High-Sensitivity Curvature Fiber Sensor Based on Miniature Two-Path Mach-Zehnder Interferometer

被引:1
|
作者
Wu, Yue [1 ]
Liu, Yu [1 ]
Zhuang, Haoran [1 ]
Cao, Juan [1 ]
Yang, Yongjie [1 ]
Zhu, Xiaojun [2 ]
Sun, Dan [3 ]
Shi, Yuechun [4 ]
Tao, Rumao [5 ]
机构
[1] Nantong Univ, Sch Informat Sci & Technol, Nantong 226019, Peoples R China
[2] Nantong Univ, Sch Microelect, Nantong 226019, Peoples R China
[3] Peking Univ, Yangtze Delta Inst Optoelect, Nantong 226019, Peoples R China
[4] Yongjiang Lab, Ningbo 315202, Peoples R China
[5] China Acad Engn Phys, Laser Fus Res Ctr, Mianyang 621900, Peoples R China
关键词
curvature sensing; miniature two-path; Mach-Zehnder interferometer;
D O I
10.3390/mi15080963
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper introduces a new high-sensitivity curvature fiber sensor based on a miniature two-path Mach-Zehnder interferometer (MTP-MZI). The sensor is fabricated by coupling and fusing the multimode fiber (MMF) with the single-mode fiber (SMF) using arc fusion technology (AFT), resulting in a centimeter-level two-path MZI structure. The sensor represents an innovative approach to MZI coupling technology, which reduces device size, simplifies manufacturing, and lowers costs. In curvature-sensing experiments, the MTP-MZI sensor achieves a maximum curvature sensitivity of -96.70 dB/m-1 in the curvature range of 0.0418 m-1 to 0.0888 m-1, which is an extremely high sensitivity among intensity-modulated curvature sensors. Additionally, temperature-sensing measurements of the MTP-MZI sensor show a maximum temperature sensitivity of 212 pm/degrees C in the range of 30 degrees C to 70 degrees C, which is low temperature sensitivity and solves the cross-sensitivity problem. Thanks to the miniature two-path structure of the MTP-MZI, it provides a new perspective for developing multidimensional and multiparameter measurement methods in MZI fiber sensors.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] High sensitivity inline fiber Mach-Zehnder interferometer bend sensor using a twin core fiber
    Harhira, Aissa
    Lapointe, Jerome
    Kashyap, Raman
    FOURTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2010, 7653
  • [32] High-Sensitivity Liquid-Level Sensor Based on Mach-Zehnder Interferometer With a Side-Polished Structure
    He, Xuelan
    Zhang, Chuang
    Xing, Jian
    IEEE SENSORS JOURNAL, 2024, 24 (21) : 34598 - 34603
  • [33] Dual Mach-Zehnder Interferometer Based on Side-Hole Fiber for High-Sensitivity Refractive Index Sensing
    Hu, Jie
    Shao, Liyang
    Gu, Guoqiang
    Zhang, Xuming
    Liu, Yanjun
    Song, Xuefeng
    Song, Zhangqi
    Feng, Jiansong
    Buczynski, Ryszard
    Smietana, Mateusz
    Wang, Taihong
    Lang, Tingting
    IEEE PHOTONICS JOURNAL, 2019, 11 (06):
  • [34] All-Fiber high-sensitivity temperature sensor based on Mach-Zehnder interferometer with a little lateral-offset splicing for seawater
    Liu, Ruijie
    Lv, Riqing
    Lin, Ziting
    Zhao, Jincheng
    Zheng, Hongkun
    Cai, Lu
    Zhao, Yong
    MEASUREMENT, 2025, 247
  • [35] Fiber-optic Mach-Zehnder interferometric sensor for high-sensitivity high temperature measurement
    Liu, Yun
    Peng, Wei
    Liang, Yuzhang
    Zhang, Xinpu
    Zhou, Xinlei
    Pan, Lujun
    OPTICS COMMUNICATIONS, 2013, 300 : 194 - 198
  • [36] High-Sensitivity Humidity Sensor Based on Microknot Resonator Assisted Agarose-Coated Mach-Zehnder Interferometer
    Yi, Yating
    Jiang, Yuxuan
    Zhao, Haiyan
    Brambilla, Gilberto
    Fan, Yaxian
    Wang, Pengfei
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (07) : 2191 - 2196
  • [37] Characteristics of bend sensor based on two-notch Mach-Zehnder fiber interferometer
    Miao, Yinping
    Zhang, Kailiang
    Liu, Bo
    Lin, Wei
    Yao, Jianquan
    OPTICAL FIBER TECHNOLOGY, 2012, 18 (06) : 509 - 512
  • [38] Asymmetrical in-fiber Mach-Zehnder interferometer for curvature measurement
    Sun, Bing
    Huang, Yijian
    Liu, Shen
    Wang, Chao
    He, Jun
    Liao, Changrui
    Yin, Guolu
    Zhao, Jing
    Liu, Yinjie
    Tang, Jian
    Zhou, Jiangtao
    Wang, Yiping
    OPTICS EXPRESS, 2015, 23 (11): : 14596 - 14602
  • [39] High sensitivity magnetic field sensor based on a Mach-Zehnder interferometer and magnetic fluid
    Zeng, Li
    Sun, Xiaoyan
    Zhang, Limu
    Hu, Youwang
    Duan, Ji'an
    OPTIK, 2022, 249
  • [40] High-pressure sensor based on fiber in-line Mach-Zehnder interferometer
    Talataisong, W.
    Wang, D. N.
    Chitaree, R.
    Liao, C. R.
    Wang, C.
    24TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2015, 9634