Single-blind detection, localization, and quantification of methane emissions using continuous path-integrated column measurements

被引:0
|
作者
Blume, Nathan [1 ]
Pernini, Timothy G. [2 ]
Dobler, Jeremy T. [1 ]
Zaccheo, T. Scott [2 ]
McGregor, Doug [1 ]
Bell, Clay [3 ,4 ]
机构
[1] Spectral Sensor Solut LLC, Ft Wayne, IN 46818 USA
[2] Atmospher & Environm Res, Lexington, MA USA
[3] Colorado State Univ, Energy Inst, Ft Collins, CO USA
[4] bpx energy, Denver, CO USA
来源
ELEMENTA-SCIENCE OF THE ANTHROPOCENE | 2024年 / 12卷 / 01期
基金
美国国家环境保护局;
关键词
Methane; Emissions; Controlled release; Continuous monitoring protocol; VARIABILITY; OIL;
D O I
10.1525/elementa.2024.00022
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Path-integrated column measurements with a laser-absorption-based measurement system have been used to detect, locate, and quantify methane emissions from a series of single-blind controlled releases with no prior knowledge of timing, locations, or release rates. System performance was evaluated against metrics defined in the Continuous Monitoring Protocol established by the Colorado State University Methane Emissions Technology Evaluation Center (METEC). This protocol allows more direct comparison of system performance between disparate measurement technologies and is transferable to any test facility. To the authors' knowledge, this work represents the first time the protocol has been directly applied at a test facility other than METEC. This experiment differs from similar tests where releases were conducted from equipment units at fixed locations at METEC by instead conducting releases at random locations anywhere within the central 0.18 km(2) of a 0.35 km(2) unobstructed test site. The releases were much shorter in duration than those conducted in similar testing at METEC. The system detected 25 of 42 releases with metered rates of 0.17-2.15 kg h(-1). The minimum detected emissions rate was 0.22 kg h(-1), and the system demonstrated a 100% detection rate for releases >= 0.65 kg h(-1) when average wind speed was <5 m s(-1). The test site was subdivided into 20 boxes (109 m x 83 m each), and the correct release box was identified in 9 cases, another 9 detections were localized to an adjacent box, and the remaining 7 were attributed elsewhere within the field. The average estimated emission rate bias was -6.1%. The 90% detection limit was 0.89 kg h(-1), while the wind-normalized detection limit was 0.44 (kg h(-1)) (m s(-1))(-1).
引用
收藏
页数:15
相关论文
共 4 条
  • [1] Single-blind determination of methane detection limits and quantification accuracy using aircraft-based LiDAR
    Bell, Clay
    Rutherford, Jeff
    Brandt, Adam
    Sherwin, Evan
    Vaughn, Timothy
    Zimmerle, Daniel
    ELEMENTA-SCIENCE OF THE ANTHROPOCENE, 2022, 10 (01): : 186 - 188
  • [2] Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment
    Ilonze, Chiemezie
    Wang, Jiayang
    Ravikumar, Arvind P.
    Zimmerle, Daniel
    SENSORS, 2024, 24 (13)
  • [3] Detection, localization, and quantification of single-source methane emissions on oil and gas production sites using point-in-space continuous monitoring systems
    Daniels, William S.
    Jia, Meng
    Hammerling, Dorit M.
    ELEMENTA-SCIENCE OF THE ANTHROPOCENE, 2024, 12 (01): : 12016 - 12026
  • [4] Airborne measurements of atmospheric methane column abundance using a pulsed integrated-path differential absorption lidar
    Riris, Haris
    Numata, Kenji
    Li, Steve
    Wu, Stewart
    Ramanathan, Anand
    Dawsey, Martha
    Mao, Jianping
    Kawa, Randolph
    Abshire, James B.
    APPLIED OPTICS, 2012, 51 (34) : 8296 - 8305