Experimental study of local buckling behaviour of 7A04-T6 high strength aluminium alloy H-section stub columns in fire

被引:6
作者
Wang, Zhongxing [1 ,2 ,3 ]
Zhan, Lele [2 ]
Yun, Xiang [4 ]
机构
[1] Tianjin Univ, Key Lab Earthquake Engn Simulat & Seism Resilience, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[3] Tianjin Univ, Key Lab Coast Civil Struct Safety China, Minist Educ, Tianjin 300350, Peoples R China
[4] Univ Bristol, Dept Civil Engn, Bristol BS8 1TR, England
基金
中国国家自然科学基金;
关键词
Fire tests; High strength aluminium alloy; H -section stub columns; Local buckling; Structural design methods;
D O I
10.1016/j.engstruct.2024.118631
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a comprehensive experimental investigation into the local buckling behaviour of 7A04-T6 high strength aluminium alloy H-section stub columns in fire. The experimental programme comprises six room temperature tests and eighteen steady-state fire tests on 7A04-T6 high strength aluminium alloy H-section stub columns. In addition, complementary tensile coupon tests at room temperature and initial local geometric imperfection measurements of the stub column specimens were undertaken. The study meticulously details the test setup, procedures, instrumentation and key results, including failure modes, ultimate resistances and loadend shortening curves of the test specimens. The obtained test results are utilised to assess the applicability and accuracy of existing fire design rules outlined in European, Chinese and American standards, the design recommendations presented by Han et al. [1] and Maljaars et al. [2] for aluminium structural components in fire, as well as the recently developed deformation-based method named the Continuous Strength Method. The findings indicate that the existing design approaches provide conservative predictions of ultimate resistances for 7A04-T6 high strength aluminium alloy H-section stub columns in fire to varying degrees, highlighting the imperative need for further refinement of the design rules to enhance their predictive accuracy.
引用
收藏
页数:15
相关论文
共 40 条
[1]   PID control system analysis, design, and technology [J].
Ang, KH ;
Chong, G ;
Li, Y .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2005, 13 (04) :559-576
[2]  
[Anonymous], 2020, 7562020 TCECS
[3]  
[Anonymous], 2015, Aluminum Design Manual Part I: Specification for Aluminum Structures
[4]  
[Anonymous], 2007, GB 50429-2007
[5]  
[Anonymous], 2007, EN 1999-1-2
[6]  
[Anonymous], 2019, EN 1090-3
[7]  
[Anonymous], 2007, EN 1999-1-1
[8]  
[冯鹏 Feng Peng], 2017, [工程力学, Engineering Mechanics], V34, P36
[9]   Mechanical behavior of concrete-filled square steel tube with FRP-confined concrete core subjected to axial compression [J].
Feng, Peng ;
Cheng, Shi ;
Bai, Yu ;
Ye, Lieping .
COMPOSITE STRUCTURES, 2015, 123 :312-324
[10]   The Continuous Strength Method - Review and outlook [J].
Gardner, Leroy ;
Yun, Xiang ;
Walport, Fiona .
ENGINEERING STRUCTURES, 2023, 275