Validation and application of the square wave voltammetry method for the electrochemical determination of eszopiclone in pharmaceutical formulations and human biological fluids using glassy carbon electrode

被引:1
|
作者
Alghamdi, Ali F. [1 ]
机构
[1] Taibah Univ, Coll Sci, Chem Dept, Medina 30002, Saudi Arabia
关键词
Square wave voltammetry; Cyclic voltammetry; Differential pulse voltammetry; Reduction; Eszopiclone; GC electrode; PURE;
D O I
10.1016/j.jksus.2024.103408
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A buffer solution of Britton-Robinson (B-R) pH 6.5 was utilized to validate and apply a square wave voltammetry (SWV) method for the electrochemical determination of Eszopiclone (ESP) in pharmaceuticals and biological samples. The cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were employed in the initial study of the voltammetric behavior of the ESP compound. The rotating glassy carbon (GC) indicator electrode (2.0 mm2), Pt auxiliary electrode, and Ag/AgCl reference electrode were used for ESP determination. ESP was analyzed to produce a sharp reduction peak at a potential of -750 mV. The best shape and high sensitivity of SWV cathodic current for ESP, were observed using GC electrode, B-R, pH 6.5, accumulation time (tacc) of 60-second, accumulation potential (Eacc) of - 0.1 V, amplitude voltage of 150 mV, frequency of 15 Hz, scan rate of 150 mV s-1, and stirrer rate of 1000 round per minute (rpm). The electroanalytical performance of the SWV method was evaluated through study of repeatability, stability, calibration curve, recovery, and limits of detection and quantification (LOD,LOQ). Under the optimal conditions, the SWV response was linear in the range from 3 x 10-6 to 5 x 10-5 mol/L (n = 10). The SWV method achieved a LOD of 1.9 x 10-8 mol/L (7.5 ppb), and a LOQ of 6.41 x 10- 8 mol L-1 (24.93 ppb). The validated SWV method was appeared the good repeatability, sensitivity and stability for the determination of ESP. It was given a very stable SWV current for 90 min, with a 0.141 % relative standard deviation (RSD%). The SWV method was applied to the determination of ESP in pharmaceutical tablets and biological samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Electrochemical Behavior of Atorvastatin at Glassy Carbon Electrode and its Direct Determination in Pharmaceutical Preparations by Square Wave and Differential Pulse Voltammetry
    Yilmaz, B.
    Kaban, S.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 78 (03) : 360 - 367
  • [2] Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids
    Alghamdi, Ali F.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) : 363 - 369
  • [3] Graphene oxide modified glassy carbon electrode for determination of linagliptin in dosage form, biological fluids, and rats' feces using square wave voltammetry
    Haredy, Ahmed M.
    Derayea, Sayed M.
    Gahlan, Ahmed A.
    Omar, Mahmoud A.
    Saleh, Gamal A.
    ARABIAN JOURNAL OF CHEMISTRY, 2022, 15 (03)
  • [4] Determination of Amlodipine in pharmaceutical formulations by differential-pulse voltammetry with a glassy carbon electrode
    Altiokka, G
    Dogrukol-Ak, D
    Tunçel, M
    Aboul-Enein, HY
    ARCHIV DER PHARMAZIE, 2002, 335 (2-3) : 104 - 108
  • [5] Disposable Pencil Graphite Electrode for Ciprofloxacin Determination in Pharmaceutical Formulations by Square Wave Voltammetry
    Alves, Guilherme Figueira
    Lisboa, Thalles Pedrosa
    de Faria, Lucas Vinicius
    de Farias, Davi Marques
    Costa Matos, Maria Auxiliadora
    Matos, Renato Camargo
    ELECTROANALYSIS, 2021, 33 (02) : 543 - 549
  • [6] Electrochemical Behaviour of Trimebutine at Activated Glassy Carbon Electrode and its Direct Determination in Urine and Pharmaceutics by Square Wave and Differential Pulse Voltammetry
    Elqudaby, H. M.
    Mohamed, Gehad G.
    El Din, Ghada M. G.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (02): : 856 - 869
  • [7] Electrochemical oxidation of prednisolone at glassy carbon electrode and its quantitative determination in human serum and tablets by Osteryoung square wave voltammetry
    Yilmaz, Selahattin
    Skrzypek, Slowomira
    Dilgin, Yusuf
    Yagmur, Sultan
    Coskun, Mahmut
    CURRENT ANALYTICAL CHEMISTRY, 2007, 3 (01) : 41 - 46
  • [8] Simultaneous Determination of Lipophilic Vitamin Esters Using Square-Wave Voltammetry at the Glassy Carbon Electrode
    Jashari, Granit
    Musliu, Arber
    Sys, Milan
    Arbneshi, Tahir
    Mikysek, Tomas
    Svancara, Ivan
    Metelka, Radovan
    ELECTROANALYSIS, 2021, 33 (02) : 537 - 542
  • [9] Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
    Ali F Al-Ghamdi
    Mohamed M Hefnawy
    Abdulrahman A Al-Majed
    Fatallah F Belal
    Chemistry Central Journal, 6
  • [10] Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
    Al-Ghamdi, Ali F.
    Hefnawy, Mohamed M.
    Al-Majed, Abdulrahman A.
    Belal, Fatallah F.
    CHEMISTRY CENTRAL JOURNAL, 2012, 6