Capacitive measurement of infusion fluid volume

被引:0
|
作者
Dziadak, Bogdan [1 ]
Graffstein, Piotr [2 ]
机构
[1] Warsaw Univ Technol, Inst Theory Elect Engn Measurement & Informat Syst, Warsaw, Poland
[2] Inst Elect Engn, Lukasiewicz Res Network, Ul Mieczyslawa Pozaryskiego 28, PL-04703 Warsaw, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2024年 / 100卷 / 05期
关键词
infusion fluid; capacity measurement; volume measurement; NE555;
D O I
10.15199/48.2024.05.49
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
.The article presents a system for monitoring fluid during intravenous infusion. The system is based on a capacitive method in which the change in electrical capacitance of the infusion container is converted into the current volume of the fluid. The capacitor pads of the measurement system are integrated into the housing of the container, facilitating easy installation in hospital conditions without significantly altering the dimensions of the infusion set. The system has been tested with target infusion fluids, and the volume measurement error within the entire measurement range is less than 6%. The current fluid volume is displayed on an LED strip to quickly inform the personnel, and the system also has the capability to provide an alarm for low fluid levels.
引用
收藏
页码:258 / 262
页数:5
相关论文
共 50 条
  • [21] Automatic liver segmentation for volume measurement in CT images
    Lim, Seong-Jae
    Jeong, Yong-Yeon
    Ho, Yo-Sung
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2006, 17 (04) : 860 - 875
  • [22] Clinical Kidney Volume Measurement Accuracy Using NEFROVOL
    Chagot, Lise
    Tobal, Diego
    Peirano, Florencia
    Sarantes, Rodrigo
    Ferrari, Soledad
    Diaz, Silvia
    Noboa, Oscar
    Simini, Franco
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 654 - 659
  • [23] Research on Volume Measurement of Logs Based on Embedded Application
    Zheng, Jishi
    Li, Shaoyi
    Zhang, Shiwen
    Kong, Linghua
    Zhigang, Ding
    IEEE ACCESS, 2023, 11 : 19186 - 19201
  • [24] A DEVICE FOR MEASUREMENT OF VOLUME AND LEAKAGE BY PRESSURE PULSATION MONITORING
    VAUGHAN, NP
    BROWN, RC
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (01) : 1 - 8
  • [25] The accuracy of breast volume measurement methods: A systematic review
    Choppin, S. B.
    Wheat, J. S.
    Gee, M.
    Goyal, A.
    BREAST, 2016, 28 : 121 - 129
  • [26] Measurement of the volume of a leg ulcer using a laser scanner
    Marjanovic, D
    Dugdale, RE
    Vowden, P
    Vowden, KR
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (04) : 535 - 543
  • [27] Stereotactic noninvasive volume measurement compared with geometric measurement for indications and evaluation of gamma knife treatment
    del Valle, R
    Pérez, M
    Ortiz, J
    Ruiz, MSS
    de Anda, S
    Jaramillo, J
    Martínez, M
    Corona, R
    Vivas, I
    Facha, T
    Olmos, R
    Arrieta, A
    Estrada, J
    JOURNAL OF NEUROSURGERY, 2005, 102 : 140 - 142
  • [28] Potato volume measurement based on RGB-D camera
    Long, Yaowei
    Wang, Yuhao
    Zhai, Ziming
    Wu, Li
    Li, Minzan
    Sun, Hong
    Su, Qinghua
    IFAC PAPERSONLINE, 2018, 51 (17): : 515 - 520
  • [29] Lung Nodule Volume Measurement using Digital Chest Tomosynthesis
    Hadhazi, D.
    Czetenyi, B.
    Horvath, A.
    Orban, G.
    Horvath, G.
    Horvath, A.
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 2026 - 2031
  • [30] Volume Measurement of Various Tissues Using the Image J Software
    Rha, Eun Young
    Kim, Ji Min
    Yoo, Gyeol
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (06) : E505 - E506