECTIVES:To develop and validate machine learning (ML) models to predict high-flow nasal cannula (HFNC) failure in COVID-19, compare their performance to the respiratory rate-oxygenation (ROX) index, and evaluate model accuracy by self-reported race.DESIGN:Retrospective cohort study.SETTING:Four Emory University Hospitals in Atlanta, GA.PATIENTS:Adult patients hospitalized with COVID-19 between March 2020 and April 2022 who received HFNC therapy within 24 hours of ICU admission were included.INTERVENTIONS:None.MEASUREMENTS AND MAIN RESULTS:Four types of supervised ML models were developed for predicting HFNC failure (defined as intubation or death within 7 d of HFNC initiation), using routine clinical variables from the first 24 hours of ICU admission. Models were trained on the first 60% (n = 594) of admissions and validated on the latter 40% (n = 390) of admissions to simulate prospective implementation. Among 984 patients included, 317 patients (32.2%) developed HFNC failure. eXtreme Gradient Boosting (XGB) model had the highest area under the receiver-operator characteristic curve (AUROC) for predicting HFNC failure (0.707), and was the only model with significantly better performance than the ROX index (AUROC 0.616). XGB model had significantly worse performance in Black patients compared with White patients (AUROC 0.663 vs. 0.808, p = 0.02). Racial differences in the XGB model were reduced and no longer statistically significant when restricted to patients with nonmissing arterial blood gas data, and when XGB model was developed to predict mortality (rather than the composite outcome of failure, which could be influenced by biased clinical decisions for intubation).CONCLUSIONS:Our XGB model had better discrimination for predicting HFNC failure in COVID-19 than the ROX index, but had racial differences in accuracy of predictions. Further studies are needed to understand and mitigate potential sources of biases in clinical ML models and to improve their equitability.
引用
收藏
页数:10
相关论文
共 50 条
[41]   High-flow nasal cannula versus noninvasive ventilation in patients with COVID-19: a systematic review and meta-analysis [J].
He, Yuewen ;
Liu, Na ;
Zhuang, Xuhui ;
Wang, Xia ;
Ma, Wuhua .
THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2022, 16
[42]   A case report of pneumomediastinum in a COVID-19 patient treated with high-flow nasal cannula and review of the literature: Is this a "spontaneous" complication? [J].
Cancelliere, Anna ;
Procopio, Giada ;
Mazzitelli, Maria ;
Lio, Elena ;
Petulla, Maria ;
Serapide, Francesca ;
Pelle, Maria Chiara ;
Davoli, Chiara ;
Trecarichi, Enrico Maria ;
Torti, Carlo .
CLINICAL CASE REPORTS, 2021, 9 (05)
[43]   High-Flow Nasal Cannula, a Boon or a Bane for COVID-19 Patients? An Evidence-Based Review [J].
Singh, Abhishek ;
Khanna, Puneet ;
Sarkar, Soumya .
CURRENT ANESTHESIOLOGY REPORTS, 2021, 11 (02) :101-106
[44]   Predictors of failure of high flow nasal cannula failure in acute hypoxemic respiratory failure due to COVID-19 [J].
Garner, Orlando ;
Dongarwar, Deepa ;
Salihu, Hamisu M. ;
Perez, Jairo H. Barrantes ;
Abraham, Jocelyn ;
McBride, Cameron ;
Mathew, Sindhu ;
Antony, Preethi ;
Collins, Keegan ;
Richards, Katherine L. ;
Howard, Christopher M. .
RESPIRATORY MEDICINE, 2021, 185
[45]   High-flow nasal cannula oxygen therapy in acute hypoxemic respiratory failure and COVID-19-related respiratory failure [J].
Frat, Jean-Pierre ;
Marchasson, Laura ;
Arrive, Francois ;
Coudroy, Remi .
JOURNAL OF INTENSIVE MEDICINE, 2023, 3 (01) :20-26
[46]   High-flow nasal cannula therapy in patients with COVID-19 in intensive care units in a country with limited resources: a single-center experience [J].
Phan, Anh-Minh Vu ;
Hoang, Hai-Yen Thi ;
Do, Thanh-Son Truong ;
Hoang, Trung Quoc ;
Van Phan, Thuan ;
Huynh, Nguyet-Anh Phuong ;
Le, Khoi Minh .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (08)
[47]   Prognosis of mechanically ventilated patients with COVID-19 after failure of high-flow nasal cannula: a retrospective cohort study [J].
Dong-gon Hyun ;
Su Yeon Lee ;
Jee Hwan Ahn ;
Sang-Bum Hong ;
Chae-Man Lim ;
Younsuck Koh ;
Jin Won Huh .
Respiratory Research, 25
[48]   Surgical mask on top of high-flow nasal cannula improves oxygenation in critically ill COVID-19 patients with hypoxemic respiratory failure [J].
Montiel, Virginie ;
Robert, Arnaud ;
Robert, Annie ;
Nabaoui, Anas ;
Marie, Tourneux ;
Mestre, Natalia Morales ;
Guillaume, Maerckx ;
Laterre, Pierre-Francois ;
Wittebole, Xavier .
ANNALS OF INTENSIVE CARE, 2020, 10 (01)
[49]   High-Flow Nasal Oxygen and Noninvasive Ventilation for COVID-19 [J].
Al-Dorzi, Hasan M. ;
Kress, John ;
Arabi, Yaseen M. .
CRITICAL CARE CLINICS, 2022, 38 (03) :601-621
[50]   Application of high-flow nasal cannula in hypoxemic patients with COVID-19: a retrospective cohort study [J].
Hu, Ming ;
Zhou, Qiang ;
Zheng, Ruiqiang ;
Li, Xuyan ;
Ling, Jianmin ;
Chen, Yumei ;
Jia, Jing ;
Xie, Cuihong .
BMC PULMONARY MEDICINE, 2020, 20 (01)