Validation and application of the square wave voltammetry method for the electrochemical determination of eszopiclone in pharmaceutical formulations and human biological fluids using glassy carbon electrode

被引:1
|
作者
Alghamdi, Ali F. [1 ]
机构
[1] Taibah Univ, Coll Sci, Chem Dept, Medina 30002, Saudi Arabia
关键词
Square wave voltammetry; Cyclic voltammetry; Differential pulse voltammetry; Reduction; Eszopiclone; GC electrode; PURE;
D O I
10.1016/j.jksus.2024.103408
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A buffer solution of Britton-Robinson (B-R) pH 6.5 was utilized to validate and apply a square wave voltammetry (SWV) method for the electrochemical determination of Eszopiclone (ESP) in pharmaceuticals and biological samples. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were employed in the initial study of the voltammetric behavior of the ESP compound. The rotating glassy carbon (GC) indicator electrode (2.0 mm2), Pt auxiliary electrode, and Ag/AgCl reference electrode were used for ESP determination. ESP was analyzed to produce a sharp reduction peak at a potential of -750 mV. The best shape and high sensitivity of SWV cathodic current for ESP, were observed using GC electrode, B-R, pH 6.5, accumulation time (tacc) of 60-second, accumulation potential (Eacc) of - 0.1 V, amplitude voltage of 150 mV, frequency of 15 Hz, scan rate of 150 mV s-1, and stirrer rate of 1000 round per minute (rpm). The electroanalytical performance of the SWV method was evaluated through study of repeatability, stability, calibration curve, recovery, and limits of detection and quantification (LOD,LOQ). Under the optimal conditions, the SWV response was linear in the range from 3 x 10-6 to 5 x 10-5 mol/L (n = 10). The SWV method achieved a LOD of 1.9 x 10-8 mol/L (7.5 ppb), and a LOQ of 6.41 x 10- 8 mol L-1 (24.93 ppb). The validated SWV method was appeared the good repeatability, sensitivity and stability for the determination of ESP. It was given a very stable SWV current for 90 min, with a 0.141 % relative standard deviation (RSD%). The SWV method was applied to the determination of ESP in pharmaceutical tablets and biological samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Square-wave Adsorptive Anodic Stripping Voltammetric Determination of Antidiabetic Drug Linagliptin in Pharmaceutical Formulations and Biological Fluids Using a Pencil Graphite Electrode
    Ahmed H. Naggar
    Gamal A. Saleh
    Mahmoud A. Omar
    Ahmed M. Haredy
    Sayed M. Derayea
    Analytical Sciences, 2020, 36 : 1031 - 1038
  • [22] Determination of Nicotine at a Carbon Paste Electrode Using Square-Wave Voltammetry
    Stoces, Matej
    Ksandrova, Iveta
    Svancara, Ivan
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 196 - 200
  • [23] Simple and rapid determination of clonidine in pharmaceutical samples by voltammetry using a bare glassy carbon electrode
    Moreira, Debora A. R.
    Pimentel, Dilton M.
    Arrieiro, Mariane O. B.
    Barbosa, Sandro L.
    da Silva, Rodrigo A. B.
    dos Santos, Wallans T. P.
    ELECTROANALYSIS, 2023, 35 (05)
  • [24] Electrochemical behavior of an anti-cancer drug at glassy carbon electrode and its determination in pharmaceutical formulations
    Kalanur, Shankara S.
    Seetharamappa, Jaldappagari
    Mamatha, Gangeenahalli P.
    Hadagali, Manjunatha D.
    Kandagal, Pradeep B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2008, 3 (07): : 756 - 767
  • [25] Application of Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode for Determination of Mefenamic Acid in Pharmaceutical Preparations and Biological Fluids
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Zad, Zeinab Rezayati
    Babei, Ali
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1113 - 1121
  • [26] A non-toxic poly(resorcinol) modified glassy carbon electrode for highly selective square wave voltammetry determination of aspirin in tablet formulations and human urine samples
    Kassa, Adane
    Bitew, Zelalem
    Abebe, Atakilt
    SENSING AND BIO-SENSING RESEARCH, 2023, 39
  • [27] Highly sensitive electrocatalytic determination of pyrazinamide using a modified poly(glycine) glassy carbon electrode by square-wave voltammetry
    Bruno R. L. Ferraz
    Fernando R. F. Leite
    Andréa R. Malagutti
    Journal of Solid State Electrochemistry, 2016, 20 : 2509 - 2516
  • [28] Optimization of Square Wave Voltammetry (SWV) Parameters by Design of Experiment (DoE) Methodologies for the Determination of Mifepristone at Glassy Carbon Electrode (GCE)
    Makwakwa, Tlou A.
    Mafa, Potlako J.
    Nyoni, Hlengilizwe
    Msagati, Titus A. M.
    ELECTROANALYSIS, 2022, 34 (07) : 1103 - 1113
  • [29] Determination of vitamin E in margarines and edible oils using square wave anodic stripping voltammetry with a glassy carbon paste electrode
    Sys, Milan
    Svecova, Blanka
    Svancara, Ivan
    Metelka, Radovan
    FOOD CHEMISTRY, 2017, 229 : 621 - 627
  • [30] Enhanced application of square wave voltammetry with glassy carbon electrode coupled to multivariate calibration tools for the determination of B6 and B12 vitamins in pharmaceutical preparations
    Hernández, SR
    Ribero, GG
    Goicoechea, HC
    TALANTA, 2003, 61 (05) : 743 - 753