Nanomaterial Modified Screen Printed Electrode Based Electrochemical Genosensor for Efficient Detection of Neonatal Sepsis

被引:0
|
作者
Gopal, Neha [1 ,6 ]
Chauhan, Nidhi [2 ]
Jain, Utkarsh [2 ]
Dass, Sujata K. [3 ]
Chandra, Ramesh [1 ,4 ,5 ,6 ]
机构
[1] Univ Delhi, Dept Chem, Drug Discovery & Dev Lab, Delhi 110007, India
[2] UPES, Sch Hlth Sci & Technol, Dehra Dun 248007, Uttarakhand, India
[3] BLK Super Special Hosp, Dept Neurol, New Delhi 110005, India
[4] Univ Delhi, Inst Nano Med Sci, Delhi 110007, India
[5] Univ Delhi, Dr B R Ambedkar Ctr Biomed Res, Delhi 110007, India
[6] Maharaja Surajmal Brij Univ, Bharatpur 321201, Rajasthan, India
关键词
Neonatal sepsis; GBS; cfb; Electrochemical genosensor; Nanomaterials; REDUCED GRAPHENE OXIDE; GROUP-B STREPTOCOCCI; ELECTROPHORETIC DEPOSITION; IMPEDANCE SPECTROSCOPY; DEOXYRIBONUCLEIC-ACID; CHITOSAN-GRAPHENE; RAPID DETECTION; DNA BIOSENSOR; PLATFORM; SENSOR;
D O I
10.1007/s12088-024-01348-w
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The present work reports fabrication of nanomaterial based electrochemical genosensor for efficient detection of neonatal sepsis. For this purpose, virulent cfb gene of its major causative organisms, i.e. Group B Streptococcus (GBS) was selected. Further, a cfb specific 19-mer long amine terminated DNA probe was designed to be used as bioreceptor. The genosensing platform is fabricated by utilizing graphene oxide as nanomaterial which is deposited onto screen printed electrode (SPE) by electrophoretic deposition technique. Thereafter, the designed probe DNA is immobilized on graphene oxide modified SPE through EDC-NHS chemistry. Characterization of nanomaterial and fabricated genosensing platform is studied via X-ray diffraction, Scanning electron microscopy, atomic force microscopy, Fourier transmission infrared spectroscopy and cyclic voltammetry techniques. The fabricated genosensor (BSA/pDNA/GO/SPE) is able to efficiently detect target cfb gene with a linear detection range of 10(-12)-10(-7) M, lower detection limit of 10(-12) M and sensitivity of 725.9 mu A M-1 cm(-2). The biosensing ability of developed genosenor is also investigated in artificial serum sample and the obtained results are found within acceptable percentage relative standard deviation (%RSD), indicating its application in detecting neonatal sepsis in serum samples.
引用
收藏
页码:515 / 528
页数:14
相关论文
共 50 条
  • [21] Recent build outs in electroanalytical biosensors based on carbon-nanomaterial modified screen printed electrode platforms
    Jaiswal, Nandita
    Tiwari, Ida
    ANALYTICAL METHODS, 2017, 9 (26) : 3895 - 3907
  • [22] Efficient Detection of Droxidopa in the Presence of Carbidopa Using a Modified Screen-Printed Graphite Electrode
    Ahmadi, Sayed Ali
    Tajik, Somayeh
    TOPICS IN CATALYSIS, 2024, 67 (9-12) : 737 - 747
  • [23] Electrochemical determination of tramadol using modified screen-printed electrode
    Mohammadi, Sayed Zia
    Jafari, Maedeh
    Jahani, Peyman Mohammadzadeh
    Ahmadi, Sayed Ali
    Mashayekh, Raana
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 127 - 135
  • [24] A Screen-Printed Electrode Modified With Graphene/Co3O4 Nanocomposite for Electrochemical Detection of Tramadol
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Beitollahi, Hadi
    Zhang, Kaiqiang
    Van Le, Quyet
    Cha, Joo Hwan
    Jang, Ho Won
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [25] Electrochemical determination of Roxarsone using preconcentration-based signal amplification on modified screen-printed electrode
    Ferreira, Luis M. C.
    Martins, Paulo R.
    Silva, Cristiane G.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    Vicentini, Fernando C.
    FOOD CHEMISTRY, 2024, 437
  • [26] Reduced graphene oxide-yttria nanocomposite modified electrode for enhancing the sensitivity of electrochemical genosensor
    Rasheed, P. Abdul
    Radhakrishnan, Thulasi
    Shihabudeen, P. K.
    Sandhyarani, N.
    BIOSENSORS & BIOELECTRONICS, 2016, 83 : 361 - 367
  • [27] Polyaniline-chitosan modified on screen-printed carbon electrode for the electrochemical detection of perfluorooctanoic acid
    Suhaimi, Nur Farahin
    Baharin, Siti Nor Atika
    Jamion, Nurul Ain
    Zain, Zainiharyati Mohd
    Sambasevam, Kavirajaa Pandian
    MICROCHEMICAL JOURNAL, 2023, 188
  • [28] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    MATERIALS LETTERS, 2021, 304
  • [29] A novel genosensor based on Fe3O4@SiO2/DABCO-modified screen-printed graphite electrode for detection of prostate cancer gene sequence hybridization
    Abedi, Rokhsareh
    Raoof, Jahan Bakhsh
    Hashkavayi, Ayemeh Bagheri
    Asghari, Maryam
    Azimi, Razieh
    Hejazi, Mohammad Saeid
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (06) : 2631 - 2640
  • [30] Sandwich Electrochemical Immunosensor for Early Detection of Tuberculosis Based on Graphene/Polyaniline-Modified Screen-Printed Gold Electrode
    Azmi, Umi Zulaikha Mohd
    Yusof, Nor Azah
    Kusnin, Norzila
    Abdullah, Jaafar
    Suraiya, Siti
    Ong, Poh Shing
    Raston, Nurul Hanun Ahmad
    Abd Rahman, Siti Fatimah
    Fathil, Mohamad Faris Mohamad
    SENSORS, 2018, 18 (11)