Forced vibration analysis model for pumped storage power station based on the 1D-3D coupling and pipe walls vibration

被引:3
作者
Yang, Xiuwei [1 ,2 ]
Lian, Jijian [1 ,2 ]
Wang, Haijun [1 ,2 ]
Zhang, Ziliang [1 ,2 ]
Hu, Yan [1 ,2 ]
机构
[1] Tianjin Univ, State Key Lab Hydraul Engn Simulat & Safety, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
来源
EARTHQUAKE ENGINEERING AND RESILIENCE | 2022年 / 1卷 / 04期
关键词
1D-3D coupling; forced vibration analysis; OpenFOAM; pumped storage power station; water hammer; TURBINE; HYDRO;
D O I
10.1002/eer2.32
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hydraulic vibration is a common phenomenon in pumped storage power stations (PSPS) and hydropower plants. Evaluating the performance of the PSPS and water conveyance system under the hydraulic vibration condition is significant for the safety of the electric power and the PSPS system. In this study, the one-dimensional (1D) and three-dimensional (3D) coupling model for the entire PSPS system is established based on the open-source software OpenFOAM and in-house C++ codes. The coupling data exchange is realized by writing and reading files. The coupling model is validated by comparing the results with the pure 1D method under small load disturbance conditions. The forced vibration source is modeled by the pipe walls vibration method in the 3D region, and the 1D method takes charge of other parts in the PSPS system. The combination of the pipe walls vibration and 1D-3D coupling could fully consider the incident and reflected characteristics of the pressure waves. The established model could evaluate the overall performance of the PSPS system under forced vibration. Sensitive analysis of the vibration magnitude is carried out, and the results are consistent with the theoretical analysis, demonstrating that the established model is applicable for the forced vibration analysis. This study proposed a novel forced vibration model based on pipe vibration and 1D-3D coupling methods. The established model could evaluate the overall performance of the pumped storage power station system under forced vibration image
引用
收藏
页码:393 / 409
页数:17
相关论文
共 31 条
[1]  
[Anonymous], 2020, ANSYS Fluent User's Guide 2020 R2
[2]  
[Anonymous], 2009, ANSYS FLUENT Theory Guide
[3]   A new generation of small hydro and pumped-hydro power plants: Advances and future challenges [J].
Ardizzon, G. ;
Cavazzini, G. ;
Pavesi, G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 :746-761
[4]  
Duan L., 2011, Water ResourPower, V29, P4
[5]   Study of the vortex-induced pressure excitation source in a Francis turbine draft tube by particle image velocimetry [J].
Favrel, A. ;
Mueller, A. ;
Landry, C. ;
Yamamoto, K. ;
Avellan, F. .
EXPERIMENTS IN FLUIDS, 2015, 56 (12) :1-15
[6]   Effect of Sediment Concentration on Hydraulic Characteristics of Energy Dissipation in a Falling Turbulent Jet [J].
Gou, Wenjuan ;
Li, Huiping ;
Du, Yunyi ;
Yin, Hongxia ;
Liu, Fang ;
Lian, Jijian .
APPLIED SCIENCES-BASEL, 2018, 8 (09)
[7]   Hydraulic-mechanical coupling vibration performance of pumped storage power station with two turbine units sharing one tunnel [J].
Guo, Wencheng ;
Wu, Fulin .
JOURNAL OF ENERGY STORAGE, 2022, 53
[8]   Experimental Evidence of Rotating Stall in a Pump-Turbine at Off-Design Conditions in Generating Mode [J].
Hasmatuchi, Vlad ;
Farhat, Mohamed ;
Roth, Steven ;
Botero, Francisco ;
Avellan, Francois .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (05)
[9]  
Jasak H., 1996, Error analysis and estimation for finite volume method with applications to fluid flows
[10]   Reproducing oscillatory behaviour of a hydroelectric power station by computer simulation [J].
Mansoor, SP ;
Jones, DI ;
Bradley, DA ;
Aris, FC ;
Jones, GR .
CONTROL ENGINEERING PRACTICE, 2000, 8 (11) :1261-1272