Artificial intelligence predicts undiagnosed atrial fibrillation in patients with embolic stroke of undetermined source using sinus rhythm electrocardiograms

被引:4
作者
Choi, Jina [1 ]
Kim, Ju Youn [2 ]
Cho, Min Soo [3 ]
Kim, Minsu [4 ]
Kim, Joonghee [5 ]
Oh, Il-Young [1 ]
Cho, Youngjin [1 ]
Lee, Ji Hyun [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Cardiovasc Ctr, Dept Internal Med, Seongnam, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Internal Med,Heart Vasc Stroke Inst,Div Cardi, Seoul, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Internal Med, Seoul, South Korea
[4] Chungnam Natl Univ, Coll Med, Dept Internal Med, Div Cardiol, Daejeon, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Emergency Med, Seongnam, South Korea
关键词
Atrial fibrillation; Artificial intelligence; Prediction model; Twelve-lead electrocardiogram; Multicenter study; Embolic stroke of undetermined source; CRYPTOGENIC STROKE;
D O I
10.1016/j.hrthm.2024.03.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Artificial intelligence (AI)-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation can aid in identifying undiagnosed paroxysmal atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS). OBJECTIVE The purpose of this study was to assess the efficacy of an AI model in identifying AF based on SR ECGs in patients with ESUS. METHODS A transformer-based vision AI model was developed using 737,815 SR ECGs from patients with and without AF to detect current paroxysmal AF or predict the future development of AF within a 2-year period. Probability of AF was calculated from baseline SR ECGs using this algorithm. Its diagnostic performance was further tested in a cohort of 352 ESUS patients from 4 tertiary hospitals, all of whom were monitored using an insertable cardiac monitor (ICM) for AF surveillance. RESULTS Over 25.1-month follow-up, AF episodes lasting >= 1 hour were identified in 58 patients (14.4%) using ICMs. In the receiver operating curve (ROC) analysis, the area under the curve for the AI algorithm to identify AF >= 1 hour was 0.806, which improved to 0.880 after integrating the clinical parameters into the model. The AI algorithm exhibited greater accuracy in identifying longer AF episodes (ROC for AF >= 12 hours: 0.837, for AF >= 24 hours: 0.879) and a temporal trend indicating that the AI-based AF risk score increased as the ECG recording approached the AF onset (P for trend <.0001). CONCLUSIONS Our AI model demonstrated excellent diagnostic performance in predicting AF in patients with ESUS, potentially enhancing patient prognosis through timely intervention and secondary prevention of ischemic stroke in ESUS cohorts.
引用
收藏
页码:1647 / 1655
页数:9
相关论文
共 50 条
  • [21] Predictors of atrial fibrillation after embolic stroke of undetermined source in patients with implantable loop recorders
    Kreimer, Fabienne
    Aweimer, Assem
    El-Battrawy, Ibrahim
    Labedi, Adnan
    Schneider, Ruth
    Haghikia, Arash
    Muegge, Andreas
    Gotzmann, Michael
    NEUROLOGICAL SCIENCES, 2024, 45 (10) : 4903 - 4912
  • [22] Atrial fibrillation after patent foramen ovale closure in patients with embolic stroke of undetermined source
    von Falkenhausen, Aenne S.
    Keidel, Linus M.
    Wischmann, Johannes
    Hoeglinger, Guenter
    Massberg, Steffen
    Kaeaeb, Stefan
    Kellert, Lars
    Sinner, Moritz F.
    EUROPACE, 2024, 26 (06):
  • [23] Multiparametric identification of subclinical atrial fibrillation after an embolic stroke of undetermined source
    Alvise Del Monte
    Francesco Rivezzi
    Enrico Giacomin
    Francesco Peruzza
    Maurizio Del Greco
    Massimiliano Maines
    Federico Migliore
    Alessandro Zorzi
    Federica Viaro
    Alessio Pieroni
    Andrea La Licata
    Claudio Baracchini
    Emanuele Bertaglia
    Neurological Sciences, 2023, 44 : 979 - 988
  • [24] The pads score - predicting incident atrial fibrillation in embolic stroke of undetermined source
    Chattopadhyay, Rahul
    Warburton, Elizabeth
    Tsampasian, Vasiliki
    Potter, John
    Mukherjee, Trisha
    Bhalraam, U.
    Vassiliou, Vassilios
    Khadjooi, Kayvan
    Ring, Liam
    Pugh, Peter
    Chousou, Anna
    Perperoglou, Aris
    HEART, 2023, 109 : A101 - A102
  • [25] Embolic stroke of undetermined source correlates to atrial fibrosis without atrial fibrillation
    Tandon, Karman
    Tirschwell, David
    Longstreth, W. T., Jr.
    Smith, Bryn
    Akoum, Nazem
    NEUROLOGY, 2019, 93 (04) : E381 - E387
  • [26] Incidence of atrial fibrillation among patients with an embolic stroke of undetermined source: Insights from insertable cardiac monitors
    Verma, Nishant
    Ziegler, Paul D.
    Liu, Shufeng
    Passman, Rod S.
    INTERNATIONAL JOURNAL OF STROKE, 2019, 14 (02) : 146 - 153
  • [27] Atrial Fibrillation Risk Assessment after Embolic Stroke of Undetermined Source
    von Falkenhausen, Aenne S.
    Feil, Katharina
    Sinner, Moritz F.
    Schoenecker, Sonja
    Mueller, Johanna
    Wischmann, Johannes
    Eiffener, Elodie
    Clauss, Sebastian
    Poli, Sven
    Poli, Khouloud
    Zuern, Christine S.
    Ziemann, Ulf
    Berrouschot, Jorg
    Kitsiou, Alkisti
    Schaebitz, Wolf-Rudiger
    Dieterich, Marianne
    Massberg, Steffen
    Kaeaeb, Stefan
    Kellert, Lars
    ANNALS OF NEUROLOGY, 2023, 93 (03) : 479 - 488
  • [28] Left atrial diameter thresholds and new incident atrial fibrillation in embolic stroke of undetermined source
    Perlepe, Kalliopi
    Sirimarco, Gaia
    Strambo, Davide
    Eskandari, Ashraf
    Karagkiozi, Efstathia
    Vemmou, Anastasia
    Koroboki, Eleni
    Manios, Efstathios
    Makaritsis, Konstantinos
    Vemmos, Konstantinos
    Michel, Patrik
    Ntaios, George
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2020, 75 : 30 - 34
  • [29] Left atrial volumetric/mechanical coupling index and atrial fibrillation in the embolic stroke of undetermined source
    Mugnai, Giacomo
    Comuzzi, Alberto
    De Giovanni, Sara
    Armani, Ilaria
    Benfari, Giovanni
    Zivelonghi, Cecilia
    Bolzan, Bruna
    Capocci, Sofia
    Cappellari, Manuel
    Tomasi, Luca
    Ribichini, Flavio
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2025, 26 (01) : 58 - 61
  • [30] Detection of atrial fibrillation in patients with embolic stroke of undetermined source by prolonged monitoring with implantable loop recorders
    Israel, Carsten
    Kitsiou, Alkisti
    Kalyani, Malik
    Deelawar, Sameera
    Ejangue, Lucy Ekosso
    Rogalewski, Andreas
    Hagemeister, Christoph
    Minnerup, Jens
    Schaebitz, Wolf-Ruediger
    THROMBOSIS AND HAEMOSTASIS, 2017, 117 (10) : 1962 - 1969