Validation and application of the square wave voltammetry method for the electrochemical determination of eszopiclone in pharmaceutical formulations and human biological fluids using glassy carbon electrode

被引:1
|
作者
Alghamdi, Ali F. [1 ]
机构
[1] Taibah Univ, Coll Sci, Chem Dept, Medina 30002, Saudi Arabia
关键词
Square wave voltammetry; Cyclic voltammetry; Differential pulse voltammetry; Reduction; Eszopiclone; GC electrode; PURE;
D O I
10.1016/j.jksus.2024.103408
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A buffer solution of Britton-Robinson (B-R) pH 6.5 was utilized to validate and apply a square wave voltammetry (SWV) method for the electrochemical determination of Eszopiclone (ESP) in pharmaceuticals and biological samples. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were employed in the initial study of the voltammetric behavior of the ESP compound. The rotating glassy carbon (GC) indicator electrode (2.0 mm2), Pt auxiliary electrode, and Ag/AgCl reference electrode were used for ESP determination. ESP was analyzed to produce a sharp reduction peak at a potential of -750 mV. The best shape and high sensitivity of SWV cathodic current for ESP, were observed using GC electrode, B-R, pH 6.5, accumulation time (tacc) of 60-second, accumulation potential (Eacc) of - 0.1 V, amplitude voltage of 150 mV, frequency of 15 Hz, scan rate of 150 mV s-1, and stirrer rate of 1000 round per minute (rpm). The electroanalytical performance of the SWV method was evaluated through study of repeatability, stability, calibration curve, recovery, and limits of detection and quantification (LOD,LOQ). Under the optimal conditions, the SWV response was linear in the range from 3 x 10-6 to 5 x 10-5 mol/L (n = 10). The SWV method achieved a LOD of 1.9 x 10-8 mol/L (7.5 ppb), and a LOQ of 6.41 x 10- 8 mol L-1 (24.93 ppb). The validated SWV method was appeared the good repeatability, sensitivity and stability for the determination of ESP. It was given a very stable SWV current for 90 min, with a 0.141 % relative standard deviation (RSD%). The SWV method was applied to the determination of ESP in pharmaceutical tablets and biological samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Determination of Chlorpromazine in Livestock and Poultry Meat by Polydopamine@Nanosilver Modified Glassy Carbon Electrode Based on Square Wave Voltammetry
    Zou Y.
    Duan N.
    Gu F.
    Huang H.
    Zhao X.
    Liu G.
    Luo Z.
    Shipin Kexue/Food Science, 2023, 44 (04): : 292 - 299
  • [42] Indirect determination of formaldehyde by square-wave voltammetry based on the electrochemical oxidation of 3,5-diacetyl-1,4-dihydrolutidine using an unmodified glassy-carbon electrode
    Pinto, Gabriel F.
    Rocha, Diego P.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    Silva, Sidnei G.
    TALANTA, 2019, 198 : 237 - 241
  • [43] Development of an electrochemical method for the determination of bicalutamide at the SWCNT/CPE in pharmaceutical preparations and human biological fluids
    Pandit, Umar J.
    Khan, Imran
    Wankar, Sneha
    Raj, K. K.
    Limaye, S. N.
    ANALYTICAL METHODS, 2015, 7 (24) : 10192 - 10198
  • [44] Electrochemical Determination of Paraquat in Tomato at Ag/NP-Modified Graphite Electrode Using Square Wave Voltammetry
    Farahi, A.
    Achak, M.
    El Gaini, L.
    El Mhammedi, M. A.
    Bakasse, M.
    FOOD ANALYTICAL METHODS, 2016, 9 (01) : 139 - 147
  • [45] Determination of Folic Acid in Pharmaceutical Preparations by Square-Wave Voltammetry Using a Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Satkovska, Petra
    Svorc, L'ubomir
    CHEMICKE LISTY, 2015, 109 (10): : 788 - 793
  • [46] Electrochemical Determination of Paraquat in Tomato at Ag/NP-Modified Graphite Electrode Using Square Wave Voltammetry
    A. Farahi
    M. Achak
    L. El Gaini
    M. A. El Mhammedi
    M. Bakasse
    Food Analytical Methods, 2016, 9 : 139 - 147
  • [47] Electrochemical Sensor for Square Wave Voltammetric Determination of Clozapine by Glassy Carbon Electrode Modified by WO3 Nanoparticles
    Fat'hi, Mohammad Reza
    Almasifar, Dariush
    IEEE SENSORS JOURNAL, 2017, 17 (18) : 6069 - 6076
  • [48] Electrochemical Determination of Amlodipine in Pharmaceutical Formulations and in Human Urine Using a Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Svorc, L'ubomir
    CHEMICKE LISTY, 2015, 109 (06): : 463 - 469
  • [49] A Sensor for Determination of Tramadol in Pharmaceutical Preparations and Biological Fluids Based on Multi-Walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Afrasiabi, Mohammad
    Zad, Zeinab Rezayati
    Kianipour, Shokat
    Babaei, Ali
    Taheri, Ali Reza
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1106 - 1112
  • [50] Electrochemical determination of nonylphenol using differential pulse voltammetry based on a graphene-DNA-modified glassy carbon electrode
    Zeng, Lixuan
    Zhang, Aizhen
    Zhu, Xiaohua
    Zhang, Chuyi
    Liang, Yong
    Nan, Junmin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 703 : 153 - 157