Novel method for determination of colistin sulfate in human plasma by high-performance liquid chromatography-tandem mass spectrometry and its clinical applications in critically ill patients

被引:2
|
作者
Wang, Xiaoying [1 ]
Sun, Qiang [1 ]
Li, Xiaojing [1 ]
Wang, Genzhu [1 ]
Xing, Baiqian [1 ]
Li, Zhongdong [1 ]
机构
[1] Capital Med Univ Elect Teaching Hosp, Beijing Elect Power Hosp State Grid Co China, Dept Pharm, Beijing 100073, Peoples R China
关键词
Colistin; Colistin sulfate; LC-MS/MS; Plasma; Therapeutic drug monitoring; PHARMACOKINETICS; NEPHROTOXICITY; VALIDATION; URINE; MS/MS;
D O I
10.1016/j.vascn.2024.107502
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Colistin is a last-resort antibiotic used for treating infections caused by carbapenem-resistant Gram-negative bacteria, particularly in critically patients, nevertheless its therapeutic window is narrow, and requires monitoring. A determination method suitable for clinical detection is conducive to ensure its efficacy and safety of patients with severe infection. We developed and validated a concise and accurate high-performance liquid chromatography-tandem mass spectrometry method for the determination of colistin A and B in human plasma. We used a Kinetex C18 column (50 mm x 2.1 mm, 2.6 mu m) with acetonitrile (containing 0.1% formic acid) as the protein precipitant and water (containing 0.2% formic acid and 5 mmol/L ammonium formate) - acetonitrile (containing 0.2% formic acid) as the gradient elution. The calibration curves were linear over concentration ranges of 0.06-4.00 mu g/mL (colistin A) and 0.1-7.0 mu g/mL (colistin B). The precision, accuracy, matrix effect, extraction recovery, and stability were all validated. This method was applied to the therapeutic drug monitoring for 50 critically ill patients. The trough, peak, and average steady-state concentrations of these patients were 0.8 +/- 0.4, 1.4 +/- 0.5, and 1.0 +/- 0.4 mu g/mL, respectively. And the concentrations of colistin in human plasma were closely related to the patient's renal function.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Bihan, Kevin
    Lu, Qin
    Enjalbert, Manon
    Apparuit, Maxime
    Langeron, Olivier
    Rouby, Jean-Jacques
    Funck-Brentano, Christian
    Zahr, Noel
    THERAPEUTIC DRUG MONITORING, 2016, 38 (06) : 796 - 803
  • [2] Simultaneous determination of colistin sulfate and tigecycline in human plasma by liquid chromatography-tandem mass spectrometry method
    Ma, Ying-Chao
    Wu, Xi-Kun
    Yang, Xiu-Ling
    Zhang, Zhi-Qing
    BMC CHEMISTRY, 2024, 18 (01)
  • [3] Simultaneous determination of colistin sulfate and tigecycline in human plasma by liquid chromatography-tandem mass spectrometry method
    Ying-Chao Ma
    Xi-Kun Wu
    Xiu-Ling Yang
    Zhi-Qing Zhang
    BMC Chemistry, 18
  • [4] A high-performance liquid chromatography-tandem mass spectrometry method for the determination of artemether and dihydroartemisinin in human plasma
    Hilhorst, M. J.
    Hendriks, G.
    de Vries, R.
    Hillewaert, V.
    Verhaege, T.
    van de Merbelac, N. C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 45 - 53
  • [5] Determination of Escitalopram in Human Plasma by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    de Sousa, Carlos E. M.
    Bonifacio, Felipe N.
    Bedor, Danilo C. G.
    Silva, Thayse M.
    Ramos, Virna L. S.
    de Souza Filho, Jose H.
    Leal, Leila B.
    Oliveira, Amanda T. C.
    de Santana, Davi P.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 310 - 314
  • [6] Determination of repaglinide in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Jie
    Gao, Feng
    Guan, Xin
    Sun, Yan-tong
    Gu, Jing-kai
    Fawcett, J. Paul
    ACTA PHARMACEUTICA SINICA B, 2011, 1 (01) : 40 - 45
  • [7] Determination of beraprost in human plasma by a high-performance liquid chromatography-tandem mass spectrometry
    Lee, J.
    Kim, H.
    Jeong, J. C.
    Park, E. S.
    Hwang, K. W.
    Yang, S. J.
    Jeong, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (02): : 229 - 233
  • [8] Determination of ecabet in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Dan
    Du, Xiaolin
    Liu, Mingyuan
    Li, Hao
    Jiang, Yao
    Zhao, Limei
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (02): : 223 - 228
  • [9] High-performance liquid chromatography with fluorescence detection method for measuring colistin in human serum and its application in critically ill patients treated with colistin methanesulfonate sodium
    Zabidi, Mohd Shafie
    Bakar, Ruzilawati Abu
    Musa, Nurfadhlina
    Mustafa, Suzana
    Ismail, Wan Nasrudin Wan
    Manap, Siti Nur Aziela Ab
    Zaid, Nur Aishah Che Mohd
    Yusuf, Wan Nazirah Wan
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2023, 46 (16-20) : 282 - 292
  • [10] Determination of eupatilin in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Kim, IK
    Kim, SH
    Kim, WB
    Lee, HS
    CHROMATOGRAPHIA, 2004, 59 (7-8) : 425 - 428