Validation and application of the square wave voltammetry method for the electrochemical determination of eszopiclone in pharmaceutical formulations and human biological fluids using glassy carbon electrode

被引:1
|
作者
Alghamdi, Ali F. [1 ]
机构
[1] Taibah Univ, Coll Sci, Chem Dept, Medina 30002, Saudi Arabia
关键词
Square wave voltammetry; Cyclic voltammetry; Differential pulse voltammetry; Reduction; Eszopiclone; GC electrode; PURE;
D O I
10.1016/j.jksus.2024.103408
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A buffer solution of Britton-Robinson (B-R) pH 6.5 was utilized to validate and apply a square wave voltammetry (SWV) method for the electrochemical determination of Eszopiclone (ESP) in pharmaceuticals and biological samples. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were employed in the initial study of the voltammetric behavior of the ESP compound. The rotating glassy carbon (GC) indicator electrode (2.0 mm2), Pt auxiliary electrode, and Ag/AgCl reference electrode were used for ESP determination. ESP was analyzed to produce a sharp reduction peak at a potential of -750 mV. The best shape and high sensitivity of SWV cathodic current for ESP, were observed using GC electrode, B-R, pH 6.5, accumulation time (tacc) of 60-second, accumulation potential (Eacc) of - 0.1 V, amplitude voltage of 150 mV, frequency of 15 Hz, scan rate of 150 mV s-1, and stirrer rate of 1000 round per minute (rpm). The electroanalytical performance of the SWV method was evaluated through study of repeatability, stability, calibration curve, recovery, and limits of detection and quantification (LOD,LOQ). Under the optimal conditions, the SWV response was linear in the range from 3 x 10-6 to 5 x 10-5 mol/L (n = 10). The SWV method achieved a LOD of 1.9 x 10-8 mol/L (7.5 ppb), and a LOQ of 6.41 x 10- 8 mol L-1 (24.93 ppb). The validated SWV method was appeared the good repeatability, sensitivity and stability for the determination of ESP. It was given a very stable SWV current for 90 min, with a 0.141 % relative standard deviation (RSD%). The SWV method was applied to the determination of ESP in pharmaceutical tablets and biological samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Novel Method for the Determination of Haemoglobin Phenotypes by Cyclic Voltammetry using Glassy Carbon Electrode
    Ogunlesi, M.
    Okiei, W.
    Akanmu, A. S.
    Popoola, T.
    Okafor, K.
    Akore, O.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (11): : 1593 - 1606
  • [32] Method validation in quantitative electrochemical analysis of colchicine using glassy carbon electrode
    Bodoki, Ede
    Sandulescu, Robert
    Roman, Liviu
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2007, 5 (03): : 766 - 778
  • [33] SQUARE WAVE VOLTAMMETRIC DETERMINATION OF LEAD IN COMMERCIAL KOHL USING A GLASSY CARBON ELECTRODE
    Saha, M. A.
    Alia, M.
    Rebiai, A.
    Lanez, T.
    JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2011, 3 (02) : 155 - 164
  • [34] Electrochemical Kinetics and Detection of Paracetamol by Stevensite-Modified Carbon Paste Electrode in Biological Fluids and Pharmaceutical Formulations
    Gharous, Moaad
    Bounab, Loubna
    Pereira, Fernando J.
    Choukairi, Mohamed
    Lopez, Roberto
    Aller, A. Javier
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (14)
  • [35] Simultaneous Electrochemical Preconcentration and Determination of Dopamine and Uric acid by Square-Wave Adsorptive Stripping Voltammetry using a Poly(Safranine O)-Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Arpaci, Rabia Bozdogan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (06): : 2775 - 2789
  • [36] The Determination of Dopamine Using Glassy Carbon Electrode Pretreated by a Simple Electrochemical Method
    Huang, De-Qian
    Chen, Cheng
    Wu, Yi-Ming
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5510 - 5520
  • [37] Electrochemical determination of ascorbic acid and paracetamol in pharmaceutical formulations using a glassy carbon electrode modified with multi-wall carbon nanotubes dispersed in polyhistidine
    Dalmasso, Pablo R.
    Pedano, Maria L.
    Rivas, Gustavo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 732 - 736
  • [38] Simultaneous determination of caffeine and acetaminophen in drug formulations by square-wave voltammetry using a chemically modified electrode
    Zen, JM
    Ting, YS
    ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) : 175 - 180
  • [39] Simultaneous Determination of Vitamin E and Vitamin K in Food Supplements Using Adsorptive Stripping Square-Wave Voltammetry at Glassy Carbon Electrode
    Kastrati, Gylxhane
    Jashari, Granit
    Sys, Milan
    Svecova, Blanka
    Arbneshi, Tahir
    Metelka, Radovan
    Bilkova, Zuzana
    Korecka, Lucie
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [40] A Glassy Carbon Electrode for the Determination of Linagliptin, an Antidiabetic Drug in Pure Form, Tablets and Some Biological Fluids by Adsorptive Stripping Voltammetry
    Gahlan, Ahmed A.
    Haredy, Ahmed M.
    Derayea, Sayed M.
    Omar, Mahmoud A.
    Saleh, Gamal A.
    CURRENT PHARMACEUTICAL DESIGN, 2021, 27 (20) : 2415 - 2424