Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19

被引:1
作者
Yang, Philip [1 ]
Gregory, Ismail A. [1 ]
Robichaux, Chad [2 ]
Holder, Andre L. [1 ]
Martin, Greg S. [1 ]
Esper, Annette M. [1 ]
Kamaleswaran, Rishikesan [2 ,3 ]
Gichoya, Judy W. [4 ]
Bhavani, Sivasubramanium V. [1 ]
机构
[1] Emory Univ, Div Pulm Allergy Crit Care & Sleep Med, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Biomed Informat, Atlanta, GA USA
[3] Duke Univ, Sch Med, Dept Surg, Durham, NC USA
[4] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
基金
美国国家卫生研究院;
关键词
acute respiratory failure; COVID-19; high-flow nasal cannula; machine learning; HYPOXEMIC RESPIRATORY-FAILURE; PULSE OXIMETRY; OXYGEN-THERAPY; DATA QUALITY; VENTILATION; BIAS; CARE; RACE;
D O I
10.1097/CCE.0000000000001059
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
OBJECTIVES:To develop and validate machine learning (ML) models to predict high-flow nasal cannula (HFNC) failure in COVID-19, compare their performance to the respiratory rate-oxygenation (ROX) index, and evaluate model accuracy by self-reported race.DESIGN:Retrospective cohort study.SETTING:Four Emory University Hospitals in Atlanta, GA.PATIENTS:Adult patients hospitalized with COVID-19 between March 2020 and April 2022 who received HFNC therapy within 24 hours of ICU admission were included.INTERVENTIONS:None.MEASUREMENTS AND MAIN RESULTS:Four types of supervised ML models were developed for predicting HFNC failure (defined as intubation or death within 7 d of HFNC initiation), using routine clinical variables from the first 24 hours of ICU admission. Models were trained on the first 60% (n = 594) of admissions and validated on the latter 40% (n = 390) of admissions to simulate prospective implementation. Among 984 patients included, 317 patients (32.2%) developed HFNC failure. eXtreme Gradient Boosting (XGB) model had the highest area under the receiver-operator characteristic curve (AUROC) for predicting HFNC failure (0.707), and was the only model with significantly better performance than the ROX index (AUROC 0.616). XGB model had significantly worse performance in Black patients compared with White patients (AUROC 0.663 vs. 0.808, p = 0.02). Racial differences in the XGB model were reduced and no longer statistically significant when restricted to patients with nonmissing arterial blood gas data, and when XGB model was developed to predict mortality (rather than the composite outcome of failure, which could be influenced by biased clinical decisions for intubation).CONCLUSIONS:Our XGB model had better discrimination for predicting HFNC failure in COVID-19 than the ROX index, but had racial differences in accuracy of predictions. Further studies are needed to understand and mitigate potential sources of biases in clinical ML models and to improve their equitability.
引用
收藏
页数:10
相关论文
共 50 条
[31]   Clinical outcomes of high-flow nasal cannula in COVID-19 associated postextubation respiratory failure. A single-centre case series [J].
Simioli, Francesca ;
Annunziata, Anna ;
Langella, Gerardo ;
Polistina, Giorgio E. ;
Martino, Maria ;
Fiorentino, Giuseppe .
ANAESTHESIOLOGY INTENSIVE THERAPY, 2020, 52 (05) :373-376
[32]   The Impact of High-Flow Nasal Cannula on Olfactory Function [J].
Adiyeke, Esra ;
Saatci, Ozlem ;
Coskun, Nilufer ;
Kiziltepe, Halide F. Uludag ;
Dogru, Orhan U. ;
Bakan, Nurten .
RESPIRATORY CARE, 2020, 65 (08) :1141-1146
[33]   Bronchopleural Fistula after High-flow Nasal Cannula use in Patient with COVID-19 [J].
Venkateswaran, Vineeta ;
Chaturvedi, Apoorv ;
Soni, Kapil D. ;
Aggarwal, Richa ;
Trikha, Anjan .
INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (07) :830-831
[34]   High-Flow Nasal Cannula for COVID-19 Patients: A Multicenter Retrospective Study in China [J].
Duan, Jun ;
Zeng, Jia ;
Deng, Puyu ;
Ni, Zhong ;
Lu, Rongli ;
Xia, Wenxi ;
Jing, Guoqiang ;
Su, Xiaoping ;
Ehrmann, Stephan ;
Zhang, Wei ;
Li, Jie .
FRONTIERS IN MOLECULAR BIOSCIENCES, 2021, 8
[35]   Comparison of High-Flow Nasal Cannula and Noninvasive Ventilation in Acute Hypoxemic Respiratory Failure Due to Severe COVID-19 Pneumonia [J].
Nair, Parvathy Ramachandran ;
Haritha, Damarla ;
Behera, Srikant ;
Kayina, Choro Athiphro ;
Maitra, Souvik ;
Anand, Rahul Kumar ;
Ray, Bikash Ranjan ;
Soneja, Manish ;
Subramaniam, Rajeshwari ;
Baidya, Dalim Kumar .
RESPIRATORY CARE, 2021, 66 (12) :1824-1830
[36]   Respiratory rate-oxygenation (ROX) index for predicting high-flow nasal cannula failure in patients with and without COVID-19 [J].
Kwon, Hyojeong ;
Ha, Seung Won ;
Kim, Boram ;
Chae, Bora ;
Kim, Sang-Min ;
Hong, Seok-In ;
Kim, June-Sung ;
Kim, Youn-Jung ;
Ryoo, Seung Mok ;
Kim, Won Young .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2024, 75 :53-58
[37]   Effectiveness of the use of a high-flow nasal cannula to treat COVID-19 patients and risk factors for failure: a meta-analysis [J].
Xu, Dong-yang ;
Dai, Bing ;
Tan, Wei ;
Zhao, Hong-wen ;
Wang, Wei ;
Kang, Jian .
THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2022, 16
[38]   Factors associated with failure of high-flow nasal cannula oxygen therapy in patients with severe COVID-19: a retrospective case series [J].
Ma, Xiao-Huan ;
An, Meng-Meng ;
Yin, Fang ;
Zhang, Jie ;
Peng, Meng-Yun ;
Guan, Hong ;
Gong, Ping .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2022, 50 (05)
[39]   High-flow Nasal Cannula therapy: A feasible treatment for vulnerable elderly COVID-19 patients in the wards [J].
van Steenkiste, Job ;
van Herwerden, Michael C. ;
Weller, Dolf ;
van den Bout, Christiaan J. ;
Ruiter, Rikje ;
den Hollander, Jan G. ;
El Moussaoui, Rachida ;
Verhoeven, Gert T. ;
van Noord, Charlotte ;
van den Dorpel, Marinus A. .
HEART & LUNG, 2021, 50 (05) :654-659
[40]   Use of high-flow nasal cannula and noninvasive ventilation in patients with COVID-19: A multicenter observational study [J].
Duan, Jun ;
Chen, Baixu ;
Liu, Xiaoyi ;
Shu, Weiwei ;
Zhao, Wei ;
Li, Ji ;
Li, Yishi ;
Hong, Yueling ;
Pan, Longfang ;
Wang, Ke .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 46 :276-281