Application of internal fixator system for anterior pelvic ring with simultaneous application of sacroiliac screw internal fixation of the posterior pelvic ring in Tile C-type unstable pelvic fractures

被引:1
|
作者
Liu, Zhongbing [1 ]
Zou, Guoyou [1 ]
机构
[1] Yancheng 1 Peoples Hosp, Dept Orthoped, Yancheng 224001, Jiangsu, Peoples R China
关键词
bone screws; fractures; bone; fracture fixation; internal; open fracture reduction; pelvic bones; orthopedic procedures; treatment outcome;
D O I
10.2298/VSP240329051L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. The number of pelvic traumas is increasing globally, mostly due to car accidents but also due to an increasing number of sports and recreational traumas. Tile C-type unstable pelvic trauma (TCUPT) is a kind of high-energy trauma that occurs during traffic accidents or accidents when falling from big heights. The aim of our study was to explore the application of the internal fixation (INFIX) system for the anterior pelvic ring (APR) with simultaneous application of sacroiliac screw (SS) INFIX of the posterior pelvic ring (PPR) in TCUPT. Methods. The subjects (89 of them in total) were recruited among patients with TCUPT from December 2020 to December 2023. A retrospective analysis of the subjects' data was performed, after which the subjects were divided into two groups based on different therapeutic regimens applied: group A (INFIX system for the APR + SS INFIX of the PPR, n = 46) and group B (external fixator for the APR + SS INFIX of the PPR, n = 43). Results.In comparison with group B, group A had a shorter period before the commencement of the first activity after surgery, shorter fracture healing time and joint function recovery time, as well as length of hospital stay (t = 6.623, 4.796, 7.992, and 5.227, respectively, p < 0.05). The surgery duration and bleeding volume showed no significant differences between the two groups (t = 1.433, 1.123, respectively, p > 0.05). The fracture reduction outcomes were better in group A than in group B (Z = 2.058, p < 0.05). The incidence rate of complications was lower in group A than in group B (2.17% vs. . 18.60%) (chi(2) = 4.917, p < 0.05). Conclusion. For patients with TCUPT, the INFIX system for the APR with simultaneous application of SS INFIX of the PPR achieves good fracture reduction outcomes.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [1] Clinical application of anterior ring internal fixator system combined with sacroiliac screw fixation in Tile C pelvic fracture treatment
    Lin Liu
    Shicai Fan
    Donggui Zeng
    Yuhui Chen
    Hui Song
    Letian Zeng
    Dadi Jin
    Journal of Orthopaedic Surgery and Research, 16
  • [2] Clinical application of anterior ring internal fixator system combined with sacroiliac screw fixation in Tile C pelvic fracture treatment
    Liu, Lin
    Fan, Shicai
    Zeng, Donggui
    Chen, Yuhui
    Song, Hui
    Zeng, Letian
    Jin, Dadi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [3] Biomechanics of Anterior Ring Internal Fixation Combined with Sacroiliac Screw Fixation for Tile C3 Pelvic Fractures
    Liu, Lin
    Fan, Shicai
    Chen, Yuhui
    Peng, Yongxing
    Wen, Xiangyuan
    Zeng, Donggui
    Song, Hui
    Jin, Dadi
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [4] One sacroiliac screw for posterior ring fixation in unstable pelvic fractures
    Hosny, Hossam
    Mohamed, Mohamed Ali
    Elsayed, Moustafa
    Marzouk, Ashraf
    Salama, Wael
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 411 - 418
  • [5] Anterior Pelvic External Fixator Versus Subcutaneous Internal Fixator in the Treatment of Anterior Ring Pelvic Fractures
    Cole, Peter A.
    Gauger, Erich M.
    Anavian, Jack
    Ly, Thuan V.
    Morgan, Robert A.
    Heddings, Archie A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (05) : 269 - 277
  • [6] Treatment of Unstable Pelvic Ring Injuries With an Internal Anterior Fixator and Posterior Fixation: Initial Clinical Series
    Vaidya, Rahul
    Colen, Robert
    Vigdorchik, Jonathan
    Tonnos, Fredrick
    Sethi, Anil
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (01) : 1 - 8
  • [7] Modified internal fixator for anterior pelvic ring fractures versus conventional two-screw fixation
    Shenglong Ding
    Xiaojian He
    Guangming Zhang
    Zhiyong Ruan
    Xiaotian Wu
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 533 - 539
  • [8] Modified internal fixator for anterior pelvic ring fractures versus conventional two-screw fixation
    Ding, Shenglong
    He, Xiaojian
    Zhang, Guangming
    Ruan, Zhiyong
    Wu, Xiaotian
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2021, 47 (02) : 533 - 539
  • [9] A Comparative Study of Functional Outcomes in Unstable Pelvic Ring Fractures Treated With Internal Fixator (INFIX) With and Without Sacroiliac Joint Screw Fixation
    Ansari, Muqtadeer
    Vimal, P. V.
    Kesharwani, Arpit K.
    Damkondwar, Saurabh S.
    Kakade, Rohan U.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [10] Percutaneous Sacroiliac Screw Fixation of the Posterior Pelvic Ring
    Iorio, Justin A.
    Jakoi, Andre M.
    Rehman, Saqib
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 511 - +